Parameter
4.02.024 Ethernet MTU
Short description
Specifies the MTU for the Ethernet interface
Minimum
158
Default
1500
Type
16 Bit User Save
Display Format
Standard
Coding
RW, BU
This parameter is now deprecated. The maximum Ethernet packet size is now 400 bytes.
Parameter
4.02.025 Gateway Mode
Short description
Specifies the operation mode of the gateway
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE, BU
Value
Text
0
Switch
1
Gateway
2
Strict Gateway
Specifies the operation mode of the gateway. By default the gateway is disabled and the switch operates in normal switch mode, by enabling the
gateway mode all packets are filtered by the module and prioritised before being forwarded on. In strict mode the gateway will drop packets from
unsupported protocols.
VLAN must be enabled VLAN Enable (4.02.030) when the gateway is enabled.
Parameter
4.02.030 VLAN Enable
Short description
Enables VLAN tagging
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
Controls whether the module will use VLAN tagging.
When used in conjunction with Drive VLAN ID (4.02.031) network traffic from the interface will be tagged with the chosen VLAN identifier.
When default values for Drive VLAN ID (4.02.031) is set, enabling this parameter will add VLAN prioritisation to all packets helping to ensure real-time
packets are not delayed by those of lower priority. If disabled, prioritisation will use the Diffserv field in IP traffic only, meaning non-IP traffic can still
affect real-time IP traffic.
Parameter
4.02.031 Drive VLAN ID
Short description
Specifies a VLAN ID that the drive (Port 0) will be a member of
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, BU
Specifies the VLAN ID that the interface will be a member of. Any packets entering the switch without this VLAN ID will not be handled.
Parameter
4.02.034 Drive compatibility mode
Short description
Specifies the mimic of the GT8 from a PLC for EthernetIP and Modbus
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE, BU
Defines the parameter conversion for EthernetIP and Modbus.
Value
Text
0
Unidrive M
1
Unidrive SP
498
Maximum
1500
Units
Bytes
Update Rate
Read on module reset
Decimal Places
0
Maximum
2
Units
Update Rate
Read on module reset
Decimal Places
0
Maximum
1
Units
Update Rate
Read on module reset
Decimal Places
0
Maximum
255
Units
Read on module reset and
Update Rate
VLAN_ENABLE
Decimal Places
0
Maximum
1
Units
Update Rate
Read on module reset
Decimal Places
0
Unidrive M702 Parameter Reference Guide
Issue: 01.16.01 (Eth 01.07.00)
Need help?
Do you have a question about the Unidrive M702 and is the answer not in the manual?
Questions and answers