YOKOGAWA GM10 User Manual

YOKOGAWA GM10 User Manual

Smartdac+ data acquisition system gm first step guide
Hide thumbs Also See for GM10:

Advertisement

User's
Manual
Contents
Introduction ................................................................................. 2
Checking the Package Contents ................................................. 3
MODEL and SUFFIX Codes ....................................................... 4
Standard Accessories ................................................................. 5
Module Notation .......................................................................... 6
GM Overview ............................................................................. 6
GM Configuration ........................................................................ 6
Module Version and Notes on Linking .......................................... 6
Channel Names .......................................................................... 7
Operating Procedure ........................................................8
Basic Operation ..............................................................10
Names of the GM10 Parts ..........................................................10
Configuring the GM via USB Communication .............................12
Starting to Measure and Record .................................................12
Installation.......................................................................13
Installation Location ....................................................................13
Installation Procedure .................................................................13
Unit External Dimensions (Unit: mm) ...........................................13
Installing on a Desktop or Floor.................................................. 14
Mounting on a DIN Rail .............................................................. 14
Mounting on a Wall .................................................................... 14
Wiring ..............................................................................15
Precautions to Be Taken While Wiring ........................................16
Removing and Attaching a Terminal Cover .................................16
Removing and Attaching a Terminal Block ..................................16
Wiring Procedure .......................................................................17
Wiring the Clamp Terminal ..........................................................17
Wiring to a GX90XA Analog Input Module ..................................17
Wiring to a GX90XD Digital Input Module....................................19
Wiring to a GX90YD Digital Output Module .................................19
Wiring to a GX90WD Digital I/O Module .................................... 20
Data Acquisition System GM
First Step Guide
Wiring to a GX90XP Pulse Input Module.................................... 20
Wiring to a GX90YA Analog Output Module ............................... 20
Wiring to a GX90UT PID Control Module ................................... 20
(/C3 option) ............................................................................21
Connecting to the USB Port .......................................................21
Connecting to the Ethernet Port .................................................21
Wiring the Power Supply ........................................................... 22
Turning the Power On and Off ................................................... 23
Connecting GX90EX Expansion Modules ................................. 23
Bluetooth Connection Procedure (/C8 option) ............................ 24
IM 04L55B01-02EN
4th Edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM10 and is the answer not in the manual?

Questions and answers

Summary of Contents for YOKOGAWA GM10

  • Page 1: Table Of Contents

    Connecting GX90EX Expansion Modules ......... 23 Operating Procedure ............8 Bluetooth Connection Procedure (/C8 option) ......24 Basic Operation ..............10 Names of the GM10 Parts ............10 Configuring the GM via Ethernet Communication .......10 Configuring the GM via USB Communication ......12 Starting to Measure and Record ..........12 Installation...............13...
  • Page 2: Introduction

    Expansion Module use of the product. User Registration • When SMARTDAC+ GM contains GM10 with the optinal code of /C8, SMARTDAC+ GM is built in compliance with Thank you for purchasing YOKOGAWA products. We invite you to register your products in order to receive the most up requirements of R&TTE Derective:...
  • Page 3: Checking The Package Contents

    • SD cards are delicate and should be handled with caution. nameplate on the GM. • Yokogawa provides no warranty for damage to, or loss of data recorded on the SD card, regardless of the cause of No. (Instrument number) such damage or loss.
  • Page 4: Model And Suffix Codes

    GX90EX MODEL and SUFFIX Codes Model Suffix Code Description GM10 GX90EX I/O Expansion Module Optional Ports 2 ports Model Suffix Code Description Code Type -TP1 Twisted pair cable Data Acquisition Module for SMARTDAC+ Always N GM10 Area -N General Standard (max. no. of measurement ch:...
  • Page 5: Standard Accessories

    Clamp terminal 438921 100Ω±0.1% (for clamp terminal) Area N General 438922 10Ω±0.1% When the GM10 has the /MT option, GX90XP can receive pulse integration. GM10 Style Number, Release Number, and GX90YA Firmware Version Number Model Suffix Code Description Style number: The GM hardware ID number.
  • Page 6: Module Notation

    The GM configures a system with a combination of various limits. modules. ・ When GX90XA-10-T1 is included The unit that includes the GM10 is called the main unit. A unit Single unit system connected to the main unit via a GX90EX expansion module Multi unit system: main unit No limi is called a sub unit.
  • Page 7: Channel Names

    ・ Up to 10 modules consisting of GX90YD, GX90WD, and Channel name GX90UT can be connected to the system. ・ One GX90WD module can be connected to each unit. ・ Two GX90YA modules can be connected to the main unit and to the sub unit. Unit number Main unit: 0 ・ Up to 10 GX90YA modules can be connected to a GM10-1 Sub unit: 1 to 6 system and up to 12 to a GM10-2 system. ・ If the measurement mode is High speed, a GX90XD or Slot number GX90WD module can be connected to the system. ・ If the measurement mode is High speed, only GX90XA- Main Unit (single unit system)
  • Page 8: Operating Procedure

    Configure the GM settings. are possible using a Web application. “Basic Operations” A PC with Internet Explorer installed is required. Set the GM10 IP address. If you need to set the time Set the measurement mode zone or DST (Daylight Saving Reconfigure.
  • Page 9 IP Address Configurator Screen Example • Search for GM10s in the same network segment and list them. • GM settings can be configured offline from a Web browser. • Set the IP address and other parameters of the GM10. IM 04L55B01-02EN...
  • Page 10: Basic Operation

    High speed A mode in which the shortest measurement interval is 1 ms Open the SD card slot cover on the GM10 front panel, and Dual interval A mode in which measurement is possible by insert an SD card (see the names of the parts).
  • Page 11 2. In the Address box, enter “http://” followed by the GM10 IP Setting Measurement and Recording Conditions address. The Web application starts. The example here explains how to change the recording Calib tab Reconfiguration interval when the following settings are at their default values.
  • Page 12: Configuring The Gm Via Usb Communication

    2. When a Recording dialog box appears, click Start Manual (IM 04L61B01-02EN). recording. Recording will start. 1. Connect a cable to the GM10 USB port (mini B type) to • To stop recording, in step 2 above, click Stop recording. communicate with the PC. Connect using the following From Hardware Configurator communication conditions.
  • Page 13: Installation

    • Ambient temperature range between -20 to 60°C (but -20 to 50°C when any of the following.) Main Unit (multi unit system) When using GM10 (Optional, / C8) and GX90YD, GX90WD, GX90XA-T1 (electromagnetic relay type), GX90YA, GX90UT. • Ambient humidity between 20 to 85%RH No condensation should be present.
  • Page 14: Installing On A Desktop Or Floor

    Vertical Dimensions for DIN Rail Mounting Installing on a Desktop or Floor DIN rail The system can be placed upright because the GM90PS and Unit: mm GM90MB have legs. For the module installation procedure, see “Operating Procedure.” 68.6 Legs Mounting on a DIN Rail Mounting on a Wall Wall Mount Dimensions When mounting on a DIN rail, place screws at 70 mm...
  • Page 15: Wiring

    Wiring In wall mounting, the GM90PS is the reference. First, as shown in the figure below, fix the GM90PS securely in place with two screws. Next, link GM90MBs to the GM90PS. Screw ● To prevent electric shock while wiring, make sure that the power supply is turned off. ● If a voltage of more than 30 VAC or 60 VDC is to be ap- plied to the output terminals, use ring-tongue crimp-on lugs with insulation sleeves on all terminals to prevent...
  • Page 16: Precautions To Be Taken While Wiring

    Removing and Attaching a Terminal Cover Precautions to Be Taken While Wiring Removing the Terminal Cover Take the following precautions when wiring the input signal cables. Loosen the screw at the bottom section of the terminal ● With a screw terminal, we recommend that you use a cover, and remove the cover.
  • Page 17: Wiring Procedure

    Wiring Procedure Wiring to a GX90XA Analog Input Module A terminal cover is screwed in place on the I/O terminal block. Universal / Low withstand voltage relay / A label indicating the terminal arrangement is affixed to the Electromagnetic relay / Current (mA) type cover.
  • Page 18 Clamp terminal Terminal Arrangement M3 screw terminal Term. Symbol CH Term. Symbol Term. Term. Term. Symbol Symbol Symbol Clamp terminal CH10 Term. Term. Symbol 1 There are no symbol indications for the electromagnetic relay type, current input type, or low withstand voltage relay type.
  • Page 19: Wiring To A Gx90Xd Digital Input Module

    Terminal Arrangement Terminal Arrangement M3 screw terminal Term. No. Symbol Term. No. Symbol Term. Term. Term. Symbol Symbol Symbol DI10 DI11 DI12 Not not DI13 DI14 DI15 DI16 Not not Not not Internal circuit Note: Do not apply voltage outside the allowable input voltage Not not Not not...
  • Page 20: Wiring To A Gx90Wd Digital I/O Module

    Wiring to a GX90WD Digital I/O Module Internal circuit Note: Do not apply voltage outside Terminal Diagram 5 V DC the allowable input voltage range across input terminals. Approx. 5kΩ Terminal Diagram Doing so may damage the GM. Internal circuit Note: Input type: Photocoupler isolation Do not apply...
  • Page 21: Connecting To The Rs-422/485 Connector (/C3 Option)

    Symbol Connecting to the Ethernet Port DI-COM Checking the Connection and Communication Status DO-COM You can use the indicators that are located above the GM10 AI1(/A) AI1(-/b) AI1 (+/B) Ethernet port to check the connection status of the Ethernet AI2(/A)
  • Page 22: Wiring The Power Supply

    ● Connect the power cord after checking that the power switch of the GM90PS is turned OFF. ● To prevent electric shock and fire, be sure to use a power cord purchased from Yokogawa Electric Corpo- ration. ● To prevent electric shock, ensure that the power sup- ● Make sure to connect protective earth grounding to ply is turned off. prevent electric shock. Insert the power cord into a ● To prevent fire, use 600 V PVC insulated wires (AWG20...
  • Page 23: Turning The Power On And Off

    3. Make that the source voltage is within the maximum rated ● The GM10 is not accessing the external storage me- voltage range of the provided power cord. Then, connect dium. the other end of the cord to the outlet. Use a grounded three-prong outlet. You can turn the power on and off using the power switch on the front panel of the GM90PS.
  • Page 24: Bluetooth Connection Procedure (/C8 Option)

    (orange) Dot display 7 segment LED 2. Hold down the GM10 USER1 key for at least 3 seconds. The 7 segment LED displays the unit number and operation The BT LED (orange) will turn on, and the GM will enter errors.

This manual is also suitable for:

Gm90psGm90mb

Table of Contents

Save PDF