  • Page 1 Commercial Series Installation Instructions Health Relaxation Exhilaration Heat Spa Kur Therapy Development Inc...
  • Page 2 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS: SW-10, SW-12 and SW-18 COMMERCIAL SERIES GUIDELINES FOR STEAM ROOMS Walls, ceiling and fl oor must be completely covered with waterproof fi nish; tile, marble, stone or slate. Any smooth surface fl ooring that is used such as tile or marble, should include an anti-skid fi nish to avoid slipping and injury.
  • Page 3 Larger Generators are available. • Steam-Whirl’s revolutionary LED self analysis system in the Standard Series generator simplifi es installation and monitors for proper electrical and water feed at all times. •...
  • Page 4 Development INSTALLATION, OPERATION & MAINTENANCE MANUAL GENERATOR SIZING GUIDE MAXIMUM CUBIC BREAKER WIRE MODEL FEET VOLTS PHASE AMPS SIZE SIZE CAPACITY @ 100’ SW-10BD 6AWG SW-10-3BD 10AWG 10.0 SW-10-8BD 6AWG SW-10-83BD 10AWG SW-12BD 6AWG SW-12-3BD 10AWG 11.5 SW-12-8BD 4AWG SW-12-83BD...
  • Page 5: Pre-Installation

    Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL PRE-INSTALLATION Verify correct model has been sized for the cubic feet and type of steam room using the GENERATOR SIZING GUIDE on Page 3. Check that the electrical power supply available is adequate for the voltage, amps and phase of the generator warning ELECTRICAL SHOCK HAZARD All installations and service must be performed by a qualifi...
  • Page 6: Installation

    24 Hr/7 Day Timer for TC-2 Water Supply Optional Line 60 Min Timer Power Box TC-2 & Power Disconnect STEAM-WHIRL 24 H Timer Blowdown Site Glass H-e-a-t Spa Kur Therapy Development Inc — Tel 707-942-6633 — Fax 707-942-0734 — www.h-e-a-t.com 6/20...
  • Page 7 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL PLUMBING IMPORTANT: All plumbing should be done by a qualifi ed plumber and must conform to all local and national plumbing codes. warning ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE MAKING ANY CONNECTIONS Use copper or brass fi...
  • Page 8: Plumbing Diagram

    Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL PLUMBING DIAGRAM Water Supply Line Classic Timer Pressure Gauge 24Hr Timer for Blowdown Site Glass H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 8/20...
  • Page 9 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRICAL IMPORTANT: All wiring should be done by a qualifi ed electrician and must conform to all local and national electrical codes. warning ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE MAKING ANY CONNECTIONS 1.
  • Page 10: Generator Diagram

    Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL GENERATOR DIAGRAM 4” 4½” 4” 21½” 20¼” 8¼” Water Supply Line 1/2” Copper Line, 1/2” NPT Female Thread Steam Output Line 3/4” Copper Line, 3/4” NPT Female Thread Pressure Relief Valve 3/4”...
  • Page 11 WL-2 Ground Ground CL-2 Lo sens Contactor PCB Controller Fuses 208/240V Timer 208/240 Load TIMER Ground Probe STEAM-WHIRL Classic Mechanical Timer Heater Tank Ground Ground Hi Limit Sensor Blow Down Valve H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 11/20...
  • Page 12 WL-2 Ground CL-2 Coil Lo sens Contactor PCB Controller Fuses 208/240V Timer 208/240 Load TIMER Ground Probe STEAM-WHIRL Classic Mechanical Timer Heater Tank Ground Ground Hi Limit Sensor Blow Down Valve H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 12/20...
  • Page 13 WL-2 Ground CL-2 Coil Lo sens Contactor PCB Controller Fuses 208/240V Timer 208/240 Load TIMER Ground Probe STEAM-WHIRL Classic Mechanical Timer Heater Tank Ground Ground Hi Limit Sensor Blow Down Valve H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 13/20...
  • Page 14 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL CLASSIC SERIES TIMER INSTALLATION Step 5 Step 4 2½” min Step 6 Step 2 Step 7 Turn power off at circuit breaker or fuse panel. Timer should be located on a wall outside the steam room, 5’ away. Run 14 AWG wire from back of timer 1-NO and 1-C to T1 &...
  • Page 15 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL TC-2 TEMPERATURE CONTROL to 60 MIN TIMER WIRING DIAGRAM TEMPERATURE CONTROL #90-4325 CLASSIC 60 MIN MECHANICAL TIMER PART NO: C9360NONC Stage TERMINAL BLOCK ON STEAM UNIT H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 15/20...
  • Page 16 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL TC-2 TEMPERATURE CONTROL TO TIME CLOCK WIRING DIAGRAM TEMPERATURE CONTROL #4320 TIMER 24HR 7DAY 208/240V TIMER, 208/240V LOAD Stage NC NO TIMER TERMIAL BLOCK ON STEAM UNIT H-e-a-t Spa Kur Therapy Development Inc — www.h-e-a-t.com 16/20...
  • Page 17: Maintenance

    Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL MAINTENANCE warning ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE PERFORMING ANY MAINTENANCE The steam generator is designed for unattended operation and requires little maintenance. Water Level Sensor Probe maintenance is as follows: •...
  • Page 18 Spa Kur Therapy Development INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL # ____________________________________________________________ DESCRIPTION ____________________________________________________________ SERIAL # ____________________________________________________________ WATER SENSOR PROBE MAINTENANCE SCHEDULE: 1st Cleaning Suggested: ______________________________________________________ 2nd Cleaning Check: ___________________________________________________________ 3rd Cleaning Check: ___________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________...
  • Page 19: Warranty

    WARRANTY Steam-Whirl Products warranties its products to be free of It is the responsibility of the user, installer or contractor to defects in workmanship and material, under normal use provide access for service and removal of the product, if and maintenance, for a period of (6) years from the date necessary.
  • Page 20 Heat Spa Kur Therapy Development Inc www.h-e-a-t.com — DrB @h-e-a-t.com...