4. PARAMETER TABLE and factory default settings

IMPORTANT: Always set parameter "tC" first. As you move "tC" between settings 1 to 7, all non-relevant parameters will be masked. After setting
"tC", it will be possible to modify all the other relevant parameters.
Once the program is completed you may want to save the parameter map to a Hot Key. If the "tC" is changed after final programming the
parameters will be changed back to the default listed below.
WARNING!!
Always switch the power OFF and then ON at the end of programming to update any parameter changes.
Make sure you connect the correct number of probes to suit the setting of parameter tC. Failure to do this will cause probe alarms
tC setting
No. Probes
1, 2
3, 4, 5, 6
7
Any probe alarms can be cleared by turning off / on the power
Table 3: default controller parameters
Description
Type (category) of controller
Set Point
Probe type
Differential
Minimum Set Point limit
Maximum Set Point limit
Anti-short cycle delay
Second compressor start delay
Temperature alarm configuration
High temperature alarm
Low temperature alarm
Temperature alarm delay
Delay of temperature alarm at start up
Outputs activation delay at start up
Thermostat override
Set point for continuous cycle
Defrost delay after thermostat override
Interval between defrosts
Delay start of defrost
Maximum duration of defrost
Defrost termination temperature
Universal-XR
Installation and Operating Instructions
Type
1
Room only
2
Room + Evaporator 1
3
Room + Evaporator 1 + Display or AUX
Label
Adjustment Range
1 = On / Off Thermostat
2 = Off cycle defrost
3 = Time / time defrost
TC
4 = Time / temp defrost + alarm
5 = Time / temp defrost
6 = Time / temp defrost + fan delay
7 = Full Open Map Configurable
SET
LS to US
PBC
PTC=0
NTC=1
HY
0.1 to 25.5C;
1 to 45°F
LS
-55C to Set Point;
-67°F to Set Point
US
Set Point to 150C;
Set Point to 302°F
AC
0 to 50 min
AC1
0 to 255 sec.
ALC
rE (0) = Relative to Set Point;
Ab (1) = Absolute
ALU
0 to 50C (Rel); ALL to 150C (Abs);
0 to 90F (Rel); ALL to 302C (Abs)
ALL
0 to 50C (Rel); -55C to ALU (Abs);
0 to 90C (Rel); -67C to ALU (Abs)
ALD
0 to 255 min
DAO
0 to 720 min
ODS
0 to 255 min
CCT
0 to 990 min
CCS
-55 to 150°C;
-67 to 302°F
DAF
0 to 255 min
IDF
1 to 250 hours
DSD
0 to 255 min
NDF
0 to 255 min
DTE
-55 to 50C;
-67 to 122°F
tC1
tC2
tC3
1
2
3
40.0°C;
2.0°C;
2.0°C;
104°F
36°F
36°F
1
1
1
2.0°C;
2.0°C;
2.0°C;
10°F
4°F
4°F
-50.0°C;
-50.0°C;
-50.0°C;
-58°F
-58°F
-58°F
50.0°C;
50.0°C;
50.0°C;
122°F
122°F
122°F
1
1
1
1
1
1
50.0°C;
50.0°C;
50.0°C;
122°F
122°F
122°F
-50.0°C;
-50.0°C;
-50.0°C;
-58°F
-58°F
-58°F
15
15
15
90
90
90
0
0
0
0
0
2.0°C;
2.0°C;
36°F
36°F
2
2
4
6
0
0
15
15
8.0°C
46°F
3/17
tC4
tC5
tC6
tC7
4
5
6
7
2.0°C;
2.0°C;
2.0°C;
2.0°C;
36°F
36°F
36°F
36°F
1
1
1
1
2.0°C;
2.0°C;
2.0°C;
2.0°C;
4°F
4°F
4°F
4°F
-50.0°C;
-50.0°C;
-50.0°C;
-50.0°C;
-58°F
-58°F
-58°F
-58°F
50.0°C;
50.0°C;
50.0°C;
50.0°C;
122°F
122°F
122°F
122°F
1
1
1
0
0
1
1
1
1
50.0°C;
50.0°C;
50.0°C;
50.0°C;
122°F
122°F
122°F
122°F
-50.0°C;
-50.0°C;
-50.0°C;
-50.0°C;
-58°F
-58°F
-58°F
-58°F
15
15
15
15
90
90
90
90
0
0
0
0
0
0
0
0
2.0°C;
2.0°C;
2.0°C;
2.0°C;
36°F
36°F
36°F
36°F
2
2
2
2
6
6
4
4
0
0
0
0
30
30
30
30
8.0°C
8.0°C
8.0°C
8.0°C
46°F
46°F
46°F
46°F
UXR01212015_REV1.4mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNIVERSAL XR60CX and is the answer not in the manual?

Questions and answers

Jimmy hall
April 24, 2025

The evap fan icon will not come on and no fan

Table of Contents

Save PDF