Indoor units: 7,000 Btu + 7,000 Btu
°FDB
64
°FWB
54
TC
SHC
IP
°FDB
kBtu/h
kW
14
12.74
10.15
0.51
14.40
23
12.21
9.90
0.58
13.80
32
12.00
9.80
0.64
13.56
41
11.89
9.75
0.66
13.44
50
12.00
9.80
0.67
13.56
59
11.68
9.65
0.69
13.20
67
14.52
10.99
1.01
16.41
77
13.93
10.69
1.04
15.74
87
13.07
10.26
1.15
14.77
95
13.64
10.56
1.53
15.42
104
12.94
10.24
1.70
14.62
115
12.00
9.93
1.83
13.57
°CDB
17.8
°CWB
12.2
TC
SHC
IP
°CDB
kW
-10.0
3.73
2.97
0.51
4.22
-5.0
3.58
2.90
0.58
4.04
0.0
3.52
2.87
0.64
3.97
5.0
3.49
2.86
0.66
3.94
10.0
3.52
2.87
0.67
3.97
15.0
3.42
2.83
0.69
3.87
19.4
4.26
3.22
1.01
4.81
25.0
4.08
3.13
1.04
4.61
30.6
3.83
3.01
1.15
4.33
35.0
4.00
3.09
1.53
4.52
40.0
3.79
3.00
1.70
4.28
46.1
3.52
2.91
1.83
3.98
Indoor units: 7,000 Btu + 9,000 Btu
°FDB
64
°FWB
54
TC
SHC
IP
°FDB
kBtu/h
kW
14
14.66
11.33
0.64
16.57
23
14.05
11.05
0.72
15.88
32
13.81
10.94
0.80
15.60
41
13.68
10.89
0.82
15.46
50
13.81
10.94
0.83
15.60
59
13.44
10.77
0.86
15.19
67
15.48
11.74
1.07
17.49
77
14.85
11.41
1.09
16.78
87
13.93
10.95
1.21
15.75
95
15.52
11.71
1.70
17.54
104
14.75
11.37
1.89
16.67
115
12.19
10.43
1.86
13.77
°CDB
17.8
°CWB
12.2
TC
SHC
IP
°CDB
kW
-10.0
4.30
3.32
0.64
4.86
-5.0
4.12
3.24
0.72
4.65
0.0
4.05
3.21
0.80
4.57
5.0
4.01
3.19
0.82
4.53
10.0
4.05
3.21
0.83
4.57
15.0
3.94
3.16
0.86
4.45
19.4
4.54
3.44
1.07
5.13
25.0
4.35
3.35
1.09
4.92
30.6
4.08
3.21
1.21
4.61
35.0
4.55
3.43
1.70
5.14
40.0
4.32
3.33
1.89
4.89
46.1
3.57
3.06
1.86
4.04
70
75
60
63
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
10.14
0.52
15.18
11.18
9.89
0.59
14.55
10.91
9.79
0.65
14.30
10.80
9.74
0.67
14.17
10.74
9.79
0.68
14.30
10.80
9.64
0.71
13.92
10.63
10.98
1.03
17.30
12.11
10.67
1.06
16.60
11.77
10.24
1.17
15.57
11.30
10.54
1.56
16.25
11.63
10.22
1.73
15.41
11.28
9.92
1.87
14.30
10.94
21.1
23.9
15.6
17.2
TC
SHC
IP
TC
SHC
kW
kW
2.97
0.52
4.45
3.28
2.90
0.59
4.26
3.20
2.87
0.65
4.19
3.16
2.85
0.67
4.15
3.15
2.87
0.68
4.19
3.16
2.82
0.71
4.08
3.12
3.22
1.03
5.07
3.55
3.13
1.06
4.86
3.45
3.00
1.17
4.56
3.31
3.09
1.56
4.76
3.41
3.00
1.73
4.52
3.31
2.91
1.87
4.19
3.21
70
75
60
63
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
11.32
0.65
17.47
12.48
11.04
0.73
16.74
12.18
10.93
0.81
16.45
12.06
10.87
0.83
16.30
11.99
10.93
0.84
16.45
12.06
10.76
0.87
16.01
11.87
11.73
1.09
18.44
12.94
11.40
1.11
17.69
12.57
10.94
1.24
16.60
12.07
11.70
1.73
18.49
12.90
11.36
1.92
17.58
12.53
10.41
1.90
14.52
11.49
21.1
23.9
15.6
17.2
TC
SHC
IP
TC
SHC
kW
kW
3.32
0.65
5.12
3.66
3.24
0.73
4.91
3.57
3.20
0.81
4.82
3.53
3.19
0.83
4.78
3.52
3.20
0.84
4.82
3.53
3.15
0.87
4.69
3.48
3.44
1.09
5.40
3.79
3.34
1.11
5.18
3.69
3.21
1.24
4.86
3.54
3.43
1.73
5.42
3.78
3.33
1.92
5.15
3.67
3.05
1.90
4.25
3.37
- 190 -
Indoor temperature
80
67
IP
TC
SHC
IP
TC
kW
kBtu/h
kW
0.53
16.25
11.73
0.53
17.38
0.60
15.58
11.45
0.60
16.65
0.66
15.31
11.33
0.67
16.36
0.68
15.17
11.27
0.68
16.22
0.68
15.31
11.33
0.69
16.36
0.71
14.90
11.16
0.72
15.93
1.04
18.53
12.71
1.05
19.80
1.06
17.77
12.35
1.08
19.00
1.18
16.68
11.86
1.19
17.83
1.57
17.40
12.21
1.59
18.60
1.74
16.50
11.84
1.76
17.64
1.88
15.31
11.48
1.90
16.37
Indoor temperature
26.7
19.4
IP
TC
SHC
IP
TC
kW
0.53
4.76
3.44
0.53
5.09
0.60
4.57
3.35
0.60
4.88
0.66
4.49
3.32
0.67
4.80
0.68
4.45
3.30
0.68
4.75
0.68
4.49
3.32
0.69
4.80
0.71
4.37
3.27
0.72
4.67
1.04
5.43
3.73
1.05
5.80
1.06
5.21
3.62
1.08
5.57
1.18
4.89
3.48
1.19
5.22
1.57
5.10
3.58
1.59
5.45
1.74
4.84
3.47
1.76
5.17
1.88
4.49
3.36
1.90
4.80
Indoor temperature
80
67
IP
TC
SHC
IP
TC
kW
kBtu/h
kW
0.65
18.70
13.10
0.66
19.99
0.74
17.92
12.78
0.75
19.16
0.82
17.61
12.65
0.83
18.82
0.84
17.45
12.59
0.85
18.66
0.85
17.61
12.65
0.86
18.82
0.88
17.14
12.45
0.89
18.32
1.10
19.74
13.58
1.11
21.11
1.12
18.94
13.20
1.13
20.24
1.25
17.77
12.66
1.26
19.00
1.75
19.80
13.54
1.77
21.17
1.94
18.82
13.15
1.96
20.12
1.91
15.54
12.06
1.93
16.61
Indoor temperature
26.7
19.4
IP
TC
SHC
IP
TC
kW
0.65
5.48
3.84
0.66
5.86
0.74
5.25
3.75
0.75
5.61
0.82
5.16
3.71
0.83
5.52
0.84
5.12
3.69
0.85
5.47
0.85
5.16
3.71
0.86
5.52
0.88
5.02
3.65
0.89
5.37
1.10
5.79
3.98
1.11
6.19
1.12
5.55
3.87
1.13
5.93
1.25
5.21
3.71
1.26
5.57
1.75
5.80
3.97
1.77
6.20
1.94
5.52
3.85
1.96
5.90
1.91
4.56
3.53
1.93
4.87
85
90
71
73
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
12.00
0.54
17.91
13.34
11.71
0.61
17.17
13.02
11.59
0.67
16.87
12.88
11.53
0.69
16.72
12.82
11.59
0.70
16.87
12.88
11.41
0.73
16.42
12.68
13.00
1.06
20.42
14.45
12.64
1.09
19.58
14.05
12.13
1.21
18.38
13.48
12.49
1.60
19.17
13.88
12.11
1.78
18.18
13.46
11.74
1.92
16.87
13.05
29.4
32.2
21.7
22.8
SHC
IP
TC
SHC
kW
kW
3.52
0.54
5.25
3.91
3.43
0.61
5.03
3.81
3.40
0.67
4.94
3.78
3.38
0.69
4.90
3.76
3.40
0.70
4.94
3.78
3.35
0.73
4.81
3.72
3.81
1.06
5.98
4.24
3.70
1.09
5.74
4.12
3.56
1.21
5.39
3.95
3.66
1.60
5.62
4.07
3.55
1.78
5.33
3.94
3.44
1.92
4.95
3.83
85
90
71
73
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
13.40
0.67
20.61
14.89
13.08
0.76
19.75
14.53
12.94
0.84
19.40
14.38
12.88
0.86
19.23
14.31
12.94
0.87
19.40
14.38
12.74
0.90
18.89
14.16
13.89
1.12
21.76
15.44
13.50
1.15
20.87
15.00
12.96
1.27
19.58
14.40
13.85
1.79
21.82
15.40
13.45
1.98
20.74
14.95
12.33
1.96
17.13
13.71
29.4
32.2
21.7
22.8
SHC
IP
TC
SHC
kW
kW
3.93
0.67
6.04
4.37
3.83
0.76
5.79
4.26
3.79
0.84
5.69
4.22
3.77
0.86
5.64
4.19
3.79
0.87
5.69
4.22
3.73
0.90
5.54
4.15
4.07
1.12
6.38
4.52
3.96
1.15
6.12
4.40
3.80
1.27
5.74
4.22
4.06
1.79
6.39
4.51
3.94
1.98
6.08
4.38
3.61
1.96
5.02
4.02
IP
kW
0.54
0.61
0.68
0.70
0.70
0.73
1.07
1.09
1.21
1.61
1.79
1.93
IP
0.54
0.61
0.68
0.70
0.70
0.73
1.07
1.09
1.21
1.61
1.79
1.93
IP
kW
0.67
0.76
0.84
0.86
0.87
0.91
1.13
1.15
1.28
1.80
1.99
1.97
IP
0.67
0.76
0.84
0.86
0.87
0.91
1.13
1.15
1.28
1.80
1.99
1.97