Do you have a question about the TP4-20 and is the answer not in the manual?
Questions and answers
Summary of Contents for Technoalarm TP4-20
Page 1
TP4-20 4 TO 20 ZONES CONTROL PANEL EN 60950 EN 50130-4 EN 50081-1 USER MANUAL Release: Update: March 2007 Language: English FW release:...
Page 2
The features of the control panel can be subject to change without notice. Unauthorized reproduction or distribution of this manual, or any portion of it, on any device and in any form, is prohibited. The contents of this manual may be subject to change without notice. User Manual - TP4-20...
Page 3
The above product is in conformity with the Commission Decision TBR21 which guarantees the PSTN connection features in Europe. In addition, the correct use of the radio spectrum avoiding harmful interferences is guaranteed. Turin, July 10th, 2006 Negro Giovanni TP4-20 - User Manual...
Page 5
PREFACE APPLICATION NOTES The alarm system TP4-20 is very easy to use. Thus, it is recomended to arm the system every time you leave the house or appartment unattended, even if only for a short period of time. For your own safety keep all the access codes secret.
2-11 KEY READER ATPK 2-11 2.5.1 LED 4 - OCG/General control 2-11 2.5.2 LED 1, 2, 3 - Program status 2-12 RESET OF LED SIGNALING 2-12 PROGRAMMING MASTER MENU 3.1.1 Activation/deactivation of the remote controls TP4-20 - User Manual Index...
Page 8
CONSULTATION OF THE EVENT BUFFER 4-13 CONTROL BY KEYPOINT AND WIRELESS KEY CONTROL BY KEY INTERFACE TP PK AND KEY READERS ATPK 5.1.1 Arming 5.1.2 Disarming 5.1.3 Bypass 5.1.4 Special operating conditions CONTROL BY ELECTRONIC KEYPAD TP SDN Index User Manual - TP4-20...
Page 9
CONTROL BY TELEPHONE TELEPHONE MENU 6.1.1 System status check 6.1.2 Arming/disarming of the programs 6.1.3 Activation/deactivation of the remote controls 6.1.4 Remote digital verification (RDV) 6.1.5 Recording of the telephone opening message ALARM CALL SKIP ANSWERING MACHINE TP4-20 - User Manual Index...
1. GENERAL FEATURES TP4-20 is a new generation microprocessor-based control panel, extremely user-friendly. It controls 4 to 20 zones selectable from the inputs of the CPU board, or from the internal input extension module or that conected via serial bus or the optional wireless modules.
Recording of the opening message (with master code only) It is possible to record the opening message with a fix duration of approximately 10 seconds. The opening message is reproduced at the beginning of every alarm call. General Features User Manual - TP4-20...
The common zone (entrance), however, is activated only if the programs of both appartments it is included in are armed simultaneously. COMPOSITION TP4-20 - User Manual General Features...
Page 14
Do not open the control panel casing. Its opening beside causing a tamper alarm and the activation of the sirens gives access to parts of the electronic board with dangerous operating voltages. If need be always consult your installer. General Features User Manual - TP4-20...
The led remains lit until disarming of the program. Led off = program disarmed The events, arming, disarming and bypass, are stored in the event buffer of the control panel with indication of date and time. TP4-20 - User Manual Signaling...
Once the alarm has stopped it becomes lit. Led on = alarm stored (alarm memory) To identify the zone in alarm or the kind of tamper alarm consult the event buffer of the control panel. Signaling User Manual - TP4-20...
9 hours and 50 minutes. The led produces the following signaling: Led blinking = alarm active The led starts blinking upon power failure, even if the alarm release is delayed, and continues blinking until mains restore. TP4-20 - User Manual Signaling...
2.1.10 HOLD-UP ALARM The hold-up alarm does not generate any signaling, neither through led nor on the display of the console. La alarma coacción se graba en la memoria de eventos de la central. Signaling User Manual - TP4-20...
CONTROL PANEL IN STAND-BY Led on = alarm stored (alarm memory) The led becomes lit on disarming of the control panel, and is lit until the program is armed again. Led off = no alarm TP4-20 - User Manual Signaling...
Battery voltage drop below the minimum level guaranteeing correct functioning of a wireless device (2.7V) The led produces the following signaling: Led blinking = alarm active The led starts blinking upon voltage drop below the limit and continues blinking until battery restore. Signaling User Manual - TP4-20...
Led on = alarm stored (alarm memory) False code or false key alarms are stored in the event buffer of the control panel with indication of date en time. TP4-20 - User Manual Signaling...
The led starts blinking upon detection of an alarm on one of the zones included in the program and continues blinking during the entire alarm time. Depending on programming, the indoor and/or outdoor sirens are activated, too. Signaling User Manual - TP4-20...
(if it is armed), and in any case until it is armed again. Both events, low battery and battery restore, are stored in the event buffer with indication of date and time. TP4-20 - User Manual Signaling...
Once the alarm has stopped, the led is switched off. Led on = alarm stored (alarm memory) The led becomes lit on disarming of the control panel, and is lit until the control panel is armed again. Signaling User Manual - TP4-20 2-10...
Supervision alarm of a wireless device (the device fails to carry out the test transmission towards the control panel for more than the time programmed) False key (attempt at arming with unknown key) False code (pressing of 32 keys without entering a valid code) TP4-20 - User Manual Signaling 2-11...
WARNING The active alarms are not stopped on reset of led signaling. Led signaling for tamper and general alarm (e.g. low battery, power failure) cannot be reset by the user. Consult the installer. Signaling User Manual - TP4-20 2-12...
3. PROGRAMMING Programming of the control panel is only possible by PC or LCD console (LCD020 or LCD012). The LED consoles (LED06) and the secondary control units (indicated as keypoints) do not permit programming. MASTER MENU TP4-20 - User Manual Programming...
Page 28
While a console is in use, all the other consoles of the system are disabled and view Waiting. Commands available + wy to select the submenu to enter the submenu selected + CL-EX to confirm programming and quit Programming User Manual - TP4-20...
+ CL-EX to confirm and quit WARNING If a zone is included in more than one program and is defined common zone, it is only activated when all the programs it belongs to are armed. TP4-20 - User Manual Programming...
Every timer can be activated at a determined hour. Commands available + wy to select the parameter to be modified Time + 0...9 to program the hour of activation 12 : 32 [hh:mm] + CL-EX to confirm and quit Programming User Manual - TP4-20...
Call back (numbers and condition of execution of the call back) Mobile (parameters of the telephone communicator with GSM module) Commands available + wy to select the parameter to be programmed to confirm the selection TP4-20 - User Manual Programming...
Page 32
011555666677777 + 0...9 to program the telephone number + #* to program the DTMF symbols # (hash) and * (star) inside the number + MEM to program a pause + CL-EX to confirm and quit Programming User Manual - TP4-20...
Page 33
The SMS must be composed with the help of a mobile phone and sent to the number Waiting corresponding to the SIM card of the GSM telephone communicator. Afterwards, te SMS must be loaded onto the control panel. TP4-20 - User Manual Programming...
On the display is viewed current programming: Function disabled [ # ] Function enabled Commands available + wy to select the function to enable the function to disable the function + CL-EX to confirm and quit Programming User Manual - TP4-20...
Page 35
Disabling remote arming/disarming by telephone (disables the code from arming/ disarming of the programs by telephone) Disabling direct arming/disarming (disables the code from direct arming/ disarming, i.e. simultaneous arming/disarming of all the programs enabled for by pressing # (hash)) TP4-20 - User Manual Programming...
Automatic abort on disarming (enables the key for the automatic block of the alarm call cycles of all the active telephone channels and those waiting on disarming of the system) Programming User Manual - TP4-20 3-10...
Access period associated to the wireless key selected Commands available + wy to select the access period to associate the access period to the wireless key selected to undo the association + CL-EX to confirm and quit TP4-20 - User Manual Programming 3-11...
Page 38
On the display is viewed current programming: Function disabled [ # ] Function enabled Commands available + wy to select the function to enable the function Programming User Manual - TP4-20 3-12...
Wireless modules (exclusion of the wireless receiver selected (1 to 2)) Control panel (exclusion of the control panel) SELECTION OF THE DEVICE + wy Exclusion to select the device/zone to be excluded Zones to confirm the selection TP4-20 - User Manual Programming 3-13...
The sounding or flashing time programmed, however, is not considered during the test that has a fix duration of 60 seconds unless it is interrupted by pressing CL-EX. Programming User Manual - TP4-20 3-14...
3.1.13.2 PROTOCOL Options Permits to select one of the following communication protocols (usually software): Protocol Software (standard communication with the monitoring station) Ethernet (communication with the ethernet interface PROG NET) Protocol Software TP4-20 - User Manual Programming 3-15...
+ 0...9 to program the telephone number + #* to program the DTMF symbols # (hash) and * (star) inside the number + MEM to program a pause + CL-EX to confirm and quit TP4-20 - User Manual Programming 3-17...
Page 45
1 master code (default 12345) The master code is generally reserved to the owner of the system and gives access to the master programming menu as well as the standard functions of arming/disarming and bypass. TP4-20 - User Manual Control by Console...
Page 46
The user who holds the master code can always act on all the programs of the system. 20 standard user codes (default 00000) Every code can be enabled individually for arming/disarming or bypass of determined programs. Control by Console User Manual - TP4-20...
Page 47
OPERATIONS EXECUTABLE WITHOUT CODE TP4-20 - User Manual Control by Console...
On arming of the program in presence of open zones, the alarm devices programmed (sirens/logic outputs/telephone channels) are activated unless the open zones are excluded with a procedure explained lateron. VIEWING OF SYSTEM STATUS LCD020 Program-oriented LCD console Control by Console User Manual - TP4-20...
The programs in question are only armed on its expiry. On expiry of the exit time, the program leds become lit and remain lit until disarming of TP4-20 - User Manual Control by Console...
Page 50
WARNING The programs that are already armed are not influenced. To abort arming of the programs selected press CL-EX (LCD020 and LCD012). The process is aborted and the control panel returns to stand-by. Control by Console User Manual - TP4-20...
If the programs selected do not contain delayed zones, on expiry (or abort) of the zone exclusion time, the programs in question are armed and the corresponding program leds become lit immediately. TP4-20 - User Manual Control by Console...
On the attempt at doing so, on the display is viewed ! ARM. DENIED ! followed by the kind of alarm. Remove the reason of alarm or use a code enabled for the bypass of general alarms. Control by Console User Manual - TP4-20...
For this enter the master code or a standard user code (enabled for the programs armed) reducing the last digit by one unit, e.g. master code (default code 12345): + 12344 The control panel is apparently disarmed, i.e. all the program leds are switched off, TP4-20 - User Manual Control by Console...
Outside the access periods associated the codes are not accepted by the control panel and any attempt at acceding to the system will have no effect. When trying to do so, on the display is viewed ACCESS ! DENIED !. Control by Console User Manual - TP4-20 4-10...
At the time and for the period of time programmed by the installer on the display is Automatic viewed a warning of imminent automatic arming and blink the program leds on the console. According to programming, the buzzers of the consoles are activated, too. TP4-20 - User Manual Control by Console 4-11...
The abort command stops all the active alarm calls cycles as well as those waiting. The abort of the telephone calls is not permitted in case of hold-up alarm. In this case, the cycle continues uninterrupted. Control by Console User Manual - TP4-20 4-12...
Issue of the call on the first number associated to the channel 2 - [issue] Issue of the call on the second number associated to the channel (see table below) ATENCION Los eventos no se pueden cancelar de la memoria de eventos. TP4-20 - User Manual Control by Console 4-13...
Page 58
Answer with confirmation - all events confirmed Answer Answer ok M. answ. ko Answer without confirmation - no event confirmed - GSM M. answ. ok Answer with confirmation - all events confirmed - GSM Control by Console User Manual - TP4-20 4-14...
The interface for electronic keys permits to control merely 3 of the 4 programs through the key readers connected. Program status is signaled by the leds on the key readers. TP4-20 - User Manual Control by Keypoint and Wireless Key...
Page 60
The zones defined as delayed upon arming observe the exit time programmed by the installer. If the program selected contains delayed zones, on expiry of the zone exclusion time follows the exit time and the Control by Keypoint and Wireless Key User Manual - TP4-20...
Remove the key from the key reader. WARNING The electronic key introduced will effect disarming exclusively of the programs it is enabled for. Possible other programs armed are not affected. TP4-20 - User Manual Control by Keypoint and Wireless Key...
If a general alarm is active (yellow OCG LED is blinking), arming of the control panel by key is not permitted unless the key has been enabled for the bypass of the general alarms. Control by Keypoint and Wireless Key User Manual - TP4-20...
Open zones/active zone alarms are not signaled unless you try to arm the control panel. In the arming phase the yellow LED 7 OCG signals zone status: LED blinking = open zones LED off = zones ok TP4-20 - User Manual Control by Keypoint and Wireless Key...
Page 64
When trying to do so, the system ignores the command. The green LED 5 remains lit and the red program LED remain off. After 5 seconds, the electronic keypad returns to stand-by. Control by Keypoint and Wireless Key User Manual - TP4-20...
When trying to do so, the system ignores the command. The green LED 5 remains lit and the red program LED remain off. After 5 seconds, the electronic keypad returns to stand-by. TP4-20 - User Manual Control by Keypoint and Wireless Key...
If a general alarm is active (the corresponding LED is blinking), arming of the control panel is not permitted with code unless the code is enabled for the bypass of the general alarms. Control by Keypoint and Wireless Key User Manual - TP4-20...
On the console the LED corresponding to the programs previously armed by this wireless key are switched off. The buzzer of the console is activated for approx. 2 seconds The programs previously armed by this wireless key, are disarmed. TP4-20 - User Manual Control by Keypoint and Wireless Key...
Arming program becomes activation bypass program Disarming program becomes deactivation bypass program Disarming becomes deactivation general bypass To activate bypass, simply press the corresponding function key. Control by Keypoint and Wireless Key User Manual - TP4-20 5-10...
On answering, the control panel emits a beep. To enter the telephone menu, enter the master code or a standard user code programmed accordingly, e.g. master code (default code 12345): + 12345 The control panel reproduces the following voice messages: TP4-20 - User Manual Control by Telephone...
Exclusion of the open zones contained in program 4 The control panel plays the message relating to the exclusion of open zones. WARNING The zones in trouble cannot be excluded. to return to the main menu Control by Telephone User Manual - TP4-20...
Playing of opening message RECORDING OF THE OPENING MESSAGE The duration is fix. Therefore, it is recommended to record a message of a duration of approximately 10 seconds in order to avoid silent periods during play-back. TP4-20 - User Manual Control by Telephone...
The control panels usually emit 1-second rings staggered with 4-seconds pauses. The standard counting method is always active. From the second ring onwards the skip of the answering machine is deactivated automatically. The function is reactivated after approximately 1 minute. Control by Telephone User Manual - TP4-20...
Need help?
Do you have a question about the TP4-20 and is the answer not in the manual?
Questions and answers