Fujitsu ASU7RLF1 Service Instructions Manual page 41

Split type room air conditioner compact wall mounted / wall mounted / floor compact cassette / slim duct inverter multi
Hide thumbs Also See for ASU7RLF1:
Table of Contents

Advertisement

Trouble shooting 6
INDOOR UNIT Error Method:
Manual Auto Switch Error
Detective Actuators:
Indoor Unit Controller PCB
Indicator PCB
Manual Auto Switch
Forecast of Cause :
1. Manual Auto Switch failure
Check Point 1 : Check the Manual Auto Switch
Check if Manual Auto Switch is kept pressed.
Check ON/OFF switching operation by using a meter.
>> If Manual Auto Switch is disabled (on/off switching), replace it.
OK
OK
Check Point 2 : Replace Controller PCB and Indicator PCB
If Check Point 1 do not improve the symptom, replace Controller PCB and Indicator PCB.
Indicate or Display:
Outdoor Unit : No indication
Indoor Unit
: Operation lamp: 3 time Flash, Timer lamp: 5 time Flash
Economy lamp: Continuous flash.
ERROR CODE : [E : 35]
Detective details:
When the Manual Auto Switch becomes ON for consecutive 60 or
more seconds.
2. Controller PCB and Indicator PCB failure
02-09