Quick Start

SPD3303X/3303X-E
Programmable DC Power Supply
QS0503X-E01B
2015 SIGLENT TECHNOLOGIES CO., LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPD3303X and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGLENT SPD3303X

  • Page 1: Quick Start

    Quick Start SPD3303X/3303X-E Programmable DC Power Supply QS0503X-E01B 2015 SIGLENT TECHNOLOGIES CO., LTD...
  • Page 3: Trademark Information

    SIGLENT TECHNOLOGIES CO., LTD. All rights reserved. Trademark Information SIGLENT is registered trademark of SIGLENT TECHNOLOGIES CO., LTD. Statement ● SIGLENT products are protected by patent laws in and outside of the P.R. China. ● SIGLENT reserves the rights to change the specification and price. ●...
  • Page 4: General Safety Summary

    SIGLENT General Safety Summary Please review the following safety precautions carefully to avoid personal injury or damage to this product or any product connected to it. To prevent potential danger, please use the instrument as specified. Use proper power cord Only the power cord designed for the instrument and authorized by local country could be used.
  • Page 5 SIGLENT Do not operate in an explosive atmosphere To avoid personal injury or damage to instrument, please do not operate in an explosive atmosphere. Keep surface of the product clean and dry To avoid dust or moisture in the air influence the performance of the instrument , please keep surface of the product clean and dry.
  • Page 6: Safety Terms And Symbols

    SIGLENT Safety Terms and Symbols Terms may appear on the product: DANGER: Indicates direct injury or hazard that may happen. WARNING: Indicates potential injury or hazard that may happen. CAUTION: Indicates potential damage to the instrument or other property that may happen.
  • Page 7: Spd3303X/3303X-E Brief Introduction

    SIGLENT SPD3303X/3303X-E Brief Introduction SPD3303X/3303X-E Programmable DC Power Supply is convenient, flexible and multi-function. It has three independent outputs, two sets of adjustable voltage value and a fixed set of selectable voltage value of 2.5V, 3.3V, and 5V, and it also provides output short circuit and overload protection at the same time.
  • Page 8: Table Of Contents

    SIGLENT Content Copyright and Statement .................. I General Safety Summary ................. II Safety Terms and Symbols ................IV SPD3303X/3303X-E Brief Introduction ............V Chapter 1 Start Guide ..................1 General Inspection ....................2 Safety Considerations ..................... 3 The front panel ......................
  • Page 9: Chapter 1 Start Guide

    Chapter 1 Start Guide In this chapter, we mainly introduce the panel and display Interface of SPD3303X/3303X-E, as well as the new machine inspection and attentions at first use. Reading this chapter will give you a quick understanding on operation.
  • Page 10: General Inspection

    The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement. 2. Inspect the instrument.
  • Page 11: Safety Considerations

    SPD3303X/3303X-E Input Power Requirement The SPD3303X/3303X-E allows a 50Hz/60Hz frequency, and four levels of AC power: 100V/120V/220V/230V. You can select wanted power voltage with the “DIP Switch” at the rear panel according to the actual demand.
  • Page 12: The Front Panel

    SIGLENT The front panel ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Description Description ○ ○ Logo CH3 DIP Switch ○ ○ Display Area Power Switch ○ ○ Model CH1 Output Terminal System parameter ○...
  • Page 13 SIGLENT Buttons for setting parameters Press the button to turn on/off the waveform display interface; Press the button to set series mode of CH1/CH2, and the logo “ ” displays at the same time; Press the button to set parallel mode of CH1/CH2, and the logo “...
  • Page 14 SIGLENT Other buttons Select the digit position by moving the cursor around Right/Left Direction button. Press the button to move the cursor around The output terminal on front panel The output terminals of CH1, CH2 and CH3 include positive terminal and negative terminal, and a common ground for CH1 and CH2 additional.
  • Page 15: User Interface

    SIGLENT User interface ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Parallel/Series logo: The logo will be displayed when the corresponding mode is on ○ Channel logo ○ Operating mode logo: The corresponding logo will display when working in CV or CC mode;...
  • Page 16: The Rear Panel

    SIGLENT The rear panel ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ warning message ○ The DIP switch of the AC power and its identification. ○ The description of the AC input voltage ○ AC power socket ○...
  • Page 17: Output Check

    SIGLENT Output check The output check includes voltage check in condition of all channels with no load and current check in condition of short circuit so as to make sure that the instrument correctly responds to operation of the front panel.
  • Page 18: Chapter 2 Control Panel Operation

    SIGLENT Chapter 2 Control panel operation In this chapter, the function and operation of SPD3303X/3303X-E control panel will be introduced in detail to give you an all-around understanding of it, which will eventually lead to easier work. Brief introduction:  Output summary ...
  • Page 19: Output Summary

    SIGLENT 2.1 Output summary SPD3303X/3303X-E have three independent outputs, two of which are adjustable in voltage value and the other one includes selectable 2.5V, 3.3V or 5.0V Independent/Parallel/Series SPD3303X/3303X-E have three output modes: independent 、parallel and series, which can be selected through the track switch on the front panel. In the independent mode, the output current and voltage are controlled respectively.
  • Page 20: Ch1/Ch2 Independent Output

    SIGLENT 2.2 CH1/CH2 Independent Output Instruction CH1 and CH2 are working in the independent mode, at the same time,they are insulated from the ground. Output rating 0~32V/0~3.2A Operation steps 1. Make sure that parallel/series mode is off. 2. Connect load to the positive and negative terminals of CH1/CH2.
  • Page 21: Ch3 Independent Mode

    SIGLENT 2.3 CH3 Independent mode Instruction CH3 is independent from CH1 and CH2, and it works neither in parallel mode nor in series mode. Its voltage and current ratings are respectively 2.5V, 3.3V, 5V and 3.2A. Output ratings 2.5V/3.3V/5V, 3.2A Operation steps: 1.
  • Page 22: Ch1/Ch2 Series Mode

    SIGLENT 2.4 CH1/CH2 Series mode Instruction In the series mode, CH1 and CH2 are linked internally into one channel which is controlled by CH1, and the output voltage value is twice compared with that of single channel. Output rating 0~64V/0~3.2A Operation steps:...
  • Page 23: Ch1/Ch2 Parallel Mode

    SIGLENT 2.5 CH1/CH2 Parallel mode Instruction In the parallel mode, CH1 and CH2 are linked internally into one channel which is controlled by CH1. Its output current value is twice as much as the single channel. Output rating 0~32V/0~6.4A Operation steps: 1.
  • Page 24: Lan Setting

    SIGLENT 2.6 LAN setting Operation steps: 1. Connect the oscilloscope to your local area network using the network cable. 2. Press the “IP/Store” button to enter LAN setting interface. 3. Press the direction button to go to the DHCP line, then revolve the...
  • Page 25: Save And Recall

    SIGLENT 2.7 Save and Recall Five group setups can be saved in memory. The contents of the setup file including:  Independent/series/parallel mode  Output voltage/current value  Timer setup Save setup Operation steps: 1. Set the state that you wanted;...
  • Page 26: Timer

    SIGLENT 2.8 Timer The timer works in the Independent mode, and can save five timing setups, each of which is independent from each other. You can set any voltage/current value within the range as you want. The timer supports consecutive output, and the longest time of each group is 10000s.
  • Page 27 SIGLENT Turn on/off the Timer Method 1: 1. Press “1”/”2” button to select the wanted channel in the main interface; 2. Move cursor to “TIMER” menu by pressing the direction button 3. Revolve the multi-function knob to make the Timer state to “ON”;...
  • Page 28 SIGLENT If press the “on/off” button to turn off the output when the timer is running, then the countdown will stop. And the countdown will continue when the channel output is turn on again. The Timer will automatically turn off when the time reduces to 0.
  • Page 29: Waveform Display

    SIGLENT 2.9 Waveform display SPD3303X/3303X-E can display the changing of current voltage and current in real time in the form of curve drawing. Operation steps: 1. Select CH1/CH2, and then set voltage/current parameter; 2. Press “Wavedisp” button to enter Waveform Display interface, and the indicator light turns bright immediately.
  • Page 30: Version Information

    SIGLENT 2.10 Version information Short press button to enter Version Information interface, which is shown below: Long press button in any interface to open keylock function, which will make all the keys invalid, and the graphic logo of “lock” will display at the same time.
  • Page 31: Upgrade Firmware

    SIGLENT 2.11 Upgrade firmware The software of the instrument is upgraded with a fixed name file via PC management software with USB or LAN. The upgrade method is below: Upgrade in normal Interface 1. Open the EasyPower software after USB line or network cable having been connected perfectly, and make sure the instrument is connected with the software normally;...
  • Page 32 SIGLENT Figure 2 Figure 3 4. As it shows in figure 4, click “Upgrade”, a dialog will popup as it shows in figure 5 and then select the upgrade method—USB(USBTMC)or LAN (VXI11) . The upgrade is finished when the progress bar complete and the instrument will run the version after upgrade.
  • Page 33 SIGLENT Figure 4 Figure 5 Upgrade Via Guide Procedure Upgrade via guide procedure also can be used if the method above is failed. Specific steps are below: 1. Press the knob before powering on the instrument, and the turn on the instrument and it will enter the guide procedure mode.
  • Page 34: Chapter 3 Remote Control

    SIGLENT Chapter 3 Remote control SPD3303X/3303X-E support communication with computer through USB and LAN interface on the rear panel. SCPI (Standard Commands for Programmable Instruments) is an ASCII-based programming language, which can be used to control power supply remotely by computer installed with EasyPower software or NI (Measurement &...
  • Page 35: Syntax Conventions

    SIGLENT 3.1 Syntax Conventions Most commands are a mixture of upper- case and lower-case letters. The upper-case letters indicate the command's abbreviated spelling, which yields shorter program lines. For better program readability, use the long form. For example: [{CH1|CH2}:]VOLTage <voltage>...
  • Page 36: Command List

    SIGLENT 3.2 Command list 1. *IDN? 2. *SAV 3. *RCL 4. INSTrument Subsystem 5. MEASure Subsystem 6. CURRent Subsystem 7. VOLTage Subsystem 8. OUTPut Subsystem 9. TIMEr Subsystem 10. SYSTem Subsystem 11. IPaddr Subsystem 12. MASKaddr Subsystem 13. GATEaddr Subsystem 14.
  • Page 37: Command Description

    Query the manufacturer, product type, series No., software version and hardware version Return Info Manufacturer, product type, series No., software version, hardware version Typical Return Siglent Technologies, SPD3303X, SPD00001130025, 1.01.01.01.02,V3.0 2. *SAV Command format *SAV {1|2|3|4|5} Description Save current state in nonvolatile memory...
  • Page 38 SIGLENT Command format INSTrument? Description Query the current operating channel Example INSTrument? Typical Return 5. MEASure Command format MEASure: CURRent? [{CH1|CH2}] Description Query current value for specified channel, if there is no specified channel, query the current channel. Example MEASure: CURRent? CH1 Typical Return 3.000...
  • Page 39 SIGLENT 6. CURRent Command format [{CH1|CH2}:]CURRent <current> Description Set current value of the selected channel Example CH1:CURRent 0.5 Command format [{CH1|CH2}:]CURRent? Description Query the current value of the selected channel. Example CH1: CURRent? Typical Return 0.500 7. VOLTage Command format [{CH1|CH2}:]VOLTage <voltage>...
  • Page 40 SIGLENT 8. OUTPut Command format OUTPut {CH1|CH2|CH3},{ON|OFF} Description Turn on/off the specified channel output. Example OUTPut CH1,ON Command format OUTPut:TRACK {0|1|2} Description Select operation mode. Parameters {0|1|2} mean independent, series and parallel respectively. Example OUTPut: TRACK 0 Command format OUTPut:WAVE {CH1|CH2},{ON|OFF}...
  • Page 41 SIGLENT Example TIMEr:SET? CH1,2 Typical Return 3,0.5,2 Command format TIMEr {CH1|CH2},{ON|OFF}; Description Turn on/off Timer function of specified channel Example TIMEr CH1,ON 10. SYSTem Command format SYSTem: ERRor? Description Query the error code and the information of the equipment. Typical Return...
  • Page 42 SIGLENT Bit No. Corresponding state 0: CH1 CV mode; 1: CH1 CC mode 0: CH2 CV mode; 1: CH2 CC mode 01: Independent mode; 10: Parallel mode 0: CH1 OFF 1: CH1 ON 11: Series mode 0: CH2 OFF 1: CH2 ON...
  • Page 43 SIGLENT Command format MASKaddr? Description Query the current subnet mask of the instrument Typical Return 255.255.255.0 13. GATEaddr Command format GATEaddr <GateWay> Description Assign a gateway for the instrument Example GATEaddr 10.11.13.1 Note The command is invalid when the state of DHCP is on...
  • Page 44: Chapter 4 Troubleshooting

    SIGLENT Chapter 4 Troubleshooting Question 1: What to do if a short circuit on output terminal occurs? Answer1: There are over current protection and short circuit protection inside the power, so current will be controlled in safety range. Question 2: Is it abnormal that the CH3 overload indicator is lit? Answer 2: No, that only means the current value reaches 3.2A, which is the...
  • Page 45: Chapter 5 Service And Support

    Chapter 5 Service and Support Maintain summary SIGLENT warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of three years from the date of shipment from an authorized SIGLENT distributor. If a product or CRT proves defective within the respective period, SIGLENT will provide repair or replacement as described in the complete warranty statement.