Alert List - Yamaha MRX7-D Owner's Manual

Hide thumbs Also See for MRX7-D:
Table of Contents

Advertisement

Appendix

Alert list

This is a list of the alerts that may be indicated in the front panel [PRESET] display.
Alert
number
01–09
The device has not started up correctly.
The internal backup battery has been
10
completely exhausted or is not installed.
The internal backup battery has run
11
extremely low, and it is possible that the
internal memory has been cleared.
The internal backup battery has only a
12
small amount of power remaining.
A problem has occurred with the internal
13
clock, and it has been initialized (January
1, 2000, 0:00).
The current preset saved in internal mem-
14
ory has been lost.
The settings saved in internal memory
15
have been lost.
19
The device has not started up correctly.
An unsupported Mini-YGDAI card is
20
inserted in the slot, or the inserted Mini-
YGDAI card has malfunctioned.
The word clock master has become
21
unlocked.
The digital signal being input to the [YDIF
22
IN] connector is not synchronized to the
word clock of this device.
The digital signal being input to the [YDIF
23
IN] connector is not continuously synchro-
nized to the word clock of this device.
The digital signal being input to the slot is
24
not synchronized to the word clock of this
device.
The digital signal being input to the slot is
25
not continuously synchronized to the word
clock of this device.
The digital signal being input to the Dante
26
connector is not synchronized to the word
clock of this device.
The digital signal being input to the Dante
27
connector is not continuously synchro-
nized to the word clock of this device.
There is a problem with the connection of
30
the [YDIF IN] connector.
40
Duplicate IP addresses.
IP address was not set within 60 seconds
41
of startup.
A device within the MTX/MRX system
42
was not found on the network.
Too many devices are connected to the
43
network.
26
MRX7-D Owner's Manual
Meaning
Turn the power off, then turn on after waiting at least 6 seconds. If this does not
solve the problem, please initialize the memory. Should this also fails, contact your
Yamaha dealer.
When you turn off the power, the current settings will be lost, and will return to the
default values. Please stop use immediately, and contact your Yamaha dealer.
When you turn off the power, the current settings will be lost, and will return to the
default values. Please stop use immediately, and contact your Yamaha dealer.
This does not affect the operation of the device. However, if you continue using the
device, the settings may be lost and reset to the default values. Contact your
Yamaha dealer as soon as possible.
If this occurs each time you turn on the power, it is possible that the internal
backup battery has run down or that the device has malfunctioned. Contact your
Yamaha dealer.
If this occurs only once, an abnormality was detected with the clock setting and it
was initialized; use MTX-MRX Editor to set the time.
Recall the preset. If this does not solve the problem, contact your Yamaha dealer.
Either the internal backup battery has run low, or the device has malfunctioned.
Contact your Yamaha dealer.
Contact your Yamaha dealer.
Replace the card with a supported Mini-YGDAI card or check that the supported
Mini-YGDAI card is working correctly in another Host.
Make sure that the word clock signal is being input correctly.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
Either input a signal that is synchronized, or specify the slot as the word clock
master.
Either input a signal that is synchronized, or specify the Dante as the word clock
master.
Make sure that YDIF cables are properly connected.
Use cables that meet the required specifications.
Change the IP addresses so that there are no duplicates.
Please check rear panel DIP switch 6 (IP Setting). If DIP switch 6 is set to "PC,"
use MTX-MRX Editor or DHCP server to specify the device IP address.
Power-on all devices in the system, and make sure that they are correctly con-
nected to the network.
Reduce the number of devices connected to the network.
Response