Virtual Outputs - GE B30 Instruction Manual

Bus differential system
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
: "VO1"
OUTPUT H1a OPERATE
: "VO2"
OUTPUT H1a RESET

5.9.4 Virtual outputs

SETTINGS  INPUTS/OUTPUTS  VIRTUAL OUTPUTS  VIRTUAL OUTPUT 1(96)
 VIRTUAL OUTPUT 1
The virtual inputs and outputs are digital signals associated with UR-series internal logic signals. Virtual inputs include
signals generated by the local user interface. The virtual outputs are outputs of FlexLogic equations used to customize the
device. Virtual outputs can also serve as virtual inputs to FlexLogic equations.
There are 96 virtual outputs that can be assigned using FlexLogic. If not assigned, the output is forced to 'OFF' (Logic 0). An
ID also can be assigned to each virtual output. Virtual outputs are resolved in each pass through the evaluation of the
FlexLogic equations. Any change of state of a virtual output can be logged as an event if programmed to do so.
For example, if Virtual Output 1 is the trip signal from FlexLogic and the trip relay is used to signal events, the settings is
programmed as follows:
: "Trip"
VIRTUAL OUTPUT 1 ID
VIRTUAL OUTPUT 1 EVENTS
5.9.5 Resetting
5.9.5.1 Enhanced and standard front panels
SETTINGS  INPUTS/OUTPUTS  RESETTING
 RESETTING
5.9.5.2 Graphical front panel
SETTINGS  INPUTS/OUTPUTS  RESETTING
 RESETTING
Some events can be programmed to latch the front panel LED event indicators, target messages, and/or graphical front
panel annunciator windows. Once set, the latching mechanism holds the latched indicators, messages, or windows in the
set state after the initiating condition has cleared until a
FlexLogic latches) to the reset state where the initiating condition has cleared. The
front panel RESET button, a remote device via a communications channel, or any selected operand. The Modbus execute
function 05h with operation code 1 command is also available to perform the same function as the front panel RESET key.
— The three sources of
RESET OPERAND
source of a
command also activates its individual operand
RESET
identify the source of the command. Each of these three operands generates an event in the event record when activated.
The
setting here selects the operand that activates the
RESET OPERAND
— Used to select a FlexLogic operand that when activated acknowledges/resets all annunciator
RESET ANNUNCIATOR
windows on the graphical front panel. The other methods to acknowledge/reset annunciator windows include:
On the displayed page, press the RESET pushbutton with none of the annunciator windows selected to acknowledge/
reset all annunciator windows on that page
B30 BUS DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
VIRTUAL OUTPUT 1 ID
Virt Op 1
VIRTUAL OUTPUT 1
EVENTS: Disabled
: "Disabled"
RESET OPERAND:
Off
RESET OPERAND:
Off
RESET ANNUNCIATOR:
Off
RESET
commands each activates the
RESET
Range: up to 20 alphanumeric characters
Range: Disabled, Enabled
Range: FlexLogic operand
Range: FlexLogic operand
Range: FlexLogic operand
command is received to return these latches (not including
command can be sent from the
RESET
FlexLogic operand. Each individual
RESET OP
,
RESET OP (PUSHBUTTON)
RESET OP (COMMS)
operand.
RESET OP (OPERAND)
INPUTS/OUTPUTS
, or
to
RESET OP (OPERAND)
5-263
5

Advertisement

Table of Contents
loading

Table of Contents