Page 2
AIR CARE SEMINAR TRAINING Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance, and servicing of Sullair products. Individual seminars on Stationary compressors and compressor electrical systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility located at Michigan City, Indiana.
Page 3
ENTRAPMENT 1.11 SAFETY WARNINGS SECTION 2—DESCRIPTION INTRODUCTION DESCRIPTION OF COMPONENTS SULLAIR COMPRESSOR UNIT, FUNCTIONAL DESCRIPTION COMPRESSOR COOLING AND LUBRICATION SYSTEM, FUNCTION- AL DESCRIPTION COMPRESSOR DISCHARGE SYSTEM, FUNCTIONAL DESCRIPTION CONTROL SYSTEM, FUNCTIONAL DESCRIPTION AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION INTEGRAL DRYER OPTION VARIABLE SPEED DRIVE (VSD) COMPONENTS 2.10...
Page 4
TABLE OF CONTENTS AIR-COOLED, IDENTIFICATION 40HP AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 25-30HP AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 40HP PIPING AND INSTRUMENTATION, AIR-COOLED 3.10 PIPING AND INSTRUMENTATION, 1800-2200 W/INTEGRAL DRYER 3.11 WIRING DIAGRAM—MFV, AIR-COOLED 3.12 WIRING DIAGRAM—MFV, AIR-COOLED INTEGRAL DRYER 3.13 WIRING DIAGRAM—VSD, PARALLEL WYE SVX9000 3.14...
GENERAL tions relative to personal protective equipment, such as eye and face protective equipment, Sullair and its subsidiaries design and manufacture respiratory protective equipment, equipment all of their products so they can be operated safely. intended to protect the extremities, protective...
SECTION 1 inside diameter to reduce pressure in case of accumulate on, under or around acoustical mate- hose failure. rial, or on any external surfaces of the air com- pressor. Wipe down using an aqueous industrial D. Flow-limiting valves are listed by pipe size and cleaner or steam clean as required.
SECTION 1 C. Wear snug-fitting clothing and confine long hair when working around this compressor, especially DANGER when exposed to hot or moving parts. D. Keep access doors, if any, closed except when making repairs or adjustments. E. Make sure all personnel are out of and/or clear of the compressor prior to attempting to start or operate it.
SECTION 1 swallowed, induce vomiting by administering a tablespoon of salt, in each glass of clean, warm water until vomit is clear, then administer two teaspoons of baking soda in a glass of clean DANGER water. Have patient lay down and cover eyes to exclude light.
SECTION 1 Keep lift operator in constant attendance when- operation. ever compressor is suspended. J. Set compressor down only on a level surface WARNING capable of safely supporting at least its weight and its loading unit. Ground the unit following the instructions in this K.
Page 10
Code, and/or any other applicable State, speed drive during motor or cable testing. Federal, and local electrical codes concern- ing isolation switches, fused disconnects, etc. Sullair provides a wiring diagram for use CAUTION by the installer. Do not touch any components on the circuit NOTE boards.
The complete package includes compressor, electric motor, starter, compressor inlet system, compressor Compared to other types of compressors, the Sullair discharge system, compressor lubrication rotary screw is unique in mechanical reliability, with cooling system, capacity control system, WS “no wear”...
7. WS Controller 14. Variable Speed Drive (where equipped) SULLAIR COMPRESSOR NOTE UNIT, FUNCTIONAL DESCRIPTION With a Sullair compressor, there is no maintenance or inspection of the internal Sullair compressors feature Sullair parts of the compressor unit permitted in compressor...
SECTION 2 1800-3000 USER MANUAL The 1800, 2200 & 3000 Series compressors are from the air. At this time, the air flows factory-filled with Sullube lubricant. For more through an aftercooler and separator then to information on fluid fill, refer to Section 3: Lubrication your service line while the fluid is being Change Recommendations and Maintenance—Fluid...
Page 14
1800-3000 USER MANUAL SECTION 2 Figure 2-2: Cooling and Lubrication System...
Page 15
SECTION 2 1800-3000 USER MANUAL COMPRESSOR DISCHARGE minimum pressure/check valve, located SYSTEM, FUNCTIONAL downstream from the separator, assures a minimum DESCRIPTION separator/sump tank pressure of 50 psig (3.4 bar) during loaded conditions. This pressure is necessary Refer to Figure 2-3. The compressor unit discharges...
SECTION 2 1800-3000 USER MANUAL CONTROL SYSTEM, Start Mode FUNCTIONAL DESCRIPTION —0 TO 50 PSIG (0 TO 3.5 Bar) When the compressor “ ” (START) pad is Refer to Figure 2-4. The purpose of the compressor depressed, the separator/sump tank pressure will control system is to regulate the amount of air being quickly rise from 0 to 50 psig (0 - 3.4 bar).
Page 18
1800-3000 USER MANUAL SECTION 2 Full Load Mode check valve in the air service line prevents line —50 to 100 PSIG (3.4 to 6.9 BAR) pressure from returning to the separator/sump tank. When the compressed air pressure rises above 50 When the line pressure drops to the low setting (cut- psig (3.4 bar), the minimum pressure valve opens...
For other settings and control options, refer locations, e.g. in exposed plant piping.” (I) to the WS controller manual 02250165-411, or to your authorized Sullair servicing distributor. Sullube should not be used with PVC piping In case the compressor needs to operate while the systems.
Page 24
Speed—25, 30 HP: 1765 RPM (60 Hz) or 1475 RPM (50 Hz) (IV) Multi-frequency and voltage motors are used. The compressors msust be used only with the specified electrical frequency and voltage. NOTE For latest sound test data, consult Sullair factory.
Refer to Figure 3-1 for location of fluid fill port. For plugging, orifice or line plugging. best value and longest uninterrupted service, the 1800, 2200 & 3000 Series compressors are factory filled and tested with Sullube lubricant. NOTE Flush system when switching lubricant CAUTION brands.
1800-3000 USER MANUAL SECTION 3 APPLICATION GUIDE Sullair encourages the user to participate in a fluid analysis program with the fluid suppliers. This could result in a fluid change interval differing from that stated in the manual. Contact your Sullair dealer for details.
Page 29
AIR-COOLED, IDENTIFICATION 25-30HP Main Motor HP Motor Type Weight CFM Cooling Air 1374 LBS/623 KG 2000 CFM TEFC 1420 LBS/644 KG 2000 CFM 1383 LBS/627 KG 2000 CFM TEFC 1450 LBS/658 KG 2000 CFM NOTES: A1: SPACE REQUIRED TO OPEN DOORS 1.
Page 31
AIR-COOLED, IDENTIFICATION 40HP Main Motor HP Motor Type Weight CFM Cooling Air 1556 LBS/706 KG 2900 CFM TEFC 1613 LBS/732 KG 2900 CFM NOTES: A1: SPACE REQUIRED TO OPEN DOORS 1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE A2: SPACE REQUIRED TO OPEN STARTER PANEL AROUND MACHINE FOR ACCESS AND FREE CIRCULA- A3: CONTROLLER TION OF AIR.
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 25-30HP 02250168-699-R03...
Page 33
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 25-30H Main Motor HP Motor Type Weight CFM Cooling Air 1575 LBS/714 KG 2000 CFM TEFC 1621 LBS/735 KG 2000 CFM 1584 LBS/718 KG 2000 CFM TEFC 1651 LBS/749 KG 2000 CFM NOTES: A1: SPACE REQUIRED TO OPEN DOORS 1.
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 40HP 02250180-784 R01...
Page 35
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 40HP Main Motor HP Motor Type Weight CFM Cooling Air 1757 LBS/797 KG 2900 CFM TEFC 1814 LBS/823 KG 2900 CFM NOTES: A1: SPACE REQUIRED TO OPEN DOORS 1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE A2: SPACE REQUIRED TO OPEN STARTER PANEL AROUND MACHINE FOR ACCESS AND FREE CIRCULA- A3: CONTROLLER...
3.10 PIPING AND INSTRUMENTATION, 1800-2200 W/INTEGRAL DRYER 02250172-798-R02...
Page 39
3.10 PIPING AND INSTRUMENTATION, 1800-2200 W/INTEGRAL DRYER PART NO. DESCRIPTION PART NO. DESCRIPTION 02250125-369 FILTER, AIR 8”(PLASTIC) W/MTG BAND 02250168-837 VENT,ENCL PROT 1/2” TOP VALVE, GROUP INLET DXX102E 02250169-612 GA,DIFF PRESS Z-PRG ASY BTM MTR_VAR MOTOR INTEGRAL REFRIGERANT DRYER COMPRESSOR...
3.13 WIRING DIAGRAM—VSD, PARALLEL WYE SVX9000 E-STOP DISPLAY YELLOW GREEN YELLOW OPTIONAL BROWN GREEN PINK GRAY BROWN WHITE PINK ETHERNET GRAY WHITE SEE CONNECTION TABLE FOR PROPER VOLTAGE CONNECTION GREEN COLD WEATHER OPTIONS BROWN PINK GRAY WHITE TO MATCH TERMINALS ON NEXT COMPRESSOR TO CUSTOMER 120VAC SUPPLY MODULE...
Page 45
3.13 WIRING DIAGRAM—VSD, PARALLEL WYE SVX9000 COMP DESCRIPTION COMP DESCRIPTION COMPRESSOR MOTOR NOTES: COOLER FAN MOTOR STARTER DELTA 1 CUSTOMER TO FURNISH FUSED 2MOL FAN MOTOR OVERLOAD OR CIRCUIT BREAKER DISCONNECT FAN MOTOR BRANCH CIRCUIT FUSES PER LOCAL CODES. JZL TRANSFORMER PRIMARY FUSES DELTA 2 REMOVE JUMPER FOR JZL TRANSFORMER SCONDARY FUSE AUXILLIARY E-STOP...
3.14 WIRING DIAGRAM, VSD SERIES DELTA A1000 02250199-933 r00...
Page 47
3.14 WIRING DIAGRAM, VSD SERIES DELTA A1000 NOTES: COMP DESCRIPTION COMPRESSOR MOTOR CUSTOMER TO FURNISH FUSEDOR CIRCUIT BREAKER DIS- COOLER FAN MOTOR STARTER CONNECT PER LOCAL CODES. 2MOL FAN MOTOR OVERLOAD REMOVE JUMPER FOR AUXILLIARY E-STOP STRING DEVICES. FAN MOTOR BRANCH CIRCUIT FUSES SCD TRANSFORMER PRIMARY FUSES USE ISOLATING RELAYS WITH DRY CONTACTS FOR ANY SCD TRANSFORMER SCONDARY FUSE...
1800-3000 USER MANUAL Section 4 INSTALLATION MOUNTING OF VENTILATION & COOLING COMPRESSOR Air-Cooled Compressors A suitable foundation or fabricated support must be • An area with adequate space must be pro- established to support the compressor. It should be vided for the compressor and its compo- rigid enough to keep the compressor frame level and nents.
Discharged air contains a very small 35˚F (1.7˚C) amount of compressor lubricating oil, and care should be taken to ensure that this oil would not interfere with downstream equipment. Downstream filters (available from Sullair) can remove any liquid carry- over.
Page 53
SECTION 4 1800-3000 USER MANUAL Figure 4-1: Service Air Piping, Typical Installation 1. Sullair Compressor 5. Water Leg Drain Valve 2. Sullair Dryer 6. By-Pass Gate Valve 3. Shut-Off Gate Valve 7. Standard Gate Valve 4. Sullair Filter When two compressors are operated in parallel,...
1800-3000 USER MANUAL SECTION 4 ELECTRICAL PREPARATION Interior electrical wiring is performed at the factory. Required customer wiring should be done by a CAUTION qualified electrician in compliance with OSHA, National Electrical Code, and/or any other applicable The use of plastic bowls on line filters and...
SECTION 4 1800-3000 USER MANUAL • A few electrical checks should be made to MOTOR ROTATION help assure that the first start-up will be DIRECTION CHECK trouble-free. Motor rotation check must be made at compressor startup. See Figure 4-2 and Figure 4-3. The...
Page 56
1800-3000 USER MANUAL SECTION 4 Figure 4-2: Fan motor/main motor rotational direction 50Hz 25HP/18kw, 50Hz or 60Hz 30HP/22kw Figure 4-3: Fan motor/main motor rotational direction 60Hz 25HP/18kw, 50Hz or 60Hz 40HP/30kw...
1800-3000 USER MANUAL SECTION 5 LCD DISPLAY Refer to Figure 5-6. Press the DOWN arrow " " to display additional information about the compressor. The display's normal view shows the compressor The upper line will indicate "Compressor Status" and package's discharge pressure, internal temperature, the name of the temperature, pressure, or other and the operating mode.
SECTION 5 1800-3000 USER MANUAL the normal view. The green RUN mode indicator " " indicates compressor operation is enabled. It lights steadily if The list of displays may be navigated from either the motor is running. If the motor stops while in direction by using the UP "...
1800-3000 USER MANUAL Section 6 MAINTENANCE GENERAL WARNING WARNING HIGH-PRESSURE HAZARD! • DO NOT remove caps, plugs, and/or other Before any repairs are attempted, refer to components when compressor is running Section 1: Safety before proceeding. or pressurized. Stop compressor and relieve all internal pressure before doing so.
1800-3000 USER MANUAL SECTION 6 2. Replace the fluid filter element. 1. As indicated by the WS Controller. 3. Pull oil sample for analysis 2. Every fluid change. 4. Check air filter. Change if necessary. Refer to Figure 6-1. Fluid Filter Element Replacement Refer to Figure 6-1.
SECTION 6 1800-3000 USER MANUAL Air Filter Element Replacement 7. Replace the cover plate, washers and cap screws. Torque to 70 ft·lbs (95 N·m). 1. Clean exterior of air filter housing. 8. Clean the return line strainer before restart- 2. Rotate end cover counterclockwise and ing the compressor.
Page 64
1800-3000 USER MANUAL SECTION 6 Troubleshooting— Introduction on page 65. The 4. Inspect and clean the orifice inside the sight glass blocks. The orifice must be removed maintenance on a fluid return/sight glass is mainly with an allen wrench. concerned with the condition of the filter assembly.
4. Install the new element by wrapping it around the jaws, engaging the cogs on the Should your problem persist after making the element into the jaws. recommended check, consult your nearest Sullair representative. SYMPTOM PROBABLY CAUSE REMEDY...
Page 66
1800-3000 USER MANUAL SECTION 6 SYMPTOM PROBABLY CAUSE REMEDY Compressor Shuts Down With Air Loss of Control Voltage Reset. If trouble persists, check that line Demand Present pressure does not exceed maximum oper- ating pressure of the compressor (specified on nameplate).
Page 67
SECTION 6 1800-3000 USER MANUAL SYMPTOM PROBABLY CAUSE REMEDY Line Pressure Rises Above Unload Leak In Control System Causing Check for leaks. Pressure Set-Point Loss of Pressure Signals Inlet Valve Stuck Open Remove the intake hose and check for inlet valve operation.
Page 70
Always air. Always there. WWW.SULLAIR.COM SULLAIR 3700 East Michigan Boulevard • Michigan City, Indiana, 46360 U.S.A. Telephone: 1-219-879-5451 Printed in the U.S.A. Specifications subject to change without prior notice. E14EP...