Verifying Power Supply Operation
Follow this procedure to verify power supply is operating correctly in your Cisco ASR 1013 router.
Check that the power supply LEDs are:
Step 1
• INPUT OK is green
• FAN OK is green
• OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the show platform command. This output is only a sample from one
of the Cisco ASR 1000 routers.
MCP_SCAL_R1#sho plat
Chassis type: ASR1006
The following output displays:
Slot
Type
1
ASR1000-SIP10
1/1
SPA-8X1GE-V2
2
ASR1000-SIP10
2/0
SPA-1X10GE-L-V2 ok
2/1
SPA-8X1GE-V2
R0
ASR1000-RP1
F0
ASR1000-ESP20
P0
ASR1006-PWR-AC
P1
ASR1006-PWR-AC
Slot
CPLD Version
1
07091401
2
07091401
R0
08060301
F0
08041102
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps, fail, then contact a customer service representatives for
assistance or additional instructions.
Start the System
After installing your Cisco ASR 1013 Router and connecting cables, start the router as follows.
Check for the following:
Step 1
• Make certain that each shared port adapter is firmly seated in its subslot and its captive screws are securely tightened.
• The Cisco ASR1000-ESP40 embedded services processors in the Cisco ASR 1013 router are inserted in slot F0 and F1, is
firmly seated in its slot, and its captive screws are securely tightened.
• All network interface cables are connected.
• The console terminal is turned on.
Turn on power. The green OK LED on the power supply turns on.
Step 2
20
State
Insert Time
ok
00:03:19
ok
00:02:23
ok
00:03:19
00:02:22
ok
00:02:17
ok,active 00:03:19
ok,active 00:03:19
ok
00:02:50
ps, fail
00:02:50
Firmware
Version
12.2(33r)XN2
12.2(33r)XN2
12.2(0:0)
12.2(33r)XN2
Need help?
Do you have a question about the ASR 1013 and is the answer not in the manual?
Questions and answers