Smiths detection HI-SCAN 5170-A User Manual page 107

Conventional x-ray inspection units hi-scan with hitrax electronics
Table of Contents

Advertisement

Error messages
Error code: 0014
Object inside tunnel or signal deviation of a detector
line! Convey object out of tunnel or switch off X-ray
unit and remove object manually!
A
Warning!
Switch off the X-ray unit before starting any of
R
the following work and remove the key! If the
unit does not have a key switch, wait until all
indicators on the keyboard have extinguished
and separate the unit from the mains by
pulling the mains plug!
Error code: 0018
Operating conditions out of range! Scanning disabled!
Error code: 0027
X-ray system (A/B/...) cannot be activated (operating
conditions are possibly out of range)!
Error code: 0028
X-ray system (A/B/...) cannot be deactivated! Switch
off unit immediately!
Error code: 0029
Unexpected activation of X-ray system (A/B/...)!
Switch off unit immediately!
95587412 01/01/09 © Smiths Heimann
Cause/Correction
 When clearing the tunnel after switching on the
X-ray unit, ensure that no baggage or freight
items are placed on the conveyors while the con-
veyors are running.
 Check if there is still a baggage item inside the
inspection tunnel and remove it by hand.
 If there is no item in the tunnel, you should ask
the local service office or Smiths Heimann to do
the repair, because image errors must be taken
into consideration due to the signal deviation.
1220
 The temperature is too high or too low. See to a
lower or higher ambient temperature to be estab-
lished.
 On units equipped with a heating or cooling sys-
tem* for the X-ray generators, the correct operat-
ing conditions will be automatically established
after a short time.
 Due to a hardware failure the X-radiation does not
switch off anymore.
A
Warning!
Switch off the X-ray unit at once! If the error
R
returns after switching on again or if the er-
ror 0029 (Unexpected activation of X-ray sys-
tem!) occurs, withdraw the key or the mains
cable and have the unit repaired! Further op-
eration of the X-ray unit is not permitted!
 Due to a hardware failure X-radiation switches on
by itself.
A
Warning!
Therefore switch off the X-ray unit at once! If
R
the error returns after having switched on
again, withdraw the key or the mains cable
and have the unit repaired! Further operation
of the X-ray unit is not permitted!
How to correct operating troubles
1230
1240
1-97

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI-SCAN 5170-A and is the answer not in the manual?

Questions and answers

Suranjan Kumar Saha
March 26, 2025

Power switch of key board in II position meaning

Tracy T Carter
April 17, 2025

login code for 4060i

ISHWER SINGH
April 21, 2025

Hyy teem 0509 code ke aane ke karna mera key board ki key kaam nhi krr rhi jis karn me X-ray operating nhi krr parha hu

User image 680690c1f0236
Nur Talantbek kyzy
April 23, 2025

Hi. This msg shows: X ray generating system can not activated, operating condition are possibly out of range. Error code 0027 Please advise

Table of Contents

Save PDF