Important Please pay particular attention. Taste Press the key. Text, Display contents Text or symbol is shown on the display. Testo-Direct info@Testo-Direct.ca 1.800.868.7495 www.
5.2 Setting the meter ................25 5.3 Measuring ..................29 5.4 Calibration ..................31 6. Care and Maintenance............32 6.1 Changing the battery ................32 6.2 Microphone ..................32 6.3 Meter ....................32 7. Technical Data ..............33 8. Accessories and Spare Parts ..........34 9. Measurement Engineering Fundamentals......35 Testo-Direct info@Testo-Direct.ca 1.800.868.7495 www.
Carry out only the maintenance and repair work that is described in the Instruction Manual. Follow the prescribed steps exactly. For safety reasons, use only original spare parts from Testo. Warranty claims will no longer apply if the meter is handled improperly or force is applied.
2. Intended Purpose 2. Intended Purpose testo 816 is a sound meter with the sound level measurement ranges 30-80dB, 50-100dB and 80-130dB, automatic range switchover, two time weightings, two frequency weightings, a maximum/minimum function, display light and a tripod screw.
(rear) button AC/DC output Calibration screw 8V input Testo-Direct 3.2 Supply voltage info@Testo-Direct.ca 1.800.868.7495 www. Voltage is supplied by a 9V block battery Type 006 P or IEC6F22 or NEDA 1604 (included). If a battery is not inserted, it is possible...
Sets weighting Level Switches over 30 to 80dB measurement range 50 to100dB 80 to 130dB 30 to 130dB (Auto range) Hold function Switches on MAX / MIN Max Hold/Min Hold Function Light Switches on display light On/Off Testo-Direct info@Testo-Direct.ca 1.800.868.7495 www.
Page 8
C is used. If the displayed value is considerably higher during the C weighting than during the A weighting, the level of low frequency noise is high. Testo-Direct info@Testo-Direct.ca 1.800.868.7495 www.
Page 9
Level: The testo 816 sound level meter covers the range 30 to 130 dB. The measurement ranges 30 to 80, 50 to 100 and 80 to 130 dB are available as well as an Auto Range function. The meter is in the middle measurement range 50 to 100 dB when first switched on.
Page 10
A clock symbol then does not appear in the display. AC/DC output The testo 816 meter has an AC/DC output with the following specifications: AC: 1 V RMS at end-scale deflection Output impedance approx. 100 Ohm Output signal through standard 3,5mm jack connector (see figure below).
5. Operation Mains connection The testo 816 meter has an 8V mains connection for use with a mains unit (see Ordering data) 5.3 Measuring Sound waves can be reflected off walls, ceilings and other objects. Also the meter housing and the person measuring (if measuring incorrectly) are disturbing factors in the sound field and can lead to incorrect measurement results.
Page 12
5. Operation Absolute pressure dependency testo 816 is calibrated by default for measurements at a height of 0 m above sea level. Measurements at other heights give rise to measurement errors which can be corrected using a table (see technical data). Subtract the appropriate offset value from the value measured (e.g.
In order to check accuracy, recalibration with the calibrator is recommended particularly if the instrument has not been used for a long period of time. The testo 816 meter should also be checked with the calibrator prior to and following...
Please contact our service department if the microphone is defect. 6.3 Meter testo 816 is maintenance-free and is therefore not bound by any maintenance intervals. Clean the housing with a damp cloth. Weak household cleaning agents can be used. Never clean with abrasive cleaning agents or solutions.
In this way, a level increase of 20 dB corresponds to a 10- fold increase in pressure. A sound level meter to EN 60651 measures the frequency weighted actual value of the sound level, it is a measure of the total sound energy converted during measurement time. Testo-Direct info@Testo-Direct.ca 1.800.868.7495 www.
Need help?
Do you have a question about the 816 and is the answer not in the manual?
Questions and answers