Installation Manual Aquastat wells Closed- Large tank provided for cell foam connections monitoring and insulation accommodate controlling tank provides low flow rates temperature standby loss required by low mass equipment A division of: www.BoilerBuddy.com REV. 11/17...
Page 2
Reference to System Configurations and Specifications supercede all previous information and are subject to change without notice. Boiler Buddy® is a registered trademark of Hot Water Products, Inc.
Page 3
Specifications BB-80-C Specifications Page Concept Drawings / Schematics BB-18 | BB-30 with Boiler BB-30 with Boiler & Indirect Water Heater BB-30 with Boiler & Indirect Multi-Temp BB-50-G with Geo-Thermal BB-80-3W with Two Boilers & Indirect BB-80-C with Boiler & Wood Boiler BB-80-C with Geo-Thermal &...
Page 4
| Boiler Buddy® Installation Manual Boiler Buddy® Buffer Tank Models: BB-18, BB-30, BB-50-G, BB-80-3W, BB-80-C & BB-119-3W • The BB-18 and BB-30 come with 1 aquastat well. • The BB-50-G, BB-80-3W, and BB-119-3W come with 3 aquastat wells. • The BB-80-C comes with an internal heat exchanger coil and 1 aquastat well.
Page 5
It also greatly enhances structural integrity and retards water and moisture, thereby increasing the longevity of the tank. ! WARNING ! Boiler Buddy Tanks include the following: Boiler Buddy buffer tanks are NOT • Premium high capacity air • All necessary nipples...
Page 6
| Boiler Buddy® Installation Manual Model: BB-80-C The BB-80-C is the only Boiler Buddy model that comes with an internal carbon steel heat exchange coil. This feature allows for flexibility in system design. Design applications include; hydronic buffer tank/heat supplemented by solar, geothermal, wood boiler, pellet stove, waste oil burner, etc.
Page 7
REV. 7/16 | Boiler connections to the Boiler Buddy should be made as illustrated in the following piping diagrams. If the boiler connections are reversed, the system supply temperature could be tempered within the tank. To achieve maximum set point, feed the boiler supply into the top tapping.
Page 8
| Boiler Buddy® Installation Manual Drawing is meant to show system piping concepts only. Installing contractor is responsible for all equipment and detailing required by local codes.
Page 9
REV. 7/16 | Drawing is meant to show system piping concepts only. Installing contractor is responsible for all equipment and detailing required by local codes.
Page 10
| Boiler Buddy® Installation Manual Drawing is meant to show system piping concepts only. Installing contractor is responsible for all equipment and detailing required by local codes.
Page 11
REV. 7/16 | Drawing is meant to show system piping concepts only. Installing contractor is responsible for all equipment and detailing required by local codes.
Page 12
Drawing is meant to show system piping ized systems with air elimination! concepts only. Installing contractor is Boiler Buddy Tank NOT suitable for responsible for all equipment and detailing potable water! required by local codes.
Page 13
This must only be connected to closed-loop, pressurized Drawing is meant to show system piping systems with air elimination! concepts only. Installing contractor is Boiler Buddy Tank NOT suitable for responsible for all equipment and detailing potable water! required by local codes.
Page 14
11 | Boiler Buddy® Installation Manual ! WARNING ! The internal coil in the BB-80-C tank is made of carbon steel. This must only be connected to closed-loop, pressurized Drawing is meant to show system piping systems with air elimination! concepts only.
Page 15
REV. 7/16 | 12 Drawing is meant to show system piping concepts only. Installing contractor is responsible for all equipment and detailing required by local codes.