Displays - Extraflame LUISELLA User Manual

Table of Contents

Advertisement

Display
off
Generator off
sTaRT
The start-up phase is in progress
pelleT loaDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is working at minimum
final cleaninG
The final cleaning is in progress
sTanD-by
Generator off waiting for re-ignition due to the external thermostat.
A new ignition is attempted when the generator has just been switched off. When the generator switches off, you must
coolinG sTanD by
wait for the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when
these operations have been performed.
black ouT sTanD
The generator is cooling after a power cut.
by
Once cooling is completed, it will re-start automatically
auTo bloW
The automatic blow is active
When this message appears, contact the technician authorised to perform routine maintenance on the stove. If the
seRvice
cleaning is not performed, the message will appear at every start-up but without interrupting the normal operation of
the stove.
Display
Indicates the presence of an alarm.
e00
Fumes motor fault
e01
Fumes probe fault.
e02
High fumes temperature
NO IGNITION
The pellet hopper is empty.
e03
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
NO FLAME
The pellet hopper is empty.
e04
No pellet feed.
The gearmotor does not feed pellets.
DEPR ALARM
The door is not closed correctly.
e05
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty.
NO IGNITION BLACK OUT
e06
No current during the ignition phase.
Triac
e07
Abnormal pellet loading.

Displays

alaRMs
eXplanaTion
ENGLISH
Reason
soluTion
On: indicates the presence of an alarm.
The alarm can only be reset if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
Contact after-sales centre
Contact after-sales centre
Check pellet feed (see "Easy"), if the problem cannot be solved, contact
an authorised technician.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see "Easy").
Check the procedures described in the "Ignition" chapter.
Check the thermostats with bulbs (see chapter on Resetting)
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see "Easy").
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Turn the stove off using key 1 and repeat the procedure described in
the "Ignition" chapter.
Other reset operations should be performed by an authorised
technician.