CLUSTER MANAGEMENT MODULE GEN II

PHYSICAL

Max length from Cluster Management Module
to any radio
Max length from Cluster Management Module
to GPS antenna
Dimensions
Weight
Operation Temperature
Overall

AC POWER

100 V – 240 V~, 0.7 A – 0.35 A
Input Voltage
50 Hz – 60 Hz
and Frequency
Note: Applying 230 V to a unit set to 115 V may damage the unit.
Nominal 66 watts, max 92 watts with 8 modules connected to the CMM at max
Input power
cable length.

DC POWER (24V)

Input voltage
15 to 32 VDC, measured at CMM
Nominal 60 watts. Maximum 84 watts with 8 modules connected to the CMM at
Input power
maximum cable length. 9A inrush upon start-up.
If using a typical "24V +/-5%" power supply, ensure that CMM is within 400 cable
Use note
feet (120 m) of the power supply.

DC POWER (12V)

Input voltage
11.5 to 32 VDC, measured at CMM
If using a 12V power source (typically an automobile battery in a test or
emergency situation), use 12 AWG (4 mm
Use note
the CMM, ensure that the CMM is within 10 cable feet (3 m) of the power
supply, and ensure the modules are within 20 cable feet (6 m) of the CMM.

CABLE SPECIFICATIONS

Ethernet, GPS
The use of cables that conform to the operational temperature of the product as
sync, and GPS
well as being UV light protected is mandatory. See Accessories for retailer of
coax cables
cables.

AP_CMM2 User Manual

328 cable feet (100 meters)
100 cable feet (30.5 meters)
17.00" H x 12.88" W x 6.50" D
(43.18 cm H x 32.72 cm W x 16.51 cm D)
25.0 lbs. (11.3 kg)
-40°F to +131°F (-40°C to +55°C)
Meets CE IP44 according to EN60529:2000
2
) wire between the power supply and