Jackson Systems Z-600 Installation And Operation Manual

Six zone comfort system

Advertisement

ZONE CONTROL MADE SIMPLE™
Z-600 Six Zone Comfort System™
READ THIS MANUAL THOROUGHLY BEFORE PROCEEDING WITH INSTALLATION
INTRODUCTION
The Z-600 Comfort System™ is a residential and light commercial forced air zone control system that allows a
single HVAC unit to have up to six separate zones. The system can be expanded to as many as 12 zones by
adding 3-zone expansion modules. Intuitive firmware allows the panel to be used with single stage, multi-stage,
heat pump and dual fuel equipment having up to 3 stages of heating and 2 stages of cooling. Standard heat / cool
or heat pump thermostats can be used with the Z-600, along with a choice of two or three-wire zone dampers.
Simple slide switch configuration allows for a wide range of system setup and control options best suited for each
zoning application. Additional features include, fuse protected inputs and outputs, easy-to-read and access wiring
terminals, LED status indication of all system functions, time delay override, adjustable on-board limits, balance
point controls, and selectable ventilation and purge modes. An adjustable upstage timer allows single stage
thermostats to be used with multi-stage equipment. Capacity Control can also stage equipment based on the
number of zones calling. The Z-600 comes in an attractive and rugged 2-piece anodized aluminum enclosure that
provides easy access for wiring, system setup and diagnostics.
WARNING
1. Turn power off to HVAC unit and control panel during installation to prevent serious injury from electrical shock
and/or damage to system.
2. Use extreme care when making duct openings and handling sheet metal to avoid injury.
3. The Z-600 and all components must be installed in a conditioned space where the ambient temperature will not
exceed 150°F.
4. Install all components in a manner that prevents access by children.
CAUTION
1. Installation of this system must be in compliance with all applicable codes.
2. HVAC system must be properly sized and balanced to assure optimum system performance.
3. A bypass damper must be installed to maintain proper system airflow and static pressure.
4. All low voltage wire must be 18 gauge or heavier.
5. All wiring should be color coded and tagged for proper identification.
6. When landing wires to the control panel make sure wires are snug but do not over-tighten screw terminals.
CONTROL PANEL MOUNTING
Mount the zone control panel on a flat, moisture-free surface in a conditioned space that will facilitate easy access
for wiring and system setup.
CONTROL PANEL TRANSFORMER
1. Never use the 24 volt equipment transformer to power the control panel, regardless of it VA rating.
2. Wire a separate 24 VAC transformer of the proper VA to the designated terminals on the zone control panel
marked 24 VAC.
INSTALLATION
OPERATION MANUAL
SYSTEMS
AND

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z-600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Jackson Systems Z-600

  • Page 1 3 stages of heating and 2 stages of cooling. Standard heat / cool or heat pump thermostats can be used with the Z-600, along with a choice of two or three-wire zone dampers.
  • Page 2: Installation

    REMOTE SENSORS Z-600-DAS 1. Mount the Z-600-DAS Discharge Air Sensor in the supply trunk. Mount the sensor out of the line of sight of the heat exchanger and cooling coils whenever possible and before any zone dampers. The Z-600-DAS sensor has a resistance value of 10,000 Ohms @ 77°...
  • Page 3: Sequence Of Operation

    4 AMP PC BOARD ● PC BOARD FUSE 24 VAC 4 AMP ● TRANSFORMER NOT USED ● INPUT ZONE ● Jackson Systems PC D OPEN ● W3/AUX Z-600 ● ● PC D ● TIME DELAY ● SPEED UP PC D ●...
  • Page 4: System Setup

    120° for heat pump. Allows fan to run but shuts off or down-stages equipment to prevent overheating. Low Limit (Z-600-DAS Sensor) - Adjustable from 40° to 58° for both heat pump systems and conventional air con- ditioning. Allows fan to run but shuts off or down-stages equipment to prevent the coil from freezing.
  • Page 5 Z-600 TYPICAL THERMOSTAT WIRING DIAGRAMS W3/AUX W3/AUX SINGLE STAGE 1H/1C MULTI-STAGE 2H/2C W3/AUX W3/AUX HEAT PUMP WITH HEAT PUMP WITH NO AUXILIARY HEAT 1H/1C AUXILIARY HEAT 2H/1C W3/AUX W3/AUX MULTI-STAGE HEAT PUMP WITH MULTI-STAGE HEAT PUMP WITH NO AUXILIARY HEAT 2H/2C AUXILIARY HEAT 3H/2C IF HEAT PUMP THERMOSTAT HAS AN ‘E’...
  • Page 6 PANEL FUSES: 4 AMP PC Board Fuse The 4 AMP PC board fuse is designed to protect the Z-600 panel, zone thermostats and zone dampers from a 24 Volt short. Replacement fuse should not exceed 4 AMPS. 2 AMP System Fuses The two, RC and RH 2 AMP system fuses are designed to protect the Z-600 panel from a 24 Volt HVAC equipment short.

Table of Contents