Page 1
Alféa Extensa Duo A.I. U0602594_1873_EN_3 06/09/2017 Air/water heat pump split 2 services Outdoor unit Hydraulic unit WOYA 060 LFCA 024127 WOYA 080 LFCA 024128 WOYA 100 LFTA Installation and commissioning instructions for professionals to be kept by the user for future reference...
Alféa Extensa Duo A.I. Heat Pump " Installation " Hydraulic connections and maintenance regulations The connection must comply with industry standard practice according to current regulations. The appliance must be installed and maintained by an approved professional in accordance with current Remember: Seal everything when fitting in accordance regulations and codes of practice.
Page 3
Alféa Extensa Duo A.I. Heat Pump " Electrical connections • General remarks on electrical connections It is essential to maintain neutral-phase polarity when • Before any maintenance operation, ensure that making electrical connections. the general power supply is switched off. Rigid wires are preferable for fixed installations, •...
Alféa Extensa Duo A.I. Heat Pump This appliance must be installed by qualified personnel holding a certificate of competence in the handling of refrigerants. Contents Description of the equipment ......6 Packing .
Page 5
Alféa Extensa Duo A.I. Heat Pump Controller Menu ....... . 50 Menu Structure .
Alféa Extensa Duo A.I. Heat Pump 1 Description of the equipment Packing Definitions - Split: The heat pump consists of two elements • 1 package: Outdoor unit. (an outdoor unit to be installed outdoors and a hydraulic • 1 package: Hydraulic unit and outside temperature unit to be installed inside the dwelling).
Alféa Extensa Duo A.I. Heat Pump General characteristics Model name Alféa Extensa Duo A.I. Rated heating performances (outdoor temp. / flow temp.) Heat output +7°C/+35°C - Underfloor heating system 4.50 6.00 7.50 10.00 -7°C/+35°C - Underfloor heating system 4.10 4.60 5.70 7.40 +7°C/+45°C - LT radiator...
Page 8
Alféa Extensa Duo A.I. Heat Pump " Outdoor Unit, Alféa Extensa Duo A.I. 5, 6 and 8 4 holes 4 holes Ø11 " Outdoor Unit, Alféa Extensa Duo A.I. 10 figure 1 - Dimensions in mm - 8 - Installation and Operating Manual "1873- EN"...
Page 9
Alféa Extensa Duo A.I. Heat Pump " Hydraulic unit Heating return. Heating flow. Back view Side view Front view Space requirements of the hydraulic unit, see figure 15, page 20. figure 2 - Dimensions in mm Dielectric connections for connections to the DCW pipes DHW circuit Gaskets...
Page 10
Alféa Extensa Duo A.I. Heat Pump Variable pressure Constant pressure 1 mbar = 10 mmCE = 100 Pa 1 mbar = 10 mmCE = 100 Pa m /h m /h figure 5 - Available hydraulic pressures and flow rates HP return sensor. Outside sensor QAC34 HP flow sensor.
Alféa Extensa Duo A.I. Heat Pump Operating principle The heat pump transmits the energy contained in the • Control functions surrounding air into the dwelling to be heated and for - The heating circuit's flow temperature is controlled by production of domestic hot water. the temperature control.
Page 15
Alféa Extensa Duo A.I. Heat Pump • Domestic hot water (DHW) operating principle Two domestic hot water (DHW) temperatures can be If the contract signed with the energy provider includes a day/night tariff, the electrical backup is subject to the set: comfort and reduced.
Alféa Extensa Duo A.I. Heat Pump 2 Installation Installation of refrigeration connections Bend the pipes into position and make holes " for them through the floor or walls either with their protective caps in place or after brazing. " Keep the protective caps in place or ends brazed until the appliance is commissioned.
Page 17
Alféa Extensa Duo A.I. Heat Pump Installation and Operating Manual "1873- EN" - 17 -...
Alféa Extensa Duo A.I. Heat Pump Installation of the outdoor unit 2.2.1 Installation precautions " The outdoor unit must only be installed • The outdoor unit is able to withstand bad weather but outside. If a shelter is required, it must have avoid installing it in a position where it is likely to be broad openings on all 4 sides and installation exposed to significant dirt or flowing water (e.g.
Page 19
Alféa Extensa Duo A.I. Heat Pump • Make sure that the unit does not disturb the surrounding area or inhabitants (noise level, draught, low temperature of the ejected air freezing the plants in its path). • The surface on which the appliance is installed must: - Be permeable (soil, gravel, etc.).
Alféa Extensa Duo A.I. Heat Pump Installation of the hydraulic unit 2.3.1 Installation precautions • Choose the location of the appliance after discussion with the client. • The installation space should comply with current regulations. • To facilitate maintenance and to allow access to the various components, we recommend that you provide sufficient space all around the hydraulic unit (figure...
Alféa Extensa Duo A.I. Heat Pump 3 Refrigeration connections and filling the installation with gas " This appliance uses refrigerant R410A. • Other remarks Comply with the legislation on handling of refrigerants. - After each maintenance operation on the refrigeration circuit and before final connection, take care to put Rules and precautions the caps back in position to avoid any pollution of the...
Page 22
Alféa Extensa Duo A.I. Heat Pump 3.2.2 Creating the flarings - Cut the pipe to an appropriate length with a pipe-cutter without damaging it. - Carefully deburr it, holding the pipe pointing downward flare Flaring tool to avoid introducing filings into the pipe. - Remove the flared connection nut situated on the valve to be connected and slide the pipe into the nut.
Alféa Extensa Duo A.I. Heat Pump Checks and connection " The refrigeration circuit is very sensitive to dust and humidity: check that the area around the connection is clean and dry connection before removing the plugs protecting the Nitrogen refrigeration connectors. "...
Alféa Extensa Duo A.I. Heat Pump Filling the installation with gas " This operation is reserved for installers familiar with the legislation for handling refrigerants. " Creating a vacuum with a calibrated vacuum pump is essential (see APPENDIX 1). " Never use equipment used previously with any refrigerant other than a HFC. "...
Page 25
Alféa Extensa Duo A.I. Heat Pump 3.4.1 Seal test 3.4.2 Creating a vacuum - Remove the protective plug (B) from the filling hole (Schrader) in the gas valve (large diameter). The triple evacuation method (APPENDIX 2) is strongly recommended for any installation and - Connect the high pressure hose from the Manifold to especially when the outdoor temperature is the filling hole (figure 22).
Page 26
Alféa Extensa Duo A.I. Heat Pump 3.4.3 Filling with gas If additional filling is required, do it before filling the hydraulic unit with gas. Refer to paragraph "Additional filling", page - Remove the access plugs (A) from the valve controls. - First of all fully open the liquid valve (small) and then the gas valve (large) using an Allen (hex) key (anti-clockwise direction) without using excessive...
Page 27
Alféa Extensa Duo A.I. Heat Pump 3.4.5 Additional filling The amount needed to fill the outdoor units corresponds to the maximum distances between the outdoor unit and the hydraulic unit as defined here page 22. If the distances are greater, an additional amount of R410A is required. For each type of appliance, this additional amount depends on the distance between the outdoor unit and the hydraulic unit.
Page 28
Alféa Extensa Duo A.I. Heat Pump 3.4.6 Recovering the refrigerant in the outdoor unit " Before performing any maintenance, make sure that all power supplies have been cut off. Stored energy: after cutting off the power " supplies, wait for 1 minute before accessing the internal parts of the equipment.
Page 29
Alféa Extensa Duo A.I. Heat Pump Installation and Operating Manual "1873- EN" - 29 -...
Alféa Extensa Duo A.I. Heat Pump 4 Hydraulic connections Connecting the hydraulic unit to the heating circuit 4.1.1 Flushing the installation Before connecting the hydraulic unit to the installation, rinse out the heating system correctly to eliminate any particles that may affect the appliance's correct operation.
Page 31
Alféa Extensa Duo A.I. Heat Pump 4.1.3 Volume of the heating system You must maintain the minimum installation water volume. Install a buffer tank on the return from the heating circuit in case the volume is lower than this value. Where the system is fitted with one or more thermostatic valves, you must ensure that this minimum water volume is able to circulate.
Alféa Extensa Duo A.I. Heat Pump Connecting to the DHW circuit Attach dielectric connections and DHW pipes to the tank (see figure 26). Insulate the pipes with the insulation provided. " Be sure to place the DHW sensor back in the bottom of the tank thermowell.
Alféa Extensa Duo A.I. Heat Pump Filling and bleeding the installation Check the pipe fixings, tightness of the connectors and the stability of the hydraulic unit. Check the direction in which the water is circulating and that all the valves are open. Proceed to fill the installation.
Alféa Extensa Duo A.I. Heat Pump Heating circulation pump speed settings 1 mbar = 10 mmCE = 100 Pa Variable pressure The circulation pump varies the water pressure depending on the flow rate. Recommended for an installation fitted with radiators (particularly any system with thermostatic valves or zone solenoids).
Page 35
Alféa Extensa Duo A.I. Heat Pump Circulation pump fouled or stuck: If the motor becomes stuck, a start-up cycle is launched. Pression variable Variable pressure If the motor remains stuck, it will be permanently stopped. " Cut off the power supply to the circulation pump Dégazage Gas venting for 30 secs in order to free it and allow a new...
Alféa Extensa Duo A.I. Heat Pump 5 Electrical connections " Before any maintenance operation, ensure that the general power supply is switched off. " Electrical installation must be performed in accordance with current regulations. The electrical diagram for the hydraulic unit is shown on figure 48, page Room sensor A78 (battery/option) Outside sensor...
Alféa Extensa Duo A.I. Heat Pump Cable dimensions and protection rating These cable dimensions are provided for information purposes only and do not exempt the installer from checking that these dimensions match requirements and comply with current standards. • Outdoor Unit Power Supply Heat Pump (HP) Electricity supply 230 V - 50 Hz Max.
Alféa Extensa Duo A.I. Heat Pump Electrical connections on the outdoor unit side " Alféa Extensa Duo A.I. 5, 6 and 8 Access to connection terminals: • Alféa Extensa Duo A.I. models 5, 6 and 8 Cable clamp Serre-Câble - Remove the cowl. •...
Alféa Extensa Duo A.I. Heat Pump Electrical connections on the hydraulic unit side Access to connection terminals: • Contract with Energy Supplier - Remove the front plate. The heat pump can be set to operate within particular types of energy contract, e.g. off-peak, day/night. - Open the power control box.
Alféa Extensa Duo A.I. Heat Pump Outside sensor Room sensor (option) The outside sensor is required for correct operation of The room sensor is optional. the heat pump. Please see the fitting instructions on the sensor’s Please see the fitting instructions on the sensor’s packaging.
Page 41
Alféa Extensa Duo A.I. Heat Pump Power limitation or (Energy Demand Reduction) Tariffs, peak times/off- peak times, day/night External fault External component contact* (faults, power limiter, electricity meter) Outside sensor ** Typass ATL ** Room sensor A59 (if cabled) ** Room sensor A75 ** If the control device does not provide a potential-free contact, the contact must be relayed to create an equivalent wiring.
Alféa Extensa Duo A.I. Heat Pump 6 Commissioning - Close the installation's main circuit breaker. - Press the heat pump's Start/Stop button. Upon initial start-up (or in winter), to preheat the To ensure that inputs EX1, EX2 and EX3 operate compressor, engage the installation's main circuit correctly: Check that the electricity supply's breaker (outdoor unit power supply) several...
Page 43
Alféa Extensa Duo A.I. Heat Pump Easy Start 2nd circuit kit - If the installation covers 2 zones, set "2nd circuit kit" to "Yes". Easy Start Emitters type Area 1 (Direct circuit) - Choose the radiator type for each zone: Low temp.
Alféa Extensa Duo A.I. Heat Pump 7 Controller Interface User Interface 7 September 2017 7 September 2017 15:23 15:23 12° 12° 21,5 21.5 19.5 19,0° 19,0° 19,0° Zone 1 Zone 2 MENU MENU " 1 heating Circuit version " 2 heating circuit version + domestic hot water (DHW) + domestic hot water (DHW) N°...
Alféa Extensa Duo A.I. Heat Pump Display Description 15:23 7 September 2017 12° 21.5 19.5 19,0° 19,0° Zone 1 Zone 2 N° Symbols Definitions N° Symbols Definitions Mode 15:23 Time Comfort Date 7 September 2017 Manual (exemption) Temperature measured by the room 21.5 sensor* 19,0°...
Alféa Extensa Duo A.I. Heat Pump Installer Menu To access the Installer Menu, press and hold the MENU button and turn the knob a quarter turn to the right. To return to the User Menu, repeat the same operation. MENU figure 40 - Installer Menu Navigating the Menus To ...
Alféa Extensa Duo A.I. Heat Pump Modifying Settings • Turn the knob to highlight the setting you wish to change. MENU • Press the knob to accept the change. • Turn the knob to adjust the setting. Installed options • Press the knob to accept your choice. Hydraulic configuration HP configuration System status...
Alféa Extensa Duo A.I. Heat Pump Temperature control The heat pump's operation is subject to the temperature control. The heating circuit water temperature setpoint is adjusted according to the outdoor temperature. If there are thermostatic valves on the installation, these must be fully open or set higher than the normal temperature setpoint.
Page 49
Alféa Extensa Duo A.I. Heat Pump Pente de la 2.75 Heating curve gradient courbe de chauffe ° C 2.25 Standard radiator Radiateur classique 1.75 Radiateur BT Low temperature radiator 1.25 (basse température) Application relève de chaudière With boiler connection Heat pump application only Application PAC seule Dynamic radiators Radiateur dynamique...
Alféa Extensa Duo A.I. Heat Pump 8 Controller Menu Menu Structure Installed options page 51 Hydraulic configuration Heating Control / Temperature control Temperature control page 51 Comfort optimisation ECO mode limitation Setting setpoint T° Time programming General Configuration Time programming Setting setpoint T°...
Alféa Extensa Duo A.I. Heat Pump Installed options Installed options Installed options are configured during commissioning (see page 42). However, you can modify them by accessing the "Installed Options" menu. Name of Appliance - Choose the appliance's power. Installed options Electrical backup Name of Appliance -- KW...
Page 52
Alféa Extensa Duo A.I. Heat Pump Hydraulic configuration Area 1 Control / Temperature control Temperature control " Choose the temperature control to adjust: "Heating". " Two methods for adjusting the temperature control are available: flow temperature or gradient control. ● Control using flow temperature - Set "Room T°...
Page 53
Alféa Extensa Duo A.I. Heat Pump Hydraulic configuration Area 1 Control / Temperature control Comfort optimisation Area 1 Comfort optimisation "Accelerated decrease": ON / Stop. Accelerated decrease Stop "ECO / Comfort switchover" Anticipates time needed to reach the comfort setpoint. Max anticipation "Comfort / ECO switchover"...
Page 54
Alféa Extensa Duo A.I. Heat Pump Hydraulic configuration Area 1 Time programming - Choose "Heating" or "Cooling" as well as the appropriate zone by accessing the menu: "Programming" > "Heating" / "Cooling" > "Area 1" / "Area 2". - Select the day. - Adjust the Comfort period start and end times.
Page 55
Alféa Extensa Duo A.I. Heat Pump Hydraulic configuration Hot water 8.3.2 Hot Water (HW) General Configuration DHW Circuit Configuration Comfort T° charge DHW program + off-peak hours "Comfort T° charge": DHW program + off-peak hours / Off-peak hours / Permanent. Electrical back-up power: 0 to 20 KW.
Alféa Extensa Duo A.I. Heat Pump HP configuration Heat Pump Configuration 8.4.1 Heat Pump Compressor configuration "Minimum shutdown time": 0 mins... 120 mins. Compressor configuration "Max HP T°": 8°C... 100°C. "Post-circulation": 10 secs... 600 secs. Minimum shutdown time 8 mins "Power shedding operating": Automatic, When needed.
Page 57
Alféa Extensa Duo A.I. Heat Pump HP configuration Tariff input configuration Heat Pump Tariff input configuration Power shedding + Type of use "Type of use": Power shedding + Off-peak hours / Smartgrid. Off-peak hours "EX1: function activation": 230V / 0V. EX1: function activation "EX2: function activation": 230V / 0V.
Alféa Extensa Duo A.I. Heat Pump System status System status Active functions Active functions Indoor comfort Heating The "Active Functions" page tells you which services are operating and allows you to change their status. Area 1 Start Area 2 Start - "Indoor comfort": Heating / Cooling / Stop.
Page 59
Alféa Extensa Duo A.I. Heat Pump System status Temperature control "7.6 Temperature control", page Energy consumption Consumption can be displayed per usage: Daily cons. - Heating (Zones 1 and 2). Heating - Cooling. 20kW.h - Domestic Hot Water (DHW). - Total (Heating + Cooling + Hot Water). This information is available for: - the last 8 days: daily consumption (Tdy = Today, D-1 = yesterday, etc.).
Alféa Extensa Duo A.I. Heat Pump Settings Settings Date and time Settings Date and time Monday September 2016 To set the appliance's date and time, access the menu: "Settings" > "Date and Time". 09: 45 Modify Validate Language Settings Language To set the appliance's language, access the menu: English "Settings"...
Page 63
Alféa Extensa Duo A.I. Heat Pump Settings Advanced/simplified menu Two display modes for menus and appliance functions are available: - Advanced menu: - The appliance follows the time programming defined in paragraph "Time programming", page 54. - Simplified menu*: - The appliance operates at a constant temperature set directly by the user. - Some functions are no longer accessible.
Page 64
Alféa Extensa Duo A.I. Heat Pump Settings Areas name Settings Circuits name You can customise the zone names from the menu: Rename Zone 1 in "Settings" > "Areas name". Available names: "Area 1" / "Area 2" / "Day area" / "Night area" / "1st floor" / "Lounge" Rename Zone 2 in / "G.
Page 65
Alféa Extensa Duo A.I. Heat Pump Settings Software versions Software version HMI: xxxx xxxx xxxx xxxx Show the display and controller software versions. Controller: RVS21 - 85.002.030 Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options). Installation and Operating Manual "1873- EN"...
Alféa Extensa Duo A.I. Heat Pump Easy Start Easy Start Easy Start - Turn the knob to choose the language. English - Press the knob to accept. Easy Start Monday September 2016 - Turn the knob to adjust the date. Press the knob to accept. - Repeat this operation for the month, year, hours and minutes.
Page 67
Alféa Extensa Duo A.I. Heat Pump Easy Start Emitters type Area 1 (Direct circuit) - Choose the radiator type for each zone: Low temp. radiator Low temp. radiator / Heat. floor system / Dynamic Radiators / Radiators. Easy Start Cooling - If the installation is fitted with cooling function, choose the zone(s): None / Area 1 / Area 2 / Area 1 and 2.
Alféa Extensa Duo A.I. Heat Pump Temperature sensor. Electronic expansion CN72 valve Pressure sensor CN90 Control board Temperature sensor. Compressor CN64 Temperature sensor. Outdoor CN42 CN40 CN200 CN400 CN62 1 2 3 4 1 2 3 4 Temperature sensor. Evaporator CN65 Temperature sensor.
Page 73
Alféa Extensa Duo A.I. Heat Pump Connections on the heat pump controller, accessories and options (see figure 38, page Connection to terminal blocks and power relay (see figure 37, page figure 48 - Electrical wiring of hydraulic unit (excluding connections made by installer) Installation and Operating Manual "1873- EN"...
Alféa Extensa Duo A.I. Heat Pump 11 Fault Diagnosis 15:23 7 September 2017 12° --,- If a fault occurs, the error number appears on the welcome screen. 24,0° To obtain the error's designation, select it using the knob. Error XXX Error "...
Alféa Extensa Duo A.I. Heat Pump 12 Maintenance of the installation " Before any maintenance operation, make sure that the general power supply is switched off. 12.1 Checking the hydraulic circuit " If frequent refills are required it is absolutely essential that you check for any leaks.
Alféa Extensa Duo A.I. Heat Pump 13 Other maintenance 13.1 Emptying the hydraulic unit Return from - Remove the front panel of the hydraulic unit. the heating circuit - Place the distribution valve in the middle position. Valve motor - Open the drain valve (ref. 5x). Valve - Check that the hydraulic unit's bleeder valve are opened (ref.
Alféa Extensa Duo A.I. Heat Pump 14 Start-up procedure Before switching on the hydraulic unit: • Check the electric wiring. • Check the refrigeration circuit and make sure that it has been gassed. • Check the hydraulic circuit's pressure (1 to 2 bar), check that the heat pump has been bled, along with the rest of the installation.
Page 79
Alféa Extensa Duo A.I. Heat Pump 14.1.2 Starting-up • Start-up (see chapter "Controller Interface", page 44). Not compliant Close the installation's main circuit breaker (outdoor unit power supply) 2 hours before testing => Preheating of the compressor. Press the On/Off Switch => Initialisation takes several seconds. Operation of the heating circulation pump.
Alféa Extensa Duo A.I. Heat Pump 14.2 Commissioning technical datasheet Site Installer Serial N Serial N Outdoor unit Hydraulic unit Model Model Refrigerant type Refrigerant load Checks Operating voltage & current on outdoor unit Compliance with positioning distances Condensate evacuation correct Electric connections / connections tightness No GAS leaks (unit ID N Installation refrigeration connection correct (length...
Page 81
Alféa Extensa Duo A.I. Heat Pump Installation and Operating Manual "1873- EN" - 81 -...
- The Energy Labelling Directive requires an energy performance label for products, in order to encourage customers to buy products that consume less energy. 15.2 ErP specification Trademark / Product name: Atlantic / Alféa ... Extensa Duo Extensa Duo Extensa Duo Extensa Duo A.I.
Page 83
Alféa Extensa Duo A.I. Heat Pump Trademark / Product name: Atlantic / Alféa ... Extensa Duo Extensa Duo Extensa Duo Extensa Duo A.I. 5 A.I. 6 A.I. 8 A.I. 10 Export code 526226 526227 526228 526229 Heating applications 35°C 55°C 35°C...
Alféa Extensa Duo A.I. Heat Pump 16 Instructions for the end user " End-of-life of the appliance Explain to the user the operation of the installation (heating and hot water temperature settings), especially The appliances must be dismantled and recycled by a the ambient sensor functions and the programs that are specialised service.
Page 86
Alféa Extensa Duo A.I. Heat Pump - 86 - Installation and Operating Manual "1873- EN"...
Page 87
Alféa Extensa Duo A.I. Heat Pump Installation and Operating Manual "1873- EN" - 87 -...
Page 88
Please contact your heating engineer or After Sales service for further information. * Depending on the national regulations of each member state. Commissioning date: atlantic-comfort.com Société Industrielle de Chauffage SATC - BP 64 - 59660 MERVILLE - FRANCE Contact details of your heating engineer or After Sales service.
Need help?
Do you have a question about the WOYA 060 LFCA and is the answer not in the manual?
Questions and answers