Demo Mode - Haier HRF-521DS6 Service Manual

Hide thumbs Also See for HRF-521DS6:
Table of Contents

Advertisement

SERVICE MANUAL
Model: HRF-521DS6
Fault code is not displayed directly; after repair personnel operate the compound key, the fault code
can display.
Notes: in the eight section character display mode, A、 B、 C、 D、 E、 F、 R、 T、 H display respectively
according to the following type:
8-3.Self-testing function
(1).Force start: Under locked mode, Press and hold "Refrigerator"button and click "Power Freeze" button for
five times within 3 sec. then press "unlock" button,and the REF and FRZ display icon will display (T1,T1)
(2).Forced defrost :Keep the current state ,and press"unlock" button ,T2 will be present, then enter forced
defrost mode.
(3).Quit:
Keep the current state, press "unlock" button ,then will be present T3→T4→back to normal display
control,and escape from test mode.
MODE
WORKING CONDITION
1)R and F display areas:T1、T1;
2)Compressor start work;
3)Freezer FAN work with high votage;
Force start
Cooling FAN work with high votage;
4)defrost heater off;
5)REF air damper open;
1)R and F display areas:T2、T2;
2)Enter defrost mode:
compressor OFF
Freezer /Cooloing FAN OFF
Forced
Defrost heater work,
defrost
if the D-SNR ≥ 7℃,D HTR work 10 sec and then quit test 2 mode;
if the D-SNR<7℃,D HTR will keep working until the D-SNR ≥ 7℃, and then quit test 2 mode;
3)REF air damper keep close
Keep the current state, press "Set" ,then will be present T3→T4→back
Quit
to normal display control,and escape from test mode.

8-4.Demo mode

(1) Under the LOCK state;
(2)
Press and hold the " Refrigerating temperature adjustment button"
(3) Press the" quick- cooling adjustment button" 5 times(interval 0.5~0.8 seconds).
Issue 2016-09-07
Ref 1609S025V0
.
REF.
23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HRF-521DS6 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF