Flue Gas Temp at
Flue Gas
Spigot
Mass Flow
O
402
C
3.9 g/s (wood)
9.7 g/s (ancit)
As tested to the requirements of EN13240 for intermittent use.
Output
Anthracite
Wood Logs (less than 20% moisture)
Coal (E)
Peat (E)
Closed Fire Briquettes
Outputs stated are under ideal test conditions. Variations will occur due to installation, atmospheric
conditions and fuel quality.
(E) - estimate calculated
Essential characteristic
Test fuel
Fire Safety
Emission of combustion products, related to 13% O
Surface Temperature
Thermal output / Energy efficiency
Release of dangerous substances
email sales@percydoughty.com
Flue Diam
Ventilation
Ventilation Reqt
Reqt
with draught
125mm
None
5 inches
Output kW
Firefox 5
4.6
4.9
4.3
4.7
4.6
Performance
Beech
Anthracite
Pass
CO: 0.11 vol%
CO: 0.17 vol%
2
3
Dust: 73 mg/m
Dust: 86 mg/m
0
3
NO
: 98 mg/m
x
0
3
C
H
: 183 mg/m
x
y
0
Pass
4.9kW / 79.4%
4.5kW / 67.4%
Pass
Percy Doughty & Co.
Imperial Point, Express Trading Estate,
Stone Hill Road
Farnworth, Bolton, BL4 9TN
16
Telephone 01204 868550
Fax 01204 868551
web www.percydoughty.co.uk
stabilizer
2
1500mm
2
2.33in
INSTALLATION AND OPERATING INSTRUCTIONS
Cycle
Hours
4
1
4
2
4
Pass
3
0
Pass
Pass
The Firefox Stove operates at very high temperatures. All persons including children
and the infirm should be warned of this and not be allowed to touch any surfaces
whilst in use. The operator must use the tools provided. The mitten provided is a tool.
FIREFOX
CAST IRON MULTI-FUEL STOVE
V 5.2
Conforms to EN13240:2001
Constructional Requirements
For Intermittent Use
Not to be used in a shared flue
FIREFOX 5 CLEAN BURN II
(to be left with the householder)
APPROVED
Need help?
Do you have a question about the FIREFOX 5 CLEAN BURN II and is the answer not in the manual?
Questions and answers