4.1.1 Instructions for Correct Execution of Code Evaluations..........35 First Measurement of Bar Codes ................36 4.2.1 Depiction of a Code Evaluation on the REA ScanCheck 3 ........37 4.2.1.1 Quick Display with LED and Acoustic Signaling ............37 4.2.1.2 Evaluation of an ISO/IEC 15416 Verification - 1st Screen .........
GmbH Introduction The REA ScanCheck 3n is a mobile bar code verification unit for zero-contact inspection of the quality of printed linear and stacked bar codes. It can be used in a portable manner on site for quick evaluation. The verification result "good" or "error" is represented both by acoustic signals and visually by means of multi-colored LED displays.
Before starting and operating the REA product, be sure to read and observe the operating instructions and especially the safety instructions very carefully.
Determination of Serial Numbers on the REA Product For contact with the manufacturer or a system partner, it is important to indicate the precise type and the serial number of the affected REA product. This information can be found on the company label on the hardware together with the article number.
GmbH The Delivery Components of the REA ScanCheck 3n In the standard version, the REA ScanCheck 3n is supplied in the following configuration and always in a specialized transport box with form insert. A REA ScanCheck 3n consists of the following components...
Page 10
Optional code types (internal software option usable via activation code) • All software options can be freely activated and operated exclusively with the serial number of a REA ScanCheck 3n. A REA ScanCheck 3n will not work with TransWin32 software or another software option without the corresponding activation code if the activation key is not correct.
GmbH Startup of the REA ScanCheck 3n Special installation on the REA ScanCheck 3n is no longer required. It is delivered ready to operate. The unit is configured for a standard presetting and can inspect and evaluate most code types according to the GS1 standard requirements immediately after activation.
Only then does the main screen appear as shown at right. Once the REA ScanCheck 3 has been activated, it can be deactivated by pressing the <ON> button again.The display then opens the menu window for various modes.
Electronic Devices and Systems GmbH The REA ScanCheck 3n can also be completely deactivated from this menu with the key sequence <ON>, <OK Enter>. If a software update is carried out with a USB memory stick in this operating mode, this can be started with the command sequence <6>, <OK Enter>.
The corresponding measurement reports are then always printed when the button <Print L> or <Print S> is pressed on the REA ScanCheck If the unit is connected via the connection cable to the PC on which the •...
Operation with other printers is not possible and not intended. The predecessor model REA ScanCheck 3, which could be connected to a PC via USB, was supplied with a 9V power supply. The printer power supply and the ScanCheck 3 power supply could be interchanged in this configuration.
TCP-IP protocol. The connection options are described below. The software REA TransWin32 is not included in the standard scope of delivery of a REA ScanCheck 3n. If REA TransWin 32 was ordered, the necessary license key is already stored in the verification unit ex factory.
No driver installation is required for the REA ScanCheck 3n. No network configuration must be made, either, as this normally takes place automatically (basic setting ex factory). The REA ScanCheck 3n is connected to the PC via the network. The cabling can be implemented as follows: The PC and the REA ScanCheck 3n are each connected to one network connection socket in •...
• switch is connected to the network (DHCP mode). DHCP Mode: The PC and the REA ScanCheck 3n are in the company network and obtain the network configuration via the DHCP server. This mode is active in the factory settings.
After a few seconds, new text lines appear with specifications on the response times of the pinged IP address or error messages. With this test, it can be determined whether the TCP/IP connection between the IP address of the REA verification unit and the IP address of the PC network interface is generally functioning.
GmbH Use of Extension Plates on the ScanCheck 3 Transparent extension plates with various cut-out widths can be used as accessories for the REA ScanCheck 3n. To do so, the standard-installed trapezoidal transparent base plate is removed and replaced by one of the extension plates.
The charge time equals at least approximately 4 hours with empty batteries. During charging, the right- hand green LED underneath the display with the label "charge" lights up on the REA ScanCheck 3n. It goes out once the charge is complete and no further charging is carried out or if the power supply is emitting no voltage.
GmbH Storage and Transport The REA ScanCheck 3n is a valuable verification unit with highly precise optical and electronic assemblies. It should always be stored and transported protected in the custom-fit foam forms in the supplied original box or in the optionally available transport case. Both the unit parts and additional accessories are optimally protected against dust collection and shock and damage.
This software is always up to date upon delivery. REA will work on improvements and updates in the future and provide these to customers in order to update their units. REA places the latest versions on the Internet in the Support area for download.
Page 26
GmbH Fig.: REA ScanCheck 3n with connected USB memory stick In order to start the update program on the REA ScanCheck 3n, activate the REA ScanCheck 3n with the <ON> button and wait until the start screen is displayed. Then select and press the following keys in sequence: <Setup>, <3>...
UpdateServer.Exe. It can be downloaded separately from the enclosed CD-ROM to a PC with the Windows operating system or started from the program REA TransWin32 from the menu bar (see operating instructions of REA TransWin32 for installation instructions).
Page 28
REA verification units by selecting it with a click on the left mouse button. The REA ScanCheck 3n appears in the list e.g. with the name "SC3n_PoE-Master." If more than one unit is listed with the same name, the...
The calibration card should always be stored protected, may not be contaminated and should not be touched on its surface. It should be replaced every 1 to 2 years by a new, original REA calibration card. If the card was previously damaged or dirtied, immediate replacement is required.
GmbH 3.9.1 Calibrating the REA ScanCheck 3n for 6, 8 and 10 mil Apertures The calibration process can be selected from the Setup Menu. The key sequence <Setup>, <Calibration> with the arrow buttons and <OK Enter> or the buttons <Setup> and <2> opens the Calibration input window.
A dimensions calibration with the sample code on the calibration card is no longer required with REA ScanCheck 3n. The unit was already calibrated in the factory to the corresponding size parameters and adjusted by means of a factory calibration.
For this purpose, there are two test codes on the REA ScanCheck 3 calibration card that were printed there with high precision. The left-hand EAN-13 code, with a nominal size of 100%, should always be used for the verification tool monitoring.
GmbH Operation of the REA ScanCheck 3n The following chapters describe the operation and correct handling of the REA ScanCheck 3n. It must always be noted that bar codes are measured and verified with the REA ScanCheck 3n. The measurement results should therefore be comparable and repeatable. To this end, it is necessary that all measurements also be carried out under uniform conditions and with a calibrated verification unit.
6. Measurements in direct sunlight are to be avoided because the measurements are falsified. 7. The bar code to be verified should be located centered in front of the REA ScanCheck 3, in order to obtain the best measurement accuracy (see the positioning help on the calibration card).
Electronic Devices and Systems GmbH First Measurement of Bar Codes To measure bar codes, the REA Scan Check 3n must be calibrated (see Chapter 3.9). After activation of the REA ScanCheck 3n, the system requires approx. 15 seconds for initialization of the programs.
Electronic Devices and Systems GmbH 4.2.1 Depiction of a Code Evaluation on the REA ScanCheck 3 4.2.1.1 Quick Display with LED and Acoustic Signaling The three center LEDs directly underneath the name represent the measurement results as a quick display with...
The measurement should be made with a compatible aperture for correct code verification. The size of the aperture should always be smaller than 80% of the X-module size of the subject and is always indicated in the measurement results. The REA ScanCheck 3n offers code verification with a selection of four different aperture settings.
Page 40
A corresponding error message otherwise occurs. After correct installation of the adapter and positioning of the operating part, the REA ScanCheck 3n automatically recognizes the setting for the "20 mil aperture" and indicates this on the display. If one of the two presets were not carried out correctly, the screen shows a corresponding error message: "False Aperture...
If large codes, such as 100% ITF-14 codes including the bright field zones are measured, it can occur that the width of the scan beam from the REA ScanCheck 3n is not sufficient in the aperture settings 6, 8 or 10 mil.
<Print S> -Button: This function of this button can only be called up if a measurement result is shown in the display. If the REA ScanCheck 3n is connected to the REA TD-GPT-U printer, the verification report is printed on this printer upon activating the "Print" button.
All adjustment functions can be called up by pressing the <Setup> button. If the REA ScanCheck 3n is operated with the optionally available PC software REA TransWin32, the complete configuration can also be made from the PC via corresponding windows and also saved in the future as a complete preset profile in a profile manager or called up from there.
<Print (L)> or <Print (S)>. Alternatively, the selected measurement report is displayed in the PC software REA TransWin32. <Open> Displays the topmost of all highlighted measurement reports on the display of the REA ScanCheck 3n. <Delete> Deletes all selected files If a great many reports are saved, this can heavily reduce the response time of the unit.
Page 51
GS1 Global, by way of contrast, specifies a 5-digit Add On. The instore verification function of the REA ScanCheck 3n is flexible and allows for the combination of all settings. The table lists all coding possibilities from "20" to "29."...
13 characters, the leading character "2" must always be decoded as "02." The REA ScanCheck 3n decodes the complete information with 13 places. For that reason, the leading character in the left screen is shown with "02" instead of "2."...
12-place UPC-A Code extended to 12 characters when a 6-place UPC-E Code is read. REA bar code verification units always display only the actual 6 decoded characters of the code. Later versions will display the code extended to 12 characters.
The GS1-128 Code (previously EAN 128) is a special form of Code 128 in which a special data structure is applied. This was specified by the GS1 Global organization. The REA ScanCheck 3n can also verify these special data structures and several additional properties of this code type.
Page 55
In verification this date does not create an error message because it is still within the specified period. Example (Entries for the Application Identifier 15 and 17) Selected time period according to the current date of the internal clock of the REA ScanCheck 3: From...
In both cases, the HIBC code begins with a "+" character, followed by a specified data structure. The REA ScanCheck 3n verifies whether the "+" character exists and whether the verification character is correct. It is planned that later software versions will also additionally verify the data structure.
670 nm. For this reason, it is urgently advised to use only color combinations that can also be easily read by red light scanners (630 nm to 680 nm). The REA ScanCheck 3n always uses a laser light source with a wavelength of 670 nm. The aperture should equal 6 mil. The code size X is permissible between 0.187 mm and 0.450 mm.
Page 60
0.635 mm (narrow), 0.787 mm (medium) and 1.02 mm (large). If "automatic" is selected, the REA ScanCheck 3n calculates the deviation to the next standard size. The use of two different stop characters is permitted for Plessey Code: One is used if the code may only be read from left to right.
It is also described as binary code, Laetus Code, Sick Code or Weber Code. REA bar code verification units use the specifications of the Laetus company for verifying Pharma Codes. The specifications of other manufacturers are slightly different (e.g. the Sick Code).
In the factory setting, relative values in % of the respectively permissible tolerance and with a rounding of 5% are preset. A multiple measurement can be cancelled at any time by pressing the number button <3> on the REA ScanCheck 3n (see Chapter 4.4.2).
Page 66
The display shows the main screen and the USB data connection to the PC or to the printer can be reactivated. In the PC application REA TransWin32, the connection to the REA ScanCheck 3 can be automatically reestablished.
This can be opened by REA Elektronik for verification purposes and evaluated. Memory options All measurement reports can be saved both in the memory of the REA ScanCheck 3n as well as on a PC with the REA TransWin32 software.
4.6.3.4.4 Setup Menu 3 Settings - 4 Unit Configuration - 4 Date and Time The values for the internal system clock in the REA ScanCheck 3n can be inspected and corrected in this menu window. Incorrect data can lead to incorrect information in the evaluations. The system clock information is included in every measurement report.
The correct password must always be entered for access to the settings on the password level. The REA ScanCheck 3n should be able to be secured against unauthorized changes to all settings by entering an access key, repeating it in the confirmation field and accepting with <Store>.
REA TD-GPT-U printer can be made. These settings do not change the depiction of the measurement results in the PC software REA TransWin32 and its print-out. The detailed report (long report) is only printed if the <Print L>...
Only the code content is compared, not the code symbology. Operation with the REA ScanCheck 3 can be enabled with a license key. The respective function can be activated by filling in the box.
Electronic Devices and Systems GmbH The optional software expansion "REA Article Database 32" is required for this function. With the help of the PC program, new article data sets can be created in a database on a PC, existing ones can be edited and then provided for export to the REA ScanCheck 3n.
- Version of decoder and evaluation software (1.0.10.14 in this - case) Serial number of the REA ScanCheck 3n (003.207.106-04015-7 in this case) The assigned name (SC3_PoE in this case) stands under unit name. The assigned user name (SC_3 User in this case) These specifications serve as information on the software versions operated with the unit and are always required when technical support is requested.
Streamlining • Development • Automation Elektronik Electronic Devices and Systems GmbH Appendix Technical Data - REA ScanCheck 3n Charger voltage supply via supplied power-over-Ethernet Input: DC 48 V / 0.5 A operation, 0.32 A max. charge current Battery operation 4 x 1.2 V / 2,500 mAH NiMH batteries, rechargeable...
Elektronik Electronic Devices and Systems GmbH Appendix Technical Data - PoE Power Supply / Charger for REA ScanCheck 3n Input voltage 100 –240 Volt AC / 50 – 60 Hz, 0.32 A ~ Connection via 3-pole cold unit plug socket and network connection line with grounding plug.
"REA_Verifier“, Password: "REA-C36754“. Protected Trademarks All of the product names that are known to REA to be protected were correspondingly marked with the following symbol in this document. Microsoft®, Embedded Visual Tools®, are registered trademarks of the Microsoft Corporation in the USA and other countries;...
Express deliveries can be made upon request. The additional cost incurred for this will always be charged. If the unit is not sent to REA in the original packaging, REA will use new original packaging for the return shipment and this will be charged.
Streamlining • Development • Automation Elektronik Electronic Devices and Systems GmbH Appendix - CE Conformity Statement for REA ScanCheck 3 EG - Konformitätserklärung Declaration of conformity Déclaration de conformité Das Unternehmen / The company / La société REA Elektronik GmbH Teichwiesenstraße 1...
• conformance specification – Part 1 Linear symbols The REA ScanCheck 3n is a unit that fulfills the minimum functionality (mandatory) and the optional functions (optional) of this standard. ENV 12647 Bar coding - verification requirements for bar code verification units •...
It should be replaced no later than 2 years after delivery by a new original calibration card. Verification Tool Monitoring The REA ScanCheck 3n must be inspected in connection with a verification tool monitoring regularly every 4 to 8 weeks. This should be done using the reference code on this calibration card, directly after a calibration and in reference and comparison to the enclosed reference verification report.
Need help?
Do you have a question about the ScanCheck 3n and is the answer not in the manual?
Questions and answers
When I try do calibrate my REA Scancheck 3 I get the error code: "Error during adjustment [0x40081009] What should I do?