Page 2
HEAT HERO DIRECT CONNECTED WITH AN OIL/GAS BOILER, SOLAR PANELS,AND A PRESSURE CYLINDER INSTALLATION INSTRUCTIONS - HEAT HERO DIRECT CONNECTED WITH A PRESSURISED BOILER, SOLAR PANELS, A PRESSURE CYLINDER AND A CENTRAL ZONING SYSTEM TECHNICAL DATA THERMAL SAFETY VALVE & HEAT EXCHANGER HEAT HERO INNOVATIVE PRODUCTS It is important that this information booklet is read and understood fully before installation.
Page 3
BENEFITS OF HEAT HERO DIRECT HEAT HERO DIRECT GRAVITY & COOLING LOOP Heat Hero Direct is a fully open vented heating system. Heat Hero Direct has a built-in Cooling Loop for gravity and safety. Solid Fuel Boilers can be safely connected to DHW ...
INSTALLATION INSTRUCTIONS: Heat Hero Direct is installed above the solid fuel boiler to allow gravity to pass through the solid fuel boiler and Heat Hero Direct. 2. The pipe thermostat must be of good quality and should be fitted as close to the solid fuel boiler as per diagrams. (Caution should be taken that the heat from the stove does not damage the workings of the pipe thermostat.)
Page 5
See detailed Video on website www.heathero.ie DIAGRAM SHOWING HEAT HERO DIRECT IN A DUAL HEATING SYSTEM WITH A PRESSURE CYLINDER, SOLAR, RADIATORS AND UNDERFLOOR HEATING...
Page 6
INSTALLATION INSTRUCTIONS: Heat Hero Direct is installed above the solid fuel boiler to allow gravity to pass through the solid fuel boiler and Heat Hero Direct. 2. The pipe thermostat must be of good quality and should be fitted as close to the solid fuel boiler as per diagrams. (Caution should be taken that the heat from the stove does not damage the workings of the pipe thermostat.)
Page 7
See detailed Video on website www.heathero.ie DIAGRAM SHOWING HEAT HERO DIRECT IN A HIGH PRESSURE DUAL HEATING SYSTEM WITH A PRESSURE CYLINDER, SOLAR, RADIATORS AND UNDERFLOOR HEATING...
Page 8
GENERAL TECHNICAL INFORMATION HEAT HERO DIRECT PORT 6 PORT 5 PORT 4 PORT 1 PORT 2 PORT 3 Maximum test pressure 6 Bar Overall Length 250 mm TECHNICAL DATA – HEAT HERO DIRECT Maximum work pressure 4 Bar Overall Depth...
Page 9
AFRISO Thermal Safety Valve TAS 03 The AFRISO thermal safety valve TAS 03 is used for thermal protection of sealed or open solid fuel heating systems as per EN 12828 with a heating capacity of up to 100 kW (86,000 kcal). The thermal safety valve consists of a valve housing, a valve, two independent bellow type displacement probes with liquid-filled temperature probes and a pocket.