Verifying Power Supply Operation - Cisco ASR 1013 Quick Start Manual

Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly in your Cisco ASR 1013 router.
Check that the power supply LEDs are:
Step 1
• INPUT OK is green
• FAN OK is green
• OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the show platform command. This output is only a sample from one
of the Cisco ASR 1000 routers.
MCP_SCAL_R1#sho plat
Chassis type: ASR1006
The following output displays:
Slot
Type
1
ASR1000-SIP10
1/1
SPA-8X1GE-V2
2
ASR1000-SIP10
2/0
SPA-1X10GE-L-V2 ok
2/1
SPA-8X1GE-V2
R0
ASR1000-RP1
F0
ASR1000-ESP20
P0
ASR1006-PWR-AC
P1
ASR1006-PWR-AC
Slot
CPLD Version
1
07091401
2
07091401
R0
08060301
F0
08041102
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps, fail, then contact a customer service representatives for
assistance or additional instructions.
Start the System
After installing your Cisco ASR 1013 Router and connecting cables, start the router as follows.
Check for the following:
Step 1
• Make certain that each shared port adapter is firmly seated in its subslot and its captive screws are securely tightened.
• The Cisco ASR1000-ESP40 embedded services processors in the Cisco ASR 1013 router are inserted in slot F0 and F1, is
firmly seated in its slot, and its captive screws are securely tightened.
• All network interface cables are connected.
• The console terminal is turned on.
Turn on power. The green OK LED on the power supply turns on.
Step 2
20
State
Insert Time
ok
00:03:19
ok
00:02:23
ok
00:03:19
00:02:22
ok
00:02:17
ok,active 00:03:19
ok,active 00:03:19
ok
00:02:50
ps, fail
00:02:50
Firmware
Version
12.2(33r)XN2
12.2(33r)XN2
12.2(0:0)
12.2(33r)XN2