5 COMMISSIONING
Follow the steps described below for commissioning
of the Li-ion battery:
1. Check all wiring and connections; see also the
figures in chapter 4 for wiring details.
2. Install all fuses.
3. Switch on some loads.
4. Verify that a current is flowing out of the battery
(negative current).
5. Switch off the load, switch on the charger and
verify that a current is flowing into the battery
(positive value).
EN / Lithium-ion Battery MLI-E / 10000013074_01
6. Depending on the installation in which the Li-ion
battery is used, programming of additional
MasterBus events may be required. See chapter
6.
7. Charge the Li-ion battery fully until the charger
switches to the float stage (maintenance charge)
of the charging algorithm.
Now the Li-ion battery is ready for operation.