Stop; Switch Off; Timer And Standby - Husqvarna Automower 105 Operator's Manual

Hide thumbs Also See for Automower 105:
Table of Contents

Advertisement

4.4 Stop

1. Press the STOP button.
The robotic lawnmower stops, the blade motor stops
and the hatch opens.

4.5 Switch off

1. Press the STOP button.
2. Set the main switch to position
Always switch the robotic lawnmower off using the main
switch if it requires maintenance or if the robotic
lawnmower must be moved outside the working area.

4.6 Timer and Standby

Use the timer function (see
a downtrodden lawn.
4.6.1 Standby
The robotic lawnmower has an inbuilt standby period
according to the Standby time table. The standby period
provides for instance a good opportunity to water or play
games on the lawn.
Model
Standby time, minimum hours
per day
Automower 105
10
4.6.2 To set the timer
When setting the timer, calculate that the robotic
lawnmower mows about the amount of the number of
square meters per hour and day listed in table Work
capacity.
Model
Approximate work capacity, m
hour and day
Automower 105
43
If the working area is for example 360 m
Automower 105 must operate for 8 hours a day. The
times are approximate and depend for instance on grass
quality, blade sharpness and battery age.
WARNING: Use the timer to avoid mowing
when there are usually children, pets and
136 - 003 -
0 .
Timer on page 21 ) to avoid
2
per
2
in size,
anything else that could be damaged by the
rotating blades on the lawn.
The factory setting for the timer is 07:00 - 23:00 and it
allows mowing every day of the week. However, the
robotic lawnmower will not operate during the built-in
standby period.
4.6.3 Example 1
The times used in this example are applicable to
Automower 105, but the principle is the same for other
models.
Period 1 : 07:00 - 23:00
Timer setting,
Active period (A): 07:00 - 21:00
The factory setting ensures that the robotic lawnmower
begins cutting the lawn at 07:00. However the mower is
parked in standby mode in the charging station from
21:00 and rests until it starts cutting again at 07:00.
If the timer setting is divided into 2 work periods, the
standby period can be divided into a number of periods.
The minimum standby period time must however be
according to the Standby time table.
Automower 105
Operation, A = max. hours
Charging/Standby, B = min. hours
4.6.4 Example 2
The times used in this example are applicable to
Automower 105, but the principle is the same for the
other models.
Period 1 (A): 06:00 - 17:00
Timer setting
Period 2 (C): 20:00 - 23:00
Timer setting
Active period (A): 08:00 - 16:00
Active period (C): 20:00 - 23:00
The robotic lawnmower will operate between 06:00 and
17:00. It will begin again at 20:00 but stops running at
23:00 due to standby mode until it starts again at 06:00.
14
10
Operation - 31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents