Whirlpool UK Appliances
ERROR CODES & POSSIBLE CAUSES
Service Manual UK
Possible Causes
Motor triac short circuit: Check motor and module
F01
connections
Motor jammed / tacho detached: Check motor and
F02
module connections
NTC short/open circuit: Check thermistor and
F03
module connections
Pressure switch jammed on empty: Check switch
F04
and module
Pressure switch jammed on full or pump blocked:
F05
Check pump and switch
F06 N/A
Heater relay stuck: Check heater and module
F07
connections
Heater relay stuck: Check pressure switch, heater
F08
and module connections
F09 Setup error: Check Eeprom
Pressure switch not sensing: Check switch and
F10
module connections
Pump cannot be activated: Check pump,
F11
connections and wiring
No communication between cards: Check module
F12
connections
Door lock error: Check door, door lock and
F17
module connections
Communication error (3 phase motor): Replace
F18
power board
Fan Motor: Check connections/open/short circuit
Dryer element
F19
Fan turns freely (not blocked)
Replace power board