NEC UNIVERGE SV8300 System Maintenance Manual page 23

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

E
CM35
Provide registering fault information when
long call duration of trunk call occurs.
END
NOTE 1:
Even if the external alarm is set as MN or MJ alarm for system reset (1st data=01), no alarm
is output in the case of Power On, Reset key operated, reset from the PCPro/CAT, and reset by
CPU SENSE switch selection.
NOTE 2:
The External Alarm Kind for "Number of lockout stations was more than predetermined num-
ber" is fixed as MN. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it simply
means the fault information is to be registered into Fault Memory. In this case, External Alarm
Kind cannot be changed.
NOTE 3:
The fault information of the fault kind No, 02C/03C is also registered to the CPU blade when
the OAI fault occurs/the OAI fault is restored. The OAI fault contents that are registered to the
CPU blade as follows.
• Fault Kind 02C (LAN application fault occurrence)
(a) ABOUT/RLRQ (U-ABOUT/RLRQ received)
(b) Fault detection by health check (health check IP T.O)
• Fault Kind 03C (LAN application returned to normal condition)
(a) Association is established (AARQ received)
DESCRIPTION
Chapter 1 MAINTENANCE SERVICES
Y=286
(1)
00-63: Trunk Route No.
(2)
0 : Not provided
1 : To provide
1-11
FAULT MESSAGE
DATA
NWA-033627-001 Rev.4.0
95ch1001.fm
APRIL/16/2010