RAMBO HP200LPB Installation & Operating Instructions Manual

High pressure burner

Advertisement

Quick Links

INSTALLATION & OPERATING INSTRUCTIONS
MODEL: HP200LPB
MODEL: RH31LT
IMPORTANT:
Carefully read and understand this Installation & Operating Instruction booklet in full
Familiarise yourself with the appliance BEFORE connecting the appliance to the gas cylinder
Retain this manual for future reference
You MUST purchase a suitable regulator and hose assembly
The appliance should be installed in accordance with the following:
AS/NZS 5601.1: gas installations part 1: general installations
Manufacturer's installation instructions;
Local gas fitting regulations;
Municipal building codes; and
Any other relevant statutory regulation.
The appliance must be installed, serviced and removed by an authorised person only.
REGULATOR AND HOSE ASSEMBLY DETAILS
This appliance must be connected to a certified hose and regulator assembly to ensure safe operation as
follows: Propane Gas regulator fitted with a POL type inlet fitting, outlet pressure of 100 kPa and Certified to
AS4621 and an 8mm High Pressure hose (maximum length 1.8 metres) certified to AS/NZS 1869 class 'C' or
'D'. The hose outlet fitting required to ensure compatibly with the inlet connection of this appliances is ¼" BSP
female threaded nut and 60º inverted flare.
THE CORRECT ASSEMBLY MUST BE USED - DO NOT USE ADAPTORS
The use of any equivalent certified hose/regulator assembly compliant with the requirements above is
FOR OUTDOOR USE ONLY
Rambo
HIGH PRESSURE BURNER
®
MODEL: HP200LPWF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HP200LPB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RAMBO HP200LPB

  • Page 1 Rambo ® HIGH PRESSURE BURNER INSTALLATION & OPERATING INSTRUCTIONS MODEL: HP200LPB MODEL: HP200LPWF MODEL: RH31LT IMPORTANT: • Carefully read and understand this Installation & Operating Instruction booklet in full • Familiarise yourself with the appliance BEFORE connecting the appliance to the gas cylinder •...
  • Page 2: Package Content

    / large for the burner size, as they could be unstable on the trivet. • The maximum vessel size is Ø50 cm for HP200LPWF model, Ø70 cm for HP200LPB model and Ø60 cm for RH31LT model.
  • Page 3 Do not operate any electrical equipment in the vicinity of a gas leak; Contact your licensed gas fitter to repair the leak and re-light the appliance. NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF. IT MUST BE SERVICED AND REPAIRED BY A LICENSED PLUMBER OR GAS FITTER HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 4: Component & Parts

    Burner Cap Burner Head Bowl Regulator Hose RH31LT Part Name Gas Manifold Pilot Tube Bowl Outer Ring Cap Inner Ring Cap Burner Head HP200LPB Part Name Trivet HP200LP Burner Head Regulator Adjustable Foot Body Frame HP200LPWF HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 5 Some examples of shelter are shown below, IMPORTANT: The dimension and building materials of the shelter must be meet the requirements mentioned above, or contact your gas filter / local Gas Authority for information on clearances and material required HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 6 (2) 30% or more in total of the remaining wall side, back and front wall areas is open and unrestricted (examples 4 & 5). (3) In the case of balconies, 20% or more of the total wall area shall remain open and unrestricted. EXAMPLE 1 EXAMPLE 2 HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 7 EXAMPLE 3 EXAMPLE 4 EXAMPLE 5 HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 8 100kPa. Use the regulator with the right threads. DO NOT use adaptors. The use of any equivalent certified hose/regulator assembly compliant with the above requirements is acceptable. WARNING! IT MAY HAZARDOUS TO USE WRONG TYPE OF REGULATOR. HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 9 *Only use model LF103P-100KPA regulator on model RH31LT, and model LF103P-61KPA regulator on models HP200LPWF & HP200LPB. Contact Austcrown or dealer for replacement. WARNING: YOU MUST NEVER USE A NAKED FLAME TO TEST FOR GAS LEAKS.
  • Page 10: Operating The Burner

    After use, turn the gas cylinder valve off, wait for the flame to go out, then turn the appliance control valves off. Rotate the Flame Control Valve and Pilot Control Valve clockwise until they are tight. HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 11 Clean the bowl after each use. Always wipe off spills, do not leave spills to dry on the surface of the bowl or burner. Ensure burner cap/s are place back on the burner head correctly HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 12 This cooker is suitable for use with propane gas only and MUST NOT be converted for use on any other type of gas for further advice, contact place of purchase or their authorised agent for advice. WARNING: IT MAY HAZARDOUS TO ATTEMPT TO FIT OTHER TYPES OF GAS CONTIANERS HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 13: Troubleshooting

    (Incomplete Combustion ) Flame holes of the Clean the burner head and the burner cap. burner are clogged. Nozzle is clogged. Contact your dealer for a service/repair. DO NOT ATTEMPT TO REPAIR IT YOURSELF. HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...
  • Page 14: Specifications

    Pilot: Ø0.30mm Pilot: Ø0.30mm Gas Type Propane gas Ignition Manual with pilot System Gas Pressure 100 kPa - RH31LT, 61 kPa - HP200LPB & HP200LPWF Gas Inlet ¼” BSPM 60° coned Fitting Weight: 7.72 kg 16.30 kg 33.0 kg Country of...
  • Page 15 HP200LPB, HP200LPWF, RH31LT OPERATING INSTRUCTIONS...

This manual is also suitable for:

Rh31ltHp200lpwf