BenQ PM060PWX Installation Manual
BenQ PM060PWX Installation Manual

BenQ PM060PWX Installation Manual

Solar photovoltaic modules, poly 60 cells series, mono 60 cells series, mono 60 cells with light weight series, poly 72 cells series, back contact 96 cells series

Advertisement

B
e
n
Q
S
o
l
a
B
e
n
Q
S
o
l
a
I
n
s
t
a
l
l
a
t
i
o
n
I
n
s
t
a
l
l
a
t
i
o
n
(
I
E
C
,
E
T
L
)
(
I
E
C
,
E
T
L
)
Poly 60 cells series
Poly 60 cells
series
Poly 60 cells
Poly 60 cells
series
series
Mono 60 cells series
Mono 60 cells series
Mono 60 cells series
Mono 60 cells series
Mono 60 cells with light weight series
Mono 60 cells with light weight series
Mono 60 cells with light weight series
Mono 60 cells with light weight series
Poly
Poly 72 cells series
72 cells series
Poly
Poly
72 cells series
72 cells series
Back contact 96 cells series
Back contact 96 cells series
Back contact 96 cells series
Back contact 96 cells series
Version 2.
Version 2.
Version 2.2 2 2 2
Version 2.
Note: The content of this manual is subject to change without notice.
© 2014 AU Optronics All Rights Reserved
r
P
h
o
t
o
v
o
r
P
h
o
t
o
v
o
G
u
i
d
e
G
u
i
d
e
l
t
a
i
c
M
o
d
u
l
t
a
i
c
M
o
d
u
PM060PW
PM
060PWX X X X
PM
PM
060PW
060PW
PM060
PM
060M M M M W
W X X X X / / / / PM060M
PM
PM
060
060
W W
PM060M0
PM060M0X X X X
PM060M0
PM060M0
P P P P M072PW
M072PWX X X X /PM072MW
/PM072MWX X X X
M072PW
M072PW
/PM072MW
/PM072MW
PM096B0
PM096B0X X X X
PM096B0
PM096B0
l
e
s
l
e
s
PM060MB B B B X X X X
PM060M
PM060M

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM060PWX and is the answer not in the manual?

Questions and answers

Summary of Contents for BenQ PM060PWX

  • Page 1 Poly 60 cells Poly 60 cells series series PM060PW 060PWX X X X Poly 60 cells Poly 60 cells series series 060PW 060PW Mono 60 cells series Mono 60 cells series PM060 060M M M M W W X X X X / / / / PM060M PM060MB B B B X X X X Mono 60 cells series Mono 60 cells series...
  • Page 2: Table Of Contents

    3.2 Mounting with Clamps ........................10 Chapter 4 Wirin Chapter 4 Wirin Chapter 4 Wirin Chapter 4 Wiring, Connecting and Grounding BenQ Modules g, Connecting and Grounding BenQ Modules g, Connecting and Grounding BenQ Modules g, Connecting and Grounding BenQ Modules........
  • Page 3: Chapter 1 General Information

    Always observe Industry Best Practices when handling, installing, and using this product. This guide is designed for use by trained and certified solar professionals only. BenQ Solar does not assume responsibility for loss, damage or expense resulting from installation, handling or use of this product.
  • Page 4: Guidelines For Safe Handling And Installation

    In addition to the applicable rules and regulations, please follow all guidelines for safe handling and/or installation of BenQ Solar modules. In addition to the guidelines below, always observe industry best practices when handling and/or installing any BenQ Solar module. Save this Installation Guide for future reference.
  • Page 5 BenQ Solar Modules have been listed as Class C according to IEC 61730 BenQ Solar Modules have been listed as Class C according to IEC 61730- - - - 2 2 2 2...
  • Page 6 NOTE: Shading a small/narrow portion of the module (e.g. narrow bands of shade caused by leafless branches or tall grass) can cause local cell temperature to rise, temporarily decreasing overall module output. Removing the source of any narrow bands of shade will prevent these “hot spots” from occurring, and ensure maximum module productivity.
  • Page 7: Performance Of Pv Modules

    BenQ Solar Module Specifications The module electrical ratings are measured under Standard Test Conditions (STC) of 1000W/m2 irradiance with AM 1.5G spectrum and a cell temperature of 25ºC. BenQ Solar modules electrical characteristics depend on module Series and Wattage. Please refer to the tables below to learn more about the characteristics of your module(s).
  • Page 8: Pm060Mw0 / Pm060Mb0 Series

    2.3 PM060MW0 / PM060MB0 Series Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Dimensions (L x W x H): 1639 x 983 x 40 mm (64.52 x 38.7 x 1.57 in) Module Weight: Module Weight: 18.5 kg (41.1 lbs) Module Weight:...
  • Page 9: Pm096B00 Series

    2.6 PM096B00 Series Module Dimensions (L x W x H): Module Dimensions (L x W x H): 1559 x 1046 x 46 mm (61.38 x 41.18 x 1.81 in) Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Weight: Module Weight: Module Weight:...
  • Page 10: Mounting With Screws

    Chapter 3 Chapter 3 Chapter 3 Chapter 3 Mounting Mounting Mounting Mounting Guidelines Guidelines Guidelines Guidelines Modules may be mounted at any angle from horizontal to vertical. Select the appropriate orientation to maximize sunlight exposure. A gap between the module and system structure or ground is required to prevent wire damage and to allow air to circulate behind the module.
  • Page 11: Mounting With Clamps

    5400 Pa design strength. 3.2 Mounting with Clamps • Clips and clamps are not provided by BenQ Solar. • The clamping clips on the side frame must be in parallel – equidistant from the closest module frame corner (see Figure 1).
  • Page 12 • Measurements of D1, D2, D3, and D4 below describe the centerline of the mounting clamp to the closest corner of the module frame. • Clips and clamps are not provided by BenQ Solar. BenQ Solar suggests following conditions below for installation.
  • Page 13 X : equal to module frame height X : equal to module frame height X : equal to module frame height X : equal to module frame height • There are two clamping methods available (see Clamp Location Details below for specific measurements): o Clamp on the long side of the frame (see Figure 2, measurements below) o Clamp on the short side of the frame (see Figure 3, measurements below)
  • Page 14 Figure Figure Figure Figure 2 2 2 2 Long rail mounting clamp range (D1 and D2) Figure Figure Figure Figure 3 3 3 3 Short rail mounting clamp range (D3 and D4)
  • Page 15 Long Rail (5400 Pa) Long Rail (5400 Pa) Short Rail (2400 Pa) Short Rail (2400 Pa) Long Rail (5400 Pa) Long Rail (5400 Pa) Short Rail (2400 Pa) Short Rail (2400 Pa) Model Name PM060PW0 165 mm ( 6.49 in) 245mm (9.64 in) 158 mm (6.22 in) 238 mm (9.36 in)
  • Page 16 PM060PWA / PM060PWB PM060PWA / PM060PWB PM060PWA / PM060PWB PM060PWA / PM060PWB Module Clamp Location Details Module Clamp Location Details Module Clamp Location Details Module Clamp Location Details Long rail Long rail clamping for 5400 Pa design strength: clamp between D1 D1 –...
  • Page 17: Wiring & Connecting

    Wiring, Connecting , Connecting , Connecting and Grounding , Connecting and Grounding and Grounding and Grounding BenQ Modules BenQ Modules BenQ Modules BenQ Modules 4.1 Wiring & Connecting DO NOT do any change or adjustment on the cable of Junction Box.
  • Page 18 • The DC conductors must be properly gauged so that the voltage drop does not exceed 2% of the nominal voltage. • BenQ Solar PV modules are supplied with or without cables, according to where they are ordered. If supplied without cables, it is recommended that cables with cross sections between 4 and 10 mm be used.
  • Page 19: Module Grounding

    Box and connectors. 4.2 Module Grounding BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for inserting the ground contact. The grounding screw and bolt are usually sold separately from the mounting equipment.
  • Page 20: System Grounding (Negative)

    BenQ invalidate BenQ invalidate BenQ invalidate BenQ S S S S olar olar olar olar’s ’s ’s ’s Limited Power Warranty for PV Mo Limited Power Warranty for PV Mo Limited Power Warranty for PV Mo Limited Power Warranty for PV Modules.
  • Page 21: System Grounding (Transformerless Or Positive)

    A series protection fuse of 15A is recommended for each string when module strings are wired in parallel. BenQ Solar recommends the PV conductor, which cross section is 4 mm . External connection boxes can be used to enable greater cable cross section area for long distance transmission.
  • Page 22: Module Cleaning Guidelines

    BenQ Solar PV modules can withstand snow pressure of 2400 Pa.(UL 1703) Please use soft brush lightly removing snow pileup. Do not try to remove frozen snow...
  • Page 23: Module Cleaning Instructions

    Do not leave stagnant water on glass surface. 5.3 Cleaning the Frame BenQ Solar module frames include an anodic oxide coating to increase produce life. The cleaning cycle for regular anodic oxide coatings is generally every six months.
  • Page 24: Iec Certification

    Chapter 6 Certification 6.1 IEC Certification The PV modules provided by BenQ Solar all pass the design qualification and type approval standard IEC 61215 edition 2. The PV modules provided by BenQ Solar all pass the safety qualification standard IEC 61730 certified for application class A.
  • Page 25 版 本 修 訂 日 期 修 訂 內 容 Rev. Rev. Date Update contents 2013/7/23 New issue 2013/7/25 Add section 4.4 transformer less of PM096 2014/04/23 Add new model : PM096B01, PM245P03 Modify the typo of PM096 clamping area 2014/06/30 Add new model : PM060P00 2014/07/01...

Table of Contents