Table of Contents

Advertisement

Quick Links

RFD01F Series
Installation Manual
Describes product installation and requirement procedure.
Document Version 1.0
January 2017
Document Number: -

Advertisement

Table of Contents
loading

Summary of Contents for Samsung RFD01F series

  • Page 1 RFD01F Series Installation Manual Describes product installation and requirement procedure. Document Version 1.0 January 2017 Document Number: -...
  • Page 2 SAMSUNG Electronics Co., Ltd., its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document. SAMSUNG Electronics Co., Ltd. reserves the right to change details in this publication without notice. SNMTC-v3-0312 This manual should be read and used as a guideline for properly installing and/or operating the product.
  • Page 3: Table Of Contents

    Cabling Diagram ..........................43 Grounding ............................45 Ground Cable Connection ......................46 Power Cabling ..........................48 Power Cable Connection ......................49 Interface Cable Connection ......................59 Optic Module Remove/Insert ....................59 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 4 Inspect the Installation Appendix A Acronyms Appendix B Clean the Optical Connectors Introduction ........................... 92 Measure the Optical Output and Connecting the Optical Connector ........93 Appendix C Standard Torque RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 5 Power Connector Assembly (8) ...................... 54 Figure 44. Power Connector Assembly (9) ...................... 55 Figure 45. Power Connector Assembly (10) ....................55 Figure 46. Hybrid(Power) Cable Connection (1) ..................... 57 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 6 RF Cable Connection using a Cold Shrink Tube (4) ................. 82 Figure 77. RF Cable Connection using a Cold Shrink Tube (5) ................. 83 Figure 78. Installation Inspection Procedure ....................86 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 7 Construction Situation Check list ....................87 Table 30. Standard Torque Value for Fastening Bolts ................... 94 Table 31. Brass Bolts Torque Value........................ 94 Table 32. Connector Connection Torque Value ..................... 94 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 8: Preface

    Preface This manual describes how to install the 850MHz RRU including how to connect cables. This manual includes the following 850MHz RRU(SLS-BR03U): Conventions in this Document Samsung Networks product documentation uses the following conventions. Symbols Symbol Description Indicates a task.
  • Page 9: New And Changed Information

    All structural parts are grounded and all input and outputs have built-in isolation from the network. All input and output ports that connect to external power sources are designed to meet relevant national safety requirements. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 10 Always connect the ground cable before fitting other cables. The product must remain grounded continuously unless all connections to the power supply and data network are all removed. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 11 This Perchlorate warning applies only to primary CR (Manganese Dioxide) Lithium coin cells in the product sold or distributed ONLY in California USA ‘Perchlorate Material-special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate.’ RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 12: Chapter 1 Before Installation

    System Configuration and Interface RRU Configuration The configuration of RRU is as follows: Figure 1. RRU Configuration Unit: in.(mm) [Top View] 12.59 (320) [Left View] [Front View] [Right View] [Rear View] [Bottom View] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 13: Rru Interface

    Chapter 1 Before Installation RRU Interface The interface structure of RRU is as follows: Figure 2. RRU Interface ANT0 ANT1 ANT2 ANT3 Ground Terminal DC_PWR L0 (CPRI_0) L1 (CPRI_1) [Bottom View] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 14: Specifications

    Cautions for Installation Observe the following safety instructions when installing the system: Installation shall be in accordance with the applicable local electric codes. The equipment shall be located in restricted access locations. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 15: Before Installing

    Use the hole finishing materials including dust cap and rubber packing. - Cable-installed inlet After cable installation, block any space in the inlet with tape, compressed sponge, rubber packing, and silicon. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 16: After Installing

    Adjustable Torque Wrench Apply a torque range For fastening Optic Cable Adapter : 10~50 lbf.in.(30~150 kgf·cm) Torque Wrench Spanner Head Hexagon Head: 0.39 in.(10 mm) For fastening M6 Hex. Bolt RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 17 Concrete Drill Bit 0.55 in.(14 mm) For M10 Set Anchor Bolt Anchor Punch For M10 Set Anchor Bolt Hammer Normal Anchor fixing Vacuum Cleaner Normal For removing dust during the drilling work RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 18 Angle Meter Normal Antenna angle measurement Multi master(VSWR & RF Normal Feeder VSWR measurement Power) Fiber Optic Test Set Wave length: Optical level check 1270 nm, 1310 nm, 1550 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 19 The required installation tools may vary depending on the conditions at the site. In addition to the basic tools, a protractor, GPS receiver, ladder, safety equipment, cleaning tools, and so on should also be prepared in consideration of the site conditions. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 20: Chapter 2 Installing System

    Installing the system with the power switch ON may cause system damage or fatal human injury when connecting or disconnecting the cables. To prevent the risk of electrical shock do not wear accessories such as watches and rings. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 21: System Arrangement

    A minimum distance must be secured around the RRU, in each direction for installation and maintenance. Figure 4. RRU_Wall Type Standard Installation Unit: in.(mm) Wall ≥12(300) ≥12(300) ≥8(200) ≥16(400) 12.59 (320) [Front View] Wall ≥32(800) [Top View] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 22: Figure 5. Rru Arrangement_Pole Type Installation

    (Φ 3~4.5 (76.3~114.3)) Pole [Top View] ≥32 (800) [Side Installation] 7.68 (195) Pole ≥12 (300) [Side View] ≥8 (200) ≥8 (200) Front Front ≥12 (300) Pole (Φ 3~4.5 (76.3~114.3)) Pole ≥32 (800) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 23: Unpacking And Transporting

    Unpack only external packing, leaving the internal packing in unpacked status.  Unpack the inner packaging after each system is placed on its installation location.  Scrap by-products (packaging waste) in accordance with the rule. Do not recycle the by-products. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 24: Rru Handling

    When transporting an RRU, hold a handle at the top of the RRU. (No tool is needed for using the handle.) Figure 6. Using a Handle to transport an RRU Handle RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 25: Fixing Rru

    RRU (Side installation). These are the same for the wall type and pole type installation procedures. Figure 7. Unit Bracket Fixing Type Unit Bracket [Unit Bracket Standard Installation] [Unit Bracket Side Installation] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 26: Figure 8. Unit Bracket Fixing (Standard Installation)

    Screw Driver(+, No.2) Place a unit bracket to the RRU rear and fix it using fasteners. Standard Installation) Figure 8. Unit Bracket Fixing ( Unit Bracket M6 Hex. Bolt(WSP) M6 Hex. Bolt(WSP) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 27: Figure 9. Unit Bracket Fixing (Side Installation)

    Screw Driver(+, No.2) Place a unit bracket to the RRU side and fix it using fasteners. Side Installation Figure 9. Unit Bracket Fixing ( Unit Bracket M6 Hex. Bolt(WSP) M6 Hex. Bolt(WSP) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 28: Fixing Pole Type

    When fixing the pole mounting bracket, the specification of carriage bolt is M10 × 220L for the pole diameter from 3in. (76.3mm) to 4.5in. (114.3mm). Insert carriage bolts to the Mounting bracket_front. Figure 10. Assembling the Mounting Bracket_Pole Type(1) Mounting Bracket_Front M10 Carriage Bolt RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 29: Figure 11. Assembling The Mounting Bracket_Pole Type(2)

    Figure 11. Assembling the Mounting Bracket_Pole Type(2) M10 Hex. Nut M10 Spring Washer M10 Plain Washer Mounting Bracket _Rear M10 Carriage Bolt Mounting Bracket _Front Mounting Bracket _Rear Side open hole RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 30: Figure 12. Lifting Rru & Pole Mounting Bracket Assembly_Pole Type(1)

    Tie the rope in two carrying points Figure 12. Lifting RRU & Pole Mounting Bracket Assembly_Pole Type(1) Carrying Point_1 Carrying Point_2 [RRU] Carrying Point_1 Carrying Point_2 [Pole Mounting Bracket Assembly] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 31: Figure 13. Lifting Rru/Pole Mounting Bracket Assembly_Pole Type(2)

    Operator B pulls the rope outward so that RRU/pole mounting bracket assembly would not hit the tower platform Figure 13. Lifting RRU/Pole Mounting Bracket Assembly_Pole Type(2) Pulley RRU, Pole Mounting Bracket Assembly Tower Platform Rope Operator A Operator B RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 32: Figure 14. Assembling The Mounting Bracket Assembly_Pole Type(1)

    Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 0.66 in.(17 mm)) Spanner (Hexagon Head: 0.66 in.(17 mm)) Place the pole mounting bracket assembly on a pole. Figure 14. Assembling the Mounting Bracket Assembly_Pole Type(1) Pole(45~115mm) Pole Mounting Bracket Assembly RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 33: Figure 15. Assembling The Mounting Bracket Assembly_Pole Type(2)

    When fixing the pole mounting bracket assembly on a pole, be sure to check the level of bracket. After finishing the installation, you can adjust the level minutely. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 34: Figure 16. Leveling Pole Mounting Bracket Assembly

    Chapter 2 Installing System Figure 16. Leveling Pole Mounting Bracket Assembly [Measuring horizontal position] [Measuring vertical position] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 35: Figure 17. Rru Fixging_Pole Type (Standard Installation)

    Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 0.66 in.(17 mm)) Hang the unit bracket_hook of of RRU rear on the mounting bracket_front hook’s groove. Figure 17. RRU Fixging_Pole Type (Standard Installation) Unit Bracket_Hook Mounting Bracket_Front Hook Groove RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 36: Figure 18. Rru Fixing_Pole Type (Standard Installation)

    Chapter 2 Installing System Fix the RRU using fasteners. Figure 18. RRU Fixing_Pole Type (Standard Installation) M10 Hex. Bolt (WSP) Unit Bracket RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 37: Figure 19. Rru Fixing_Pole Type (Side Installation)

    Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 0.66 in.(17 mm)) Hang the unit bracket_hook of RRU side on the mounting bracket_front hook’s groove. Figure 19. RRU Fixing_Pole Type (Side Installation) Unit Bracket_Hook Mounting Bracket_Front Hook Groove RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 38: Figure 20. Rru Fixing_Pole Type (Side Installation)

    Chapter 2 Installing System Fix the RRU using fasteners. Figure 20. RRU Fixing_Pole Type (Side Installation) M10 Hex. Bolt (WSP) Unit Bracket RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 39: Fixing Wall Type

    When the position where the system will be placed is determined, place the system on that position and then mark the positions where anchor bolts will be fixed. This will reduce marking error range. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 40: Figure 21. Rru Dimensions For Wall Type (Standard Installation)

    5.12(130) 3.74(95) M10 Anchor Bolt Hole [Rear View] Figure 22. RRU dimensions for Wall Type (Side Installation_ Anchor Bolt Hole Unit: in.(mm) 7.68(195) 5.12(130) M10 Anchor Bolt Hole [Rear View] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 41: Figure 23. Example Of Marking_Use The Mounting Bracket

    Marking Point If it is level, the bubble of the spirit level is positioned at the center of both lines. 130mm Drill anchor holes at the marked locations on a wall. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 42: Figure 24. Drilling & Anchoring Example

    Drill anchor holes at marked points with removing dust from the holes using a cleaner. Figure 24. Drilling & Anchoring Example Vacuum Cleaner M10 Anchor Bolt Hammer Drill Anchor Punch Hammer 0.55 in. (14 mm) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 43: Figure 25. Fixing Mounting Bracket On A Wall

    Place the mounting bracket_front along with the fixed strong anchors. Fix the mounting bracket_front using fasteners. Figure 25. Fixing Mounting Bracket on a Wall Mounting Bracket_Front M10 Plain Washer M10 Spring Washer M10 Hex. Bolt RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 44 When fixing the mounting bracket_front on a wall, the clearances between the wall and left (A)/right (B) sides of mounting bracket_front should be the same. Wall Mounting Bracket_Front [Top View] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 45: Figure 26. Rru Fixing_Wall Type Standard Installation(1)

    Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 0.66 in.(17 mm)) Hang the unit bracket_hook of of RRU rear on the mounting bracket_front hook’s groove. Figure 26. RRU Fixing_Wall Type Standard Installation(1) Unit Bracket_Hook Mounting Bracket_Front Hook Groove RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 46: Figure 27. Rru Fixing_Wall Type Standard Installation(2)

    Chapter 2 Installing System Fix the RRU using fasteners. Figure 27. RRU Fixing_Wall Type Standard Installation(2) M10 Hex. Bolt (WSP) Unit Bracket RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 47: Figure 28. Rru Fixing_Wall Type Side Installation(1)

    Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 0.66 in.(17 mm)) Hang the unit bracket_hook of of RRU side on the mounting bracket_front hook’s groove. Figure 28. RRU Fixing_Wall Type Side Installation(1) Unit Bracket_Hook Mounting Bracket_Front Hook Groove RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 48: Figure 29. Rru Fixing_Wall Type Side Installation(2)

    Chapter 2 Installing System Fix the RRU using fasteners. Figure 29. RRU Fixing_Wall Type Side Installation(2) M10 Hex. Bolt (WSP) Unit Bracket RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 49: Chapter 3 Connecting Cables

    The procedure to connect system cables is as follows: Figure 30. Procedure to Connect System Cable Ground Cable Connection Grounding Power Cabling Hybrid(Power) Cable Connection Hybrid(Optical) Cable Connection RET Cable Connection External Interface Connection RF Cable Connection RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 50: Guidelines For Cable Connections

    Follow these guidelines when inspecting the cabling path.  A minimum cable length must be selected provided that it does not affect the cable installation and maintenance. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 51: Cable Cutting

    If the cable needs to be protected, use for example, a PVC channel, spiral sleeve, flexible pipe, cable rack, and so on.  Install the DC power cable and data transmission cable away from the AC power cable to prevent electromagnetic induction. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 52: Cable Binding

    Make sure operator is fully aware of the connector assembly method before assembling a connector. Assemble the connector in accordance with its pin map.  Each connector has a hook to prevent its core positions from being changed. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 53: Identification Tag Attachment

    Install the DC power cable and data transmission cable away from the AC power cable to prevent electromagnetic induction. Make sure the work is done by personnel properly trained for the cabling job. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 54: Cabling Diagram

    Chapter 3 Connecting Cables Cabling Diagram The cabling diagram of the RRU is as follows: Figure 32. Cable Diagram [RF Antenna] 5) RF Cable 4) RET Cable Hybrid Cable Rectifier RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 55: Table 17. Rru Connection Cable

    The inlet hole finishing method of external equipment must be progressed after consultation with operation company in case of the cable connected to external equipment. (Optic distribution box, etc) - The Cable: Hybrid(Power) Cable, Hybrid(Optical) Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 56: Grounding

    To eliminate or minimize the high-frequency potential in the system housing  To provide a conductor for the balance and stability of high-frequency current  To stabilize the potential of the circuit against the ground RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 57: Ground Cable Connection

    Stripper(0.15~0.62 in.(4~16 mm)),Heating Gun, Nipper, Screw Driver('+', No.3) For the pressure terminal or the cable, the UL Listed products or equivalent should be used. Ex) Manufacturer-Panduit RRU: AWG8 Pressure Terminal(LCD8-14A-L) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 58: Figure 33. Ground Cable Connection (1)

    Firmly fix the pressure terminal onto the RRU ground terminal using Hex. +type. Figure 34. Ground Cable Connection (2) M6 SEMS(Hex. +) Pressure Terminal Heat Shrink Tube(Green) Ground Cable RRU Ground terminal RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 59: Power Cabling

    Install a circuit breaker to a rectifier (or power distributor) for the stable power. The capacity of circuit breaker is 20 A or 25A. (Use UL Listed circuit breakers.) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 60: Power Cable Connection

    - Back shell / Nut : 18.23 lbf.in Working Tools Cable Cutter, Wire Stripper, Nipper, Torque Driver(+, No.1), Adjustable Head:0.31~1.26 in.( 8~32mm)), Adjustable Wrench: 10~50 lbf.in., Multi Tester Coupling Nut Shell Back Shell Install Jig Screw(+) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 61: Figure 36. Power Connector Assembly (1)

    DC Power Cable Tie the cable tie at 11.81 in. (300 mm) from the end of the power cable. Figure 37. Power Connector Assembly (2) DC Power Cable Cable Tie RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 62: Figure 38. Power Connector Assembly (3)

    Be careful when striping the cable, Please don’t damage the core wire and the conductor. The color of the core wire can be changed according to the specification of the cable used. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 63: Figure 40. Power Connector Assembly (5)

    Check the color of the core wire and push it into the holes of Pin 1 and Pin 2. Figure 41. Power Connector Assembly (6) Pin 1: -48 V DC Pin 2: RTN RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 64: Figure 42. Power Connector Assembly (7)

    Figure 42. Power Connector Assembly (7) Torque Driver (+, NO.1) ※ After the screws are tightened, check if the cable is securely installed by evenly pulling the cable with a 22.45 lbf (10 kg force). RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 65: Figure 43. Power Connector Assembly (8)

    Before tightened the back shell, the cable can’t be tightened by the nut. The torque wrench used to assemble the power connector should be a product with a rubber tube on the spanner head. Rubber Tube RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 66: Figure 44. Power Connector Assembly (9)

    Figure 45. Power Connector Assembly (10) [Pin 1 & Pin 2] [Pin 1 / Pin 2 & Back Shell] After completing the assembly of the power connector, remove the cable tie from the cable. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 67: Table 20. Parts And Tools For Power Cable Connection

    Use the hole finishing materials including waterproof cap and rubber packing. - Cable-installed inlet After cable installation, block any space in the inlet with tape, compressed sponge, rubber packing and silicon. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 68: Figure 46. Hybrid(Power) Cable Connection (1)

    Fasten the nut of cable side connector by turning it clock wise until the clicking sound is not heard. Figure 46. Hybrid(Power) Cable Connection (1) White Dot Power Input Port (DC_PWR) DC Power Connector White Dot DC Power Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 69: Figure 47. Hybrid(Power) Cable Connection (2)

    Chapter 3 Connecting Cables When the nut is fastened tight, the white line on the receptacle connector should be invisible (or hidden). Figure 47. Hybrid(Power) Cable Connection (2) White Line RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 70: Interface Cable Connection

    Completely remove the optic module from the transceiver by pulling the jig. Figure 49. Optic Module Removal (2) Transceiver Optic Module Remove the optic module and the jig by pressing the jig's hook grip. Figure 50. Optic Module Removal (3) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 71: Optic Cable Connection

    Table 22. Parts and Tools for Optic Cable Adapter Assembly Category Description Parts Optic Cable Adapter Assembly 1 Set Recommended Gland Nut 17.70 lbf·in Torque Value Working Tools Adjustable Torque Wrench(10~50 lbf.in.), Adjustable Spanner (Hexagon Head: 2.04 RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 72 - Do not touch the ferrule at the end of optical cable because it is easy to be damaged. Dust Cap Ferrule [Before Removing Dust Cap] [After Removing Dust Cap] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 73: Figure 52. Optic Cable Adapter Assembly (1)

    Figure 52. Optic Cable Adapter Assembly (1) Optic Cable Adapter Assembly Gland Nut Unlock the bayonet connector. Figure 53. Optic Cable Adapter Assembly (2) Hold here when unlock bayonet Bayonet Connector RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 74: Figure 54. Optic Cable Adapter Assembly (3)

    Figure 54. Optic Cable Adapter Assembly (3) Gland SWAP Tube Hybrid Optical Cable Hybrid Optical Cable Remove the dust cap from blue and orange cable. Figure 55. Optic Cable Adapter Assembly (4) Dust Cap Dust Cap RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 75: Figure 56. Optic Cable Adapter Assembly (5)

    Get the plug with blue and orange cable to connect to adaptor corresponding color. Figure 56. Optic Cable Adapter Assembly (5) Blue Cable Adaptor Orange Cable Blue Cable Orange Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 76: Figure 57. Optic Cable Adapter Assembly (6)

    Hold here when assemble plug Bayonet connector Lock the gland nut. Figure 58. Optic Cable Adapter Assembly (7) Hold here when assemble plug Gland Nut Keep the branch cable straight RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 77: Figure 59. Optic Cable Adapter Assembly (8)

    Figure 59. Optic Cable Adapter Assembly (8) L0 Port L1 Port Waterproof Cap (System Side) Unlock the waterproof cap of Optic Cable Adapter Assembly. Figure 60. Optic Cable Adapter Assembly (9) Waterproof Cap RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 78: Figure 61. Optic Cable Adapter Assembly (10)

    Install a optic cable to the RRU L0, L1 ports. Remove the dust cap from the LC plug of CPRI cable. Figure 62. Optic Cable Adapter Assembly (11) Dust Cap Dust Cap RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 79: Figure 63. Optic Cable Connection (1)

    ‘click’ sound which confirms the latch is inserted completely. Figure 63. Optic cable connection (1) Front side LC Plug Shell LC Plug Latch should be toward the rear side of RRU. LC Plug Latch Optic Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 80: Figure 64. Optic Cable Connection (2)

    After connecting the optical cable, assemble the water proof caps at the system side and the Optic Cable Adapter side. Figure 65. Optic cable connection (3) Waterproof Cap(System side) Waterproof Cap(Optic Cable Adapter side) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 81: Figure 66. Optic Cable Connection (4)

    Fasten the waterproof cap of the optic cable adapter to the RRU_L0, L1 port using a cable tie. Figure 66. Optic cable connection (4) Cable Tie RRU Port Waterproof Cap of Optic Cable Adapter RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 82: Ret Cable Connection

    [Male: RRU Side] [Female: Antenna Side] Before fitting the RET connector, make sure to align the female connector’s hole with the male connector’s pin first. Hole [Female Connector] [Male Connector] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 83: Figure 67. Ret Cable Connection (1)

    Chapter 3 Connecting Cables Install an RET cable from the RF Antenna to the RRU RET port. Figure 67. RET Cable Connection (1) [RF Antenna] [Bottom View] RET Cable Assembly RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 84: Figure 68. Ret Cable Connection (2)

    Chapter 3 Connecting Cables Connect the RET connector to the RRU RET port. Figure 68. RET Cable Connection (2) RET Port RET Port RET Dust cap RET Connector RET Cable RET Female Port RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 85: Figure 69. Ret Cable Connection (3)

    Chapter 3 Connecting Cables Tie the RET port's dust cap to the RET connector with a cable tie. Figure 69. RET Cable Connection (3) RET Port RET Connector Cable Tie RET Dust cap RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 86: Rf Cable Connection

    (left/right side 45° each from the central axis) to prevent the antenna from lightning damage. Lightning ° ° RF Antenna As different connector types may be used depending on the RF antenna type, check the antenna connector before connecting the cable. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 87: Figure 70. Rf Cable Connection Using Jma Boots (1)

    Figure 70. RF Cable Connection using JMA Boots (1) [RF Antenna] RF Cable Assembly [Bottom View] Connect the connector assembled at the end of RRU side’s cable to the ANT_0, ANT_1, ANT_2, ANT_3 ports. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 88: Figure 71. Rf Cable Connection Using Jma Boots (2)

    Chapter 3 Connecting Cables Figure 71. RF Cable Connection using JMA Boots (2) DIN Type-Female Connector DIN Type-Male Connector JMA Boots RF Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 89: Figure 72. Rf Cable Connection Using Jma Boots (3)

    Chapter 3 Connecting Cables After connecting the connector, push JMA Boots up to the connector connection. Figure 72. RF Cable Connection using JMA Boots (3) JMA Boots RF Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 90: Table 27. Parts And Tools For Connecting Rf Cable

    DIN Type-Male (Check the RF antenna specification and prepare connecting parts.) Recommended 217 lbf·in Torque Value RF antenna 217 lbf·in Working Tools Torque Wrench(100~400 lbf·in), Spanner Head(Hexagon Head: 1.25 in.(32 mm)), Spanner(Hexagon: 1.25 in.(32 mm)) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 91: Figure 73. Rf Cable Connection Using A Cold Shrink Tube (1)

    Insert cold shrink tube to the end of RRU side’s cable. Figure 74. RF Cable Connection using a Cold Shrink Tube (2) DIN Type-Female Connector DIN Type-Male Connector Cold Shrink Tube RF Cable RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 92: Figure 75. Rf Cable Connection Using A Cold Shrink Tube (3)

    Chapter 3 Connecting Cables Connect the connector assembled at the end of RRU side’s cable to the ANT_0, ANT_1, ANT_2, ANT_3 ports. Figure 75. RF Cable Connection using a Cold Shrink Tube (3) RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 93: Figure 76. Rf Cable Connection Using A Cold Shrink Tube (4)

    Chapter 3 Connecting Cables Push cold shrink tube up to the end of RF antenna port. Figure 76. RF Cable Connection using a Cold Shrink Tube (4) Cold Shrink Tube RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 94: Figure 77. Rf Cable Connection Using A Cold Shrink Tube (5)

    Hold the cold shrink tube with one hand so that it does not move, and pull the lead wire to shrink it. Figure 77. RF Cable Connection using a Cold Shrink Tube (5) Cold Shrink Tube Lead Wire RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 95: Table 28. Rf Cable Identification Tag

    Antenna side: Attach the tag to the feeder line using binding strings through the two holes on the tag.  Equipment Side: Cover up the feeder line with the tag and fix it using RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 96 Chapter 3 Connecting Cables Category Description binding strings through the two holes on the tag. Identification method The markings must be prevented from being erased by using relief engraving or coated labels. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 97: Chapter 4 Inspect The Installation

    Inspection Plan On-site Inspection Inspection Checklist Sharing Inspection Results Inspection Checklist/Corrective Actions Taking Corrective Actions Checking the Results of Corrective Actions Sharing the Results of Corrective Actions and Preparing Preventive Plan RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 98: Table 29. Construction Situation Check List

    Validity of status and Checking fasteners omission specifications of fastening Compliance with assembly order of bolt/nut/washer, and so on fasteners Compliance with fastening torque value Insulation status Checking electrical contact between RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 99 Checking cable connection (Pin Map) Input voltage Assembly condition of a pressure terminal and connector Fastening condition of a pressure terminal and connector Checking compliance with fastening torque value Installation status of cable Position RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 100 Compliance with connector finishing Installation status of cable Position Marking content Checking tag installation method Checking compliance with fastening torque value Compliance with connector finishing Installation status of cable Position RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 101 Cable tray and duct Checking installation status Status of inside/outside of Checking the stocking condition (waste the equipment and system parts, waste materials, packing surrounding area materials, and so on) Opinion RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 102: Appendix A Acronyms

    Direct Current Down-Link Frequency Division Duplex Foiled Twisted Pair Long Term Evolution Tower Ground Bar Remote Electrical Tilting Radio Frequency Return Remote Radio Unit Up-Link VSWR Voltage Standing Waveform Ratio RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 103: Appendix B Clean The Optical Connectors

    HuxCleaner 1.25 mm Type: For LC and MU Connector Cleaning  HuxCleaner 2.5 mm Type: For SC, FC and ST Connector Cleaning Follow the manufacturer's instructions for cleaning the optical connectors. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 104: Measure The Optical Output And Connecting The Optical Connector

    If the measurement result does not meet the reference value, discard the cable, replace it with a new cable, and then clean the new one and connect it to the system. [LC/PC Plug] [Optical Power meter] RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 105: Appendix C Standard Torque

    Torque value can be different, defending on the material, characteristic and specification of the equipment and fastener. Make sure to check the proper torque value for each specification of the equipment and fastener. RFD01F Series Installation Manual v1.0 © Samsung Proprietary and Confidential...
  • Page 106 RFD01F Series Installation Manual Document Version 1.0 © 2017 Samsung Electronics Co., Ltd. All rights reserved.

Table of Contents