i7 0 In s t r u m e n t User MANUAL d is p la y Us e r re fe re nce Docume nt numbe r: 81330-1 Da te : 11-2010...
Page 2
, SeaTalk and Sportpilot are registered trademarks of Raymarine UK Limited. RayTalk, Seahawk, Smartpilot, Pathfinder and Raymarine are registered trademarks of Raymarine Holdings Limited. FLIR is a registered trademark of FLIR Systems, Inc. and/or its subsidiaries. All other trademarks, trade names, or company names referenced herein are used for identification only and are the property of their respective owners.
(as applicable). Connections to other equipment Raymarine does not warrant that this product is error-free or that it is compatible with products manufactured by any person or entity Requirement for ferrites on non-Raymarine cables other than Raymarine.
2.1 About this handbook 2.2 i70 Handbooks This handbook describes how to operate your product in conjunction The i70 Instrument has the following handbooks available: with compatible peripheral equipment. i70 Handbooks It assumes that all peripheral equipment connected to the system...
Page 7
Calibrate essential data Before using the i70 you must calibrate essential data to ensure that the readings displayed are accurate. Use the transducer Setup menu: Main menu > Setup > Transducer setup to calibrate.
3.1 System integration The i70 Instrument provides multiple marine instrument functions in a single unit. The instrument displays information received from transducers and other sensors around the boat. There are multiple pages of information available, which you can customize to suit your needs.
Page 10
Item Device type SeaTalk GPS receiver SeaTalk Pilot controllers Raymarine Multifunction displays AIS receiver / transceiver Transducer pods Analogue wind transducers Analogue speed transducers Analogue depth transducers Other devices not shown: Smart transducers (e.g. DST800, DT800) NMEA2000 devices (e.g. trim tab control, engine data)
2. Continue to hold the LEFT SOFT button for a further 3 seconds to complete the power off D12065-1 Item Description LEFT SOFT BUTTON Power, brightness, cancel, back UP ARROW Up navigation, Adjust Up DOWN ARROW Down navigation, Adjust Down RIGHT SOFT BUTTON Menu, select, OK, Save i70 Instrument display User reference...
A list of network groups will be displayed: Display and shared color • None (default) The i70 can set a color scheme for the individual display or for the • Helm 1 system (if color is available on the network displays).
Changing the color scheme 1. From the color menu highlight a color scheme. Once highlighted the display will preview the selected color scheme. 2. Press SELECT to confirm the color scheme and return to the color settings menu. i70 Instrument display User reference...
D12070-1 The i70 presents instrument data on a series of pages. You can have a minimum of 1 and a maximum of 10 favorite pages available, There are sixteen different page layouts to choose from which can be customized with different data types.
Page 16
4.2 Favorite page frames Analog frames Each piece of information is displayed in a frame within the page. The frames support a number of different styles and formats for presenting the data. Tri data frame D11838-1 Analog frames provide real-time data in the form of an analog gauge. Analog gauges are only available for full and 2/3 screen frames.
Page 17
Multi gauge frames Minimum value The i70 provides three multi-gauge frames for use as favorite pages Average value which you can see below: Maximum value indictor Multi-gauge — sailing vessel Graph frames D12072-1 Multi-gauge — single engine vessel D11840-1 Graphs provide a means of showing how a particular reading has changed over time.
Page 18
Race timer frame Multi gauge — twin engine vessel Ra c e tim e r TART D12076-1 D12074-1 The race timer provides the ability for up to 3 countdown timers. Trim tab frame See Race timer chapter for more details. AIS frame D12075-1 The trim tab frame provides information on the position of the trim...
Page 19
2. Select Quick options by pressing the RIGHT SOFT button. 3. Select reset against the data you want to reset and press the D11861-1 RIGHT SOFT button. The rolling road provides waypoint and course deviation information. i70 Instrument display User reference...
4.4 Customizing pages 2. Select Favorites page from the menu. 3. Select New page from the menu. You can use the Favorites page menu to change any instrument If you already have the maximum number of pages set up you page to suit your requirements.
Page 21
2. To turn rollover function on select a time interval and press SELECT to confirm. 3. To turn rollover off select Off and press SELECT to confirm. i70 Instrument display User reference...
The AIS feature enables you to receive information broadcast by other vessels, and to view these vessels as targets relative to your boat. The AIS feature on i70 is standalone, settings and alarms cannot be shared with other AIS enabled products on your system.
5.2 AIS target symbols AIS Messages Description Alarm on icon AIS on, transmitting, alarm is active. Your display shows a range of symbols to represent the different types of AIS target. Silent AIS on & user is silent to other vessels. Target type Description Symbol...
Page 25
Aid To Navigation (AToN) AToN target is OFF target (Virtual) position & dangerous. Target black and flashes. Aid To Navigation (AToN) AToN target is OFF target (Virtual) position & lost. Target black with red cross and flashes. i70 Instrument display User reference...
5.3 Setting AIS range 5.4 Viewing AIS target information You can change the scale of the AIS page by altering the AIS range. Whilst on the AIS page you can view information about AIS targets by following the steps below: 1.
3. Highlight the AIS Silent option and press OK . There are two options to choose from: • Silent • Transmit 4. To turn on Silent mode highlight Silent and press SELECT. 5. To turn off Silent mode highlight Transmit and press SELECT. i70 Instrument display User reference...
Page 28
Chapter 6: Race timer settings Chapter contents • 6.1 Setting the race timer • 6.2 Using the race timer Race timer settings...
• Beep Three times at the start of the last 30 seconds. • Adjust start times • Beep every second for the last 10 seconds. • Beep for two seconds when the timer reaches zero i70 Instrument display User reference...
Chapter 7: Multiple data sources (MDS) Chapter contents • 7.1 Multiple data source (MDS) overview • 7.2 Viewing vessel data sources • 7.3 Selecting a preferred data source Multiple data sources (MDS)
Page 31
You will now see detailed information about the data source • Speed which will include: • Wind • Device Note: The presence of some non-MDS compliant devices on • Serial number your system may prevent MDS from working. • Port ID • Status i70 Instrument display User reference...
Page 32
7.3 Selecting a preferred data source To select a preferred data source for your system: 1. Go to the MDS menu: Main menu > Setup > System setup > Multiple data source. 2. Press OPTIONS. 3. Highlight Selection and press SELECT. 4.
Note: With the exception of alarm clock, speed and sea temp SeaTalk systems will only be able to switch alarms on/off, Adjust • 0 — xxx FT SeaTalk systems will be able to adjust settings. • 5 ft (default) i70 Instrument display User reference...
Page 35
Category Alarm Content Category Alarm Content Depth Deep Alarm • On Temperature Sea Temp. High Alarm • On • Off (default) • Off (default) Adjust • 0 — xxx FT Adjust • 0 — 50ºC • 100 ft (default) • 10ºC (default) Depth Shallow Anchor Alarm...
Page 36
• Off (default) • 25º (default) Adjust • 6 – 60 V Wind TWA Low Alarm • On • 10 V (default) True Wind Angle • Off (default) Adjust • 0 — 180 º • 10º (default) i70 Instrument display User reference...
Page 37
Category Alarm Content Other AIS Alarm Safety • On messages • Off (default) Dangerous • On target • Off (default) Safe zone • (0.1 , 0.2, 0.5, 1.0, 2.0) nm • (0.1 , 0.2, 0.5, 1.0, 2.0) sm • (0.2, 0.5, 1.0, 2.0, 5.0) km Time to safe •...
Reset Max. Air Temperature Minimum Air Temperature Reset Min. Air Temperature Maximum AWA Reset Maximum. AWA Minimum AWA Reset Minimum. AWA Maximum AWS Reset Max. AWS Minimum AWS Reset Min. AWS Maximum TWA Reset Max. TWA i70 Instrument display User reference...
Page 40
Page displayed Quick options available Minimum TWA Reset Min. TWA Maximum TWS Reset Max. TWS Minimum TWS Reset Min. TWS Race Timer Start timer Stop timer Reset timer Adjust start times Graph Time scale (View data) page Add to favorites View AIS targets —...
Page 43
Menu item / description Settings / operation Menu item / description Settings / operation Fuel Fuel management is dependant on a Environment • Air temperature suitable fuel or engine management • Air temperature history system being available on the SeaTalk network.
Page 44
• Heading history • Locked heading Pilot • Course to steer • Locked heading error & locked • Pilot heading heading • Pilot heading & speed pair • Tack heading • Pilot status • Rudder angle i70 Instrument display User reference...
Page 45
Menu item / description Settings / operation Speed • Average speed • Boat speed & SOG • Max speed • Speed • Speed history • Trolling • VMG windward • VMG windward history • VMG WPT • VMG WPT history Time •...
Page 46
• AWS min • Beaufort • Cardinal • GWD • GWD history • GWD + Beaufort • TWD • TWD history • TWA • TWA history • TWA & TWS pair • TWA(CH) & TWS pair i70 Instrument display User reference...
10.2 Viewing data You can use the View data menu to view information which has not been added to favorite pages. 1. Select View data menu from the main menu. 2. From the Select Category menu choose the data category. 3.
Chapter 11: Setup menu Chapter contents • 11.1 Setup menu Setup menu...
Page 49
System set up Set system network • Network group groups, display and • Brightness / color system color and group brightness, Multiple data sources and about • Multiple data sources system setup • About system setup i70 Instrument display User reference...
Transducer setup menu The Transducer setup menu provides the functions to enable setup and calibrate connected transducers. Menu item Description Options Depth Enables setup and calibration of depth transducers Details displays can supply information about the and provides the following options: installed transducer or interface such as Serial No.
Page 51
• Add — adds a new speed setting using current SOG reading. • Edit — edits a speed setting in 0.1 kt increments. • Delete — deletes the selected speed setting. • Reset — resets speed calibration to default settings. i70 Instrument display User reference...
Page 52
Menu item Description Options Temperature offset: • xxx ºC or ºF DT800 Enables setup and calibration of DT (Depth, and DT800 details displays information about the Temperature) smart transducers and provides the installed transducer, Serial No. and Software version following options: etc.
• Temperature • sm — Statute miles. • Flow rate • km — Kilometres. • Heading Depth: • Pressure • ft — Feet • Volume • m — Metres • Barometric • fa — Fathoms i70 Instrument display User reference...
Page 54
Menu item Description Options Wind speed: • kts — knots. • m/s — metres per second. Temperature: • ºC — degrees centigrade. • ºF — degrees fahrenheit. Flow rate • UK Gal/H — UK gallons per hour. • US Gal/H — US gallons per hour. •...
Page 55
• English — UK • English — US • Finnish • French • German • Greek • Italian • Japanese • Korean • Norwegian • Polish • Portuguese (Brazilian) • Russian • Spanish • Swedish • Turkish i70 Instrument display User reference...
Page 56
Menu item Description Options Vessel type Determines the default setup of the unit and favorite • Race sail pages • Sail cruiser • Catamaran • Workboat • RIB • Outboard speed boat • Inboard speed boat • Power cruiser 1 •...
Page 57
Menu item Description Options Variation range: • -30º — +30º i70 Instrument display User reference...
System setup menu The System setup menu enables users to customize user settings as detailed in the table below: Menu item Description Options Network group This allows you to add multiple units together in a Pre-defined groups group so that when the color scheme or brightness is •...
Page 59
Multiple Data source allows you to view & manage which Data source is used on your pilot head. Data types include: GPS Position, Heading, Depth, Speed & Wind. i70 Instrument display User reference...
The simulator mode is switched on/off in the Simulator option from the Setup Menu. Note: Raymarine recommends that you do NOT use the simulator mode whilst navigating. Note: The simulator will NOT display any real data, including any safety messages (such as those received from AIS units).
Page 61
• Run time • Deviation (If available) About system Allows you to view information about products on the • Model number system you are using: • Serial number • Software version • Hardware version • Volts i70 Instrument display User reference...
Page 62
Menu item Description Options Key beep Enables you to turn on and off the audible beeps • On when keys are pressed • Off Self test The product has a built in self test which can help • Memory test to diagnose faults.
12.1 Service and maintenance This product contains no user serviceable components. Please Raymarine strongly recommends that you complete a number of refer all maintenance and repair to authorized Raymarine dealers. routine checks to ensure the correct and reliable operation of your Unauthorized repair may affect your warranty.
12.3 Cleaning 12.4 Cleaning the display screen Best cleaning practices. A coating is applied to the display screen. This makes it water repellent, and prevents glare. To avoid damaging this coating, follow When cleaning this product: this procedure: • Do NOT wipe the display screen with a dry cloth, as this could 1.
12.5 Performing a factory reset To reset your i70 to factory settings follow the steps below. Note: Performing a factory reset will erase all saved data and customized settings. 1. Press the RIGHT SOFT button to open the main menu.
Raymarine provides a comprehensive customer support service. 1. From the main menu scroll to Set Up and press the SELECT key. You can contact customer support through the Raymarine website, 2. From the Set Up menu scroll to Diagnostics and press the telephone and email.
Need help?
Do you have a question about the i70 and is the answer not in the manual?
Questions and answers