©Termo-tehnika, d.o.o.
7.2
Technical data
7.2.1 External device
Device
Corresponding hydro module
Mark
Version
Heat source
Heat sink
Controller
Device placement
Placement of the controller un.
Compressor
Defrosting
Circulation pump, secondary
Capacity
Heating
A2/W30-35
A7/W30-35
A-7/W35
Cooling
A35/W12-7
Electrical data
External and internal unit
9)
Max. electrical power
External unit
Rated voltage
Max. operational current
Max. electrical power
12)
Fuses
Electrical power cable
4)
Refrigerant system
Refrigerant - type
Refrigerant - quantity
Max. operational pressure
Cooling (freon) line
Gas
Liquid
Primary side (heat source) - air
Nominal flow
Heating
Range of operation -
min. / max. air temperature
Cooling
Range of operation -
min. / max. air temperature
ID.: 17-16-24-3006-03 | 12.2016
WPLV-09-S1 NT
Active (change of the cooling circuit direction)
Heating power / electrical power / COP
kW / kW /
5,3 / 1,4 / 3,7
-
kW / kW /
5,4 / 1,2 / 4,4
-
kW / kW /
5,6 / 2,0 / 2,8
-
Cooling power / electrical power / EER
kW / kW /
6,1 / 2,3/ 2,6
-
kW
9,8
~ 230 V; 50 Hz
A
kW
3.2
A
1 x 20
mm2
3 x 2,5
kg
1,9
MPa
mm
mm
9,52 (3/8'')
3
m
/h
3,600
° C
° C
WPLV-14-S1 NT
HM-141 S1, HM-142 S1
External air
Water
TERMOTRONIC 3000 WEB
External
Internal
1 x twin Rotary
/
10,6 / 2,1 / 5,1
10,9 / 3,7 / 3,0
3N~ 400 V; 50 Hz
19
R410A
5,0
15,88 (5/8'')
-20 / 40
20 / 40
2)
9,6 / 2,5 / 3,9
3)
12,1 /4,8 / 2,5
14,2
11
7,6
3 x 16
5 x 2,5
2,98
9,52 (3/8'')
7,200
35
Need help?
Do you have a question about the WPLV-09-S1 NT and is the answer not in the manual?