REA ScanCheck 3n Operating Manual

REA ScanCheck 3n Operating Manual

Bar code verification unit
Hide thumbs Also See for ScanCheck 3n:
Table of Contents

Advertisement

Streamlining • Development • Automation
Electronic Devices and Systems
© REA Elektronik GmbH
D-64367 Mühltal-Waschenbach
+49 (0) 6154-638 0
REA ScanCheck 3n
Bar Code Verification Unit
Operating Manual
Document Version
SC3-GUI-Version from
TD-GPT-Printer version
Verifier-Version
REA ScanCheck 3 - August 2010
www.rea-verifier.de
REA
1.1.0 -20100530-
1.0.10.7
1.20
1.0.10.14
Elektronik
GmbH
Page 1 of 89

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ScanCheck 3n and is the answer not in the manual?

Questions and answers

David Nyberg
February 26, 2025

When I try do calibrate my REA Scancheck 3 I get the error code: "Error during adjustment [0x40081009] What should I do?

Summary of Contents for REA ScanCheck 3n

  • Page 1 REA ScanCheck 3n Bar Code Verification Unit Operating Manual Document Version 1.1.0 -20100530- SC3-GUI-Version from 1.0.10.7 TD-GPT-Printer version 1.20 Verifier-Version 1.0.10.14 © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 1 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 2 Updating with the "Update Program" from the REA CD-ROM ........27 Calibrating the REA ScanCheck 3n ................29 3.9.1 Calibrating the REA ScanCheck 3n for 6, 8 and 10 mil Apertures ......30 3.9.2 Calibrating the REA ScanCheck 3n for 20 mil Aperture..........31 3.9.3...
  • Page 3 4.1.1 Instructions for Correct Execution of Code Evaluations..........35 First Measurement of Bar Codes ................36 4.2.1 Depiction of a Code Evaluation on the REA ScanCheck 3 ........37 4.2.1.1 Quick Display with LED and Acoustic Signaling ............37 4.2.1.2 Evaluation of an ISO/IEC 15416 Verification - 1st Screen .........
  • Page 4 Appendix Glossary of Technical Code Verification Terms ........79 Appendix Technical Data - REA ScanCheck 3n............82 Appendix Technical Data - PoE Power Supply / Charger for REA ScanCheck 3n..84 © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 4 of 89 D-64367 Mühltal-Waschenbach...
  • Page 5 Intellectual Property Provision................... 85 Environmental Protection ..................85 Appendix - Warranty Terms ..................86 Appendix - CE Conformity Statement for REA ScanCheck 3 ........87 Appendix ISO/IEC Conformity Certificate for REA ScanCheck 3....... 88 Appendix - Conformity Confirmation for Verifier Calibration Card......89 ©...
  • Page 6: Introduction

    GmbH Introduction The REA ScanCheck 3n is a mobile bar code verification unit for zero-contact inspection of the quality of printed linear and stacked bar codes. It can be used in a portable manner on site for quick evaluation. The verification result "good" or "error" is represented both by acoustic signals and visually by means of multi-colored LED displays.
  • Page 7: Documentation Conventions

    Before starting and operating the REA product, be sure to read and observe the operating instructions and especially the safety instructions very carefully.
  • Page 8: Determination Of Serial Numbers On The Rea Product

    Determination of Serial Numbers on the REA Product For contact with the manufacturer or a system partner, it is important to indicate the precise type and the serial number of the affected REA product. This information can be found on the company label on the hardware together with the article number.
  • Page 9: The Delivery Components Of The Rea Scancheck 3N

    GmbH The Delivery Components of the REA ScanCheck 3n In the standard version, the REA ScanCheck 3n is supplied in the following configuration and always in a specialized transport box with form insert. A REA ScanCheck 3n consists of the following components...
  • Page 10 Optional code types (internal software option usable via activation code) • All software options can be freely activated and operated exclusively with the serial number of a REA ScanCheck 3n. A REA ScanCheck 3n will not work with TransWin32 software or another software option without the corresponding activation code if the activation key is not correct.
  • Page 11: Startup Of The Rea Scancheck 3N

    GmbH Startup of the REA ScanCheck 3n Special installation on the REA ScanCheck 3n is no longer required. It is delivered ready to operate. The unit is configured for a standard presetting and can inspect and evaluate most code types according to the GS1 standard requirements immediately after activation.
  • Page 12: Activation And Deactivation Of The Rea Scancheck 3N

    Only then does the main screen appear as shown at right. Once the REA ScanCheck 3 has been activated, it can be deactivated by pressing the <ON> button again.The display then opens the menu window for various modes.
  • Page 13: Reactivation Of The Rea Scancheck 3N After Power Supply Failure

    Electronic Devices and Systems GmbH The REA ScanCheck 3n can also be completely deactivated from this menu with the key sequence <ON>, <OK Enter>. If a software update is carried out with a USB memory stick in this operating mode, this can be started with the command sequence <6>, <OK Enter>.
  • Page 14: Changing Presets On The Rea Scancheck 3N

    English Day and Time: Unchanged Network Settings: Unchanged Company/User Unit name, user name, company information are overwritten with the REA factory Information: specifications Password: Overwritten with spaces Format of Report Print- Long version complete, prints all elements that can be selected Out: ©...
  • Page 15: Change Menu Language Selection

    (English, in this case). The provision of additional languages is also scheduled for future software versions. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 15 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 16: Change Data Output Parameters

    The corresponding measurement reports are then always printed when the button <Print L> or <Print S> is pressed on the REA ScanCheck If the unit is connected via the connection cable to the PC on which the •...
  • Page 17: Operating Rea Scancheck 3N With Report Printer

    Operation with other printers is not possible and not intended. The predecessor model REA ScanCheck 3, which could be connected to a PC via USB, was supplied with a 9V power supply. The printer power supply and the ScanCheck 3 power supply could be interchanged in this configuration.
  • Page 18: Rea Scancheck 3N With Pc Evaluation Software

    TCP-IP protocol. The connection options are described below. The software REA TransWin32 is not included in the standard scope of delivery of a REA ScanCheck 3n. If REA TransWin 32 was ordered, the necessary license key is already stored in the verification unit ex factory.
  • Page 19: Connection Of The Rea Scancheck 3N To Power Supply

    No driver installation is required for the REA ScanCheck 3n. No network configuration must be made, either, as this normally takes place automatically (basic setting ex factory). The REA ScanCheck 3n is connected to the PC via the network. The cabling can be implemented as follows: The PC and the REA ScanCheck 3n are each connected to one network connection socket in •...
  • Page 20: Firewall

    • switch is connected to the network (DHCP mode). DHCP Mode: The PC and the REA ScanCheck 3n are in the company network and obtain the network configuration via the DHCP server. This mode is active in the factory settings.
  • Page 21: Technical Functionality Test Of A Network Connection

    After a few seconds, new text lines appear with specifications on the response times of the pinged IP address or error messages. With this test, it can be determined whether the TCP/IP connection between the IP address of the REA verification unit and the IP address of the PC network interface is generally functioning.
  • Page 22: Use Of Extension Plates On The Scancheck 3

    GmbH Use of Extension Plates on the ScanCheck 3 Transparent extension plates with various cut-out widths can be used as accessories for the REA ScanCheck 3n. To do so, the standard-installed trapezoidal transparent base plate is removed and replaced by one of the extension plates.
  • Page 23: Charging The Batteries

    The charge time equals at least approximately 4 hours with empty batteries. During charging, the right- hand green LED underneath the display with the label "charge" lights up on the REA ScanCheck 3n. It goes out once the charge is complete and no further charging is carried out or if the power supply is emitting no voltage.
  • Page 24: Storage And Transport

    GmbH Storage and Transport The REA ScanCheck 3n is a valuable verification unit with highly precise optical and electronic assemblies. It should always be stored and transported protected in the custom-fit foam forms in the supplied original box or in the optionally available transport case. Both the unit parts and additional accessories are optimally protected against dust collection and shock and damage.
  • Page 25: Updating Operating Software In Rea Scancheck 3

    This software is always up to date upon delivery. REA will work on improvements and updates in the future and provide these to customers in order to update their units. REA places the latest versions on the Internet in the Support area for download.
  • Page 26 GmbH Fig.: REA ScanCheck 3n with connected USB memory stick In order to start the update program on the REA ScanCheck 3n, activate the REA ScanCheck 3n with the <ON> button and wait until the start screen is displayed. Then select and press the following keys in sequence: <Setup>, <3>...
  • Page 27: Updating With The "Update Program" From The Rea Cd-Rom

    UpdateServer.Exe. It can be downloaded separately from the enclosed CD-ROM to a PC with the Windows operating system or started from the program REA TransWin32 from the menu bar (see operating instructions of REA TransWin32 for installation instructions).
  • Page 28 REA verification units by selecting it with a click on the left mouse button. The REA ScanCheck 3n appears in the list e.g. with the name "SC3n_PoE-Master." If more than one unit is listed with the same name, the...
  • Page 29: Calibrating The Rea Scancheck 3N

    The calibration card should always be stored protected, may not be contaminated and should not be touched on its surface. It should be replaced every 1 to 2 years by a new, original REA calibration card. If the card was previously damaged or dirtied, immediate replacement is required.
  • Page 30: Calibrating The Rea Scancheck 3N For 6, 8 And 10 Mil Apertures

    GmbH 3.9.1 Calibrating the REA ScanCheck 3n for 6, 8 and 10 mil Apertures The calibration process can be selected from the Setup Menu. The key sequence <Setup>, <Calibration> with the arrow buttons and <OK Enter> or the buttons <Setup> and <2> opens the Calibration input window.
  • Page 31: Calibrating The Rea Scancheck 3N For 20 Mil Aperture

    A dimensions calibration with the sample code on the calibration card is no longer required with REA ScanCheck 3n. The unit was already calibrated in the factory to the corresponding size parameters and adjusted by means of a factory calibration.
  • Page 32: Verification Tool Monitoring

    For this purpose, there are two test codes on the REA ScanCheck 3 calibration card that were printed there with high precision. The left-hand EAN-13 code, with a nominal size of 100%, should always be used for the verification tool monitoring.
  • Page 33 (correspond. Z-Module 660 µm +/- 6.6µm). A size error is only displayed if the measured value is greater than 201%. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 33 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 34: Operation Of The Rea Scancheck 3N

    GmbH Operation of the REA ScanCheck 3n The following chapters describe the operation and correct handling of the REA ScanCheck 3n. It must always be noted that bar codes are measured and verified with the REA ScanCheck 3n. The measurement results should therefore be comparable and repeatable. To this end, it is necessary that all measurements also be carried out under uniform conditions and with a calibrated verification unit.
  • Page 35: Instructions For Correct Execution Of Code Evaluations

    6. Measurements in direct sunlight are to be avoided because the measurements are falsified. 7. The bar code to be verified should be located centered in front of the REA ScanCheck 3, in order to obtain the best measurement accuracy (see the positioning help on the calibration card).
  • Page 36: First Measurement Of Bar Codes

    Electronic Devices and Systems GmbH First Measurement of Bar Codes To measure bar codes, the REA Scan Check 3n must be calibrated (see Chapter 3.9). After activation of the REA ScanCheck 3n, the system requires approx. 15 seconds for initialization of the programs.
  • Page 37: Depiction Of A Code Evaluation On The Rea Scancheck 3

    Electronic Devices and Systems GmbH 4.2.1 Depiction of a Code Evaluation on the REA ScanCheck 3 4.2.1.1 Quick Display with LED and Acoustic Signaling The three center LEDs directly underneath the name represent the measurement results as a quick display with...
  • Page 38: Evaluation Of An Iso/Iec 15416 Verification - 5Th Screen Optional Parameters

    The arrow keys can be used to page up or down through the individual display pages of the evaluation views. The detailed description and interpretation of the individual measurement results and parameters can be found in the separately available training manual from REA Elektronik GmbH. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 38 of 89 D-64367 Mühltal-Waschenbach...
  • Page 39: Adjustments / Selection Of The Correct Aperture

    The measurement should be made with a compatible aperture for correct code verification. The size of the aperture should always be smaller than 80% of the X-module size of the subject and is always indicated in the measurement results. The REA ScanCheck 3n offers code verification with a selection of four different aperture settings.
  • Page 40 A corresponding error message otherwise occurs. After correct installation of the adapter and positioning of the operating part, the REA ScanCheck 3n automatically recognizes the setting for the "20 mil aperture" and indicates this on the display. If one of the two presets were not carried out correctly, the screen shows a corresponding error message: "False Aperture...
  • Page 41 A smaller aperture remains without effect if the bar code is of good quality. When using smaller apertures, any defects present have greater effect on the "defects" parameter. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 41 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 42: Settings / Button Functions / Setup Menu

    If large codes, such as 100% ITF-14 codes including the bright field zones are measured, it can occur that the width of the scan beam from the REA ScanCheck 3n is not sufficient in the aperture settings 6, 8 or 10 mil.
  • Page 43 If you are on the screen pages in the Setup menu, the last selection setting is immediately accepted and the program jumps back to the higher menu level. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 43 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 44: Buttons With Special Functions

    <Print S> -Button: This function of this button can only be called up if a measurement result is shown in the display. If the REA ScanCheck 3n is connected to the REA TD-GPT-U printer, the verification report is printed on this printer upon activating the "Print" button.
  • Page 45 By lightly pressing down with a fingertip or a ballpoint pen tip, you will feel the switch-click with which a RESET is triggered (see Chapter 4.4.2). © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 45 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 46: Setup Menu Structure

    All adjustment functions can be called up by pressing the <Setup> button. If the REA ScanCheck 3n is operated with the optionally available PC software REA TransWin32, the complete configuration can also be made from the PC via corresponding windows and also saved in the future as a complete preset profile in a profile manager or called up from there.
  • Page 47: Setup Sub-Menu 2 Calibration

    <Print (L)> or <Print (S)>. Alternatively, the selected measurement report is displayed in the PC software REA TransWin32. <Open> Displays the topmost of all highlighted measurement reports on the display of the REA ScanCheck 3n. <Delete> Deletes all selected files If a great many reports are saved, this can heavily reduce the response time of the unit.
  • Page 48 Settings in the User Search menu do not change any settings in the other two selection menus. When decoding all other non-selected code types, the unit produces this error message upon a verification: "Not decodable." © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 48 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 49: Code Selection

    Code 2 from 5 INT). If such a code type is selected, the incompatible code type is automatically deselected. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 49 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 50: Ean-13 - Additional Verification Criteria

    - a publication, in this case - but still differentiate the editions clearly from one another with differing add on numbers. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 50 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 51 GS1 Global, by way of contrast, specifies a 5-digit Add On. The instore verification function of the REA ScanCheck 3n is flexible and allows for the combination of all settings. The table lists all coding possibilities from "20" to "29."...
  • Page 52: Upc-A Code - Additional Verification Criteria

    13 characters, the leading character "2" must always be decoded as "02." The REA ScanCheck 3n decodes the complete information with 13 places. For that reason, the leading character in the left screen is shown with "02" instead of "2."...
  • Page 53: Upc-E Code - Additional Verification Criteria

    12-place UPC-A Code extended to 12 characters when a 6-place UPC-E Code is read. REA bar code verification units always display only the actual 6 decoded characters of the code. Later versions will display the code extended to 12 characters.
  • Page 54: The Code 128 Family

    The GS1-128 Code (previously EAN 128) is a special form of Code 128 in which a special data structure is applied. This was specified by the GS1 Global organization. The REA ScanCheck 3n can also verify these special data structures and several additional properties of this code type.
  • Page 55 In verification this date does not create an error message because it is still within the specified period. Example (Entries for the Application Identifier 15 and 17) Selected time period according to the current date of the internal clock of the REA ScanCheck 3: From...
  • Page 56: The Gs1 Databar Code Family

    If the UPU or HIBC functions were activated, deactivation of the verification character function has no meaning because a verification character control is always specified and contained in these code types. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 56 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 57: Code 39 – Full Ascii - Additional Verification Criteria

    In both cases, the HIBC code begins with a "+" character, followed by a specified data structure. The REA ScanCheck 3n verifies whether the "+" character exists and whether the verification character is correct. It is planned that later software versions will also additionally verify the data structure.
  • Page 58: Codabar - Additional Verification Criteria (Optional)

    670 nm. For this reason, it is urgently advised to use only color combinations that can also be easily read by red light scanners (630 nm to 680 nm). The REA ScanCheck 3n always uses a laser light source with a wavelength of 670 nm. The aperture should equal 6 mil. The code size X is permissible between 0.187 mm and 0.450 mm.
  • Page 59: Itf-14 Code - Additional Verification Criteria

    The ISO standard allows ratios of 1:2 to 1:3 in any case and without the restrictions as with ANSI. This code can only be selected if ITF-14 Code is not activated (see above). © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 59 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 60 0.635 mm (narrow), 0.787 mm (medium) and 1.02 mm (large). If "automatic" is selected, the REA ScanCheck 3n calculates the deviation to the next standard size. The use of two different stop characters is permitted for Plessey Code: One is used if the code may only be read from left to right.
  • Page 61: Pharma And Mini Pharma Code - Additional Verification Criteria

    It is also described as binary code, Laetus Code, Sick Code or Weber Code. REA bar code verification units use the specifications of the Laetus company for verifying Pharma Codes. The specifications of other manufacturers are slightly different (e.g. the Sick Code).
  • Page 62: Setup Menu 3 Settings - 3 Evaluation - Second Sub-Menu

    In the factory setting, relative values in % of the respectively permissible tolerance and with a rounding of 5% are preset. A multiple measurement can be cancelled at any time by pressing the number button <3> on the REA ScanCheck 3n (see Chapter 4.4.2).
  • Page 63: Setup Menu 3 Settings - 3 Evaluation - Fourth Sub-Menu

    Z-Module: Is the measured module width in a bar code. This is a unique size information in µm for all bar code symbologies. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 63 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 64 Only the code content is compared, not the code symbology. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 64 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 65: Setup Menu 3 Settings - 4 Unit Configuration With 8 Sub-Menus

    USB connection to a PC or to the connected printer. All operating settings and the verification reports saved up to that point are saved in a RESET-proof memory. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 65 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 66 The display shows the main screen and the USB data connection to the PC or to the printer can be reactivated. In the PC application REA TransWin32, the connection to the REA ScanCheck 3 can be automatically reestablished.
  • Page 67: Setup Menu 3 Settings - 4 Unit Configuration - 2 Output Parameters

    This can be opened by REA Elektronik for verification purposes and evaluated. Memory options All measurement reports can be saved both in the memory of the REA ScanCheck 3n as well as on a PC with the REA TransWin32 software.
  • Page 68 If in the settings for the output parameters in the menu the print-out of the order number was not deactivated, this information is also specified in the report print-out (see Chapter 4.6.3.4 ff). © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 68 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 69: Setup Menu 3 Settings - 4 Unit Configuration - 3 Options

    4.6.3.4.4 Setup Menu 3 Settings - 4 Unit Configuration - 4 Date and Time The values for the internal system clock in the REA ScanCheck 3n can be inspected and corrected in this menu window. Incorrect data can lead to incorrect information in the evaluations. The system clock information is included in every measurement report.
  • Page 70: Setup Menu 3 Settings - 4 Unit Configuration - 5 Network Parameters

    The correct password must always be entered for access to the settings on the password level. The REA ScanCheck 3n should be able to be secured against unauthorized changes to all settings by entering an access key, repeating it in the confirmation field and accepting with <Store>.
  • Page 71: Setup Menu 3 Settings - 4 Unit Configuration - 7 Company/User Information

    REA TD-GPT-U printer can be made. These settings do not change the depiction of the measurement results in the PC software REA TransWin32 and its print-out. The detailed report (long report) is only printed if the <Print L>...
  • Page 72: Setup Menu 3 Settings - 5 Code Comparator (Option Only)

    Only the code content is compared, not the code symbology. Operation with the REA ScanCheck 3 can be enabled with a license key. The respective function can be activated by filling in the box.
  • Page 73: Setup Menu 5 Article Trigger (Option For Article Database)

    Electronic Devices and Systems GmbH The optional software expansion "REA Article Database 32" is required for this function. With the help of the PC program, new article data sets can be created in a database on a PC, existing ones can be edited and then provided for export to the REA ScanCheck 3n.
  • Page 74: Setup Menu 3 Settings - 9 Language

    © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 74 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 75: Setup Menu 4 Document Editing "Order Number

    Incorrectly entered characters can be deleted with the <Del.> button and overwritten. The inputs can be accepted with the <Store> button. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 75 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 76: Setup Menu 5 System Information

    - Version of decoder and evaluation software (1.0.10.14 in this - case) Serial number of the REA ScanCheck 3n (003.207.106-04015-7 in this case) The assigned name (SC3_PoE in this case) stands under unit name. The assigned user name (SC_3 User in this case) These specifications serve as information on the software versions operated with the unit and are always required when technical support is requested.
  • Page 77: Appendix Standards And Literature On Bar Code Verification Units

    EN 1556 Bar coding – terminology EN 796 Bar coding – Symbology identifier ANSI/UCC6 Application Identifier Standard for Shipping Containers © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 77 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 78 Information technology – Automatic Identification and data capture techniques - Bar code master test specifications Acquisition source for standards: Beuth Verlag GmbH, Burggrafenstr. 7, 10772 Berlin, http://www.beuth.de © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 78 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 79 The width of the individual elements can be indicated in module X or in multiples of the X module. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 79 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0...
  • Page 80 Smallest image element that in combination with others forms a complete graphic. Smallest image element of a CMOS camera as © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 80 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 81 Z-Modul Z module The average measured width of the narrowest element of a bar/stack code © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 81 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 82: Appendix Technical Data - Rea Scancheck 3N

    Streamlining • Development • Automation Elektronik Electronic Devices and Systems GmbH Appendix Technical Data - REA ScanCheck 3n Charger voltage supply via supplied power-over-Ethernet Input: DC 48 V / 0.5 A operation, 0.32 A max. charge current Battery operation 4 x 1.2 V / 2,500 mAH NiMH batteries, rechargeable...
  • Page 83 Cleaning of lens and laser emission window only with special cloth for optical lenses. Battery maintenance. © REA Elektronik GmbH REA ScanCheck 3 - August 2010 Page 83 of 89 D-64367 Mühltal-Waschenbach +49 (0) 6154-638 0 www.rea-verifier.de...
  • Page 84: Appendix Technical Data - Poe Power Supply / Charger For Rea Scancheck 3N

    Elektronik Electronic Devices and Systems GmbH Appendix Technical Data - PoE Power Supply / Charger for REA ScanCheck 3n Input voltage 100 –240 Volt AC / 50 – 60 Hz, 0.32 A ~ Connection via 3-pole cold unit plug socket and network connection line with grounding plug.
  • Page 85: Intellectual Property Provision

    "REA_Verifier“, Password: "REA-C36754“. Protected Trademarks All of the product names that are known to REA to be protected were correspondingly marked with the following symbol in this document. Microsoft®, Embedded Visual Tools®, are registered trademarks of the Microsoft Corporation in the USA and other countries;...
  • Page 86: Appendix - Warranty Terms

    Express deliveries can be made upon request. The additional cost incurred for this will always be charged. If the unit is not sent to REA in the original packaging, REA will use new original packaging for the return shipment and this will be charged.
  • Page 87: Appendix - Ce Conformity Statement For Rea Scancheck 3

    Streamlining • Development • Automation Elektronik Electronic Devices and Systems GmbH Appendix - CE Conformity Statement for REA ScanCheck 3 EG - Konformitätserklärung Declaration of conformity Déclaration de conformité Das Unternehmen / The company / La société REA Elektronik GmbH Teichwiesenstraße 1...
  • Page 88: Appendix Iso/Iec Conformity Certificate For Rea Scancheck 3

    • conformance specification – Part 1 Linear symbols The REA ScanCheck 3n is a unit that fulfills the minimum functionality (mandatory) and the optional functions (optional) of this standard. ENV 12647 Bar coding - verification requirements for bar code verification units •...
  • Page 89: Appendix - Conformity Confirmation For Verifier Calibration Card

    It should be replaced no later than 2 years after delivery by a new original calibration card. Verification Tool Monitoring The REA ScanCheck 3n must be inspected in connection with a verification tool monitoring regularly every 4 to 8 weeks. This should be done using the reference code on this calibration card, directly after a calibration and in reference and comparison to the enclosed reference verification report.

Table of Contents