UEi CLM100 Instruction Manual

UEi CLM100 Instruction Manual

Cable length meter

Advertisement

CLM100
Cable Length Meter
INSTRUCTION MANUAL
ENGLISH
1-800-547-5740
www.ueitest.com • email: info@ueitest.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLM100 and is the answer not in the manual?

Questions and answers

Summary of Contents for UEi CLM100

  • Page 1 CLM100 Cable Length Meter INSTRUCTION MANUAL ENGLISH 1-800-547-5740 www.ueitest.com • email: info@ueitest.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENT Introduction Features icludes Safety Tips International Symbol Instructions Calibration Procedures Measuring Length of Wire Low Battery Indication Measuring Resistance Specifications Operational Hints Warranty Disposal Cleaning Storage...
  • Page 3: Introduction

    INTRODUCTION The CLM100 Cable Length Meter is ideal for measuring cable length on the spool or in existing conduits. Includes test leads, copper calibration bar, an abrasive pad for removing oxidation and carrying case. Features include • 3 digit display with enunciators •...
  • Page 4: Instructions

    INSTRUCTIONS Calibration Procedures Turn the CLM100 on by depressing the green on/off button Insert the black test leads into one pair of input jacks and the red test leads into the other pair of input jacks. (Ignore the gray marking on the banana plug.) This is very important to ensure that the meter works correctly.
  • Page 5: Measuring Length Of Wire

    Kelvin clips can be connected across the diameter of the wire. Use the abrasive pad to clean the wire ends. Using the selector on the CLM100, turn to the size of wire under test. Press the “COPPER” button if copper wire is being tested.
  • Page 6: Specifications

    SPECIFICATIONS Measurement Range: 25 to 30,000 feet 26ga to 4/0ga 250MCM to 500MCM Accuracy: Ambient Temperature: 65˚ to 75˚F < 30ft: ±6 LSD > 30ft: ±(2% of reading + 3 LSD) Ambient Temperature: <65˚ and >75˚F < 30ft: ±6 LSD >...
  • Page 7: Operational Hints

    OPERATIONAL HINTS • Never apply voltage to the inputs. • Temperature affects readings. Allow the CLM100 to attain the ambient temperature of the wire under test. • Use a 9 Volt alkaline battery only • Use the test leads that came with the unit only. Other leads will not work.
  • Page 8: Warranty

    WARRANTY The CLM100 is warranted to be free from defects in materials and workmanship for a period of five years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance.