Troubleshooting - Omron E5CC User Manual

Digital
Hide thumbs Also See for E5CC:
Table of Contents

Advertisement

A Appendices
A-5 Troubleshooting
Checking Problems
If the Digital Controller is not operating normally, check the following points before requesting repairs. If
the problem persists, contact your OMRON representative for details on returning the product.
Timing
Status
Turning
The TUNE indicator will
ON the
flash.
power for
the first
Temperature error is
time
large.
Input error (S.Err display)
Communications are not
possible.
During
Overshooting
operation
Undershooting
Hunting
Temperature is not rising
@
*
Refer to the E5
C Digital Temperature Controllers Communications Manual (Cat. No. H175) for details.
A - 14
Meaning
ST (self-tuning) is in
This is not a product fault.
progress (default setting:
The TUNE indicator flashes during self-tuning.
ON).
Input type mismatch
Check the sensor type and reset the input type correctly.
Thermometer is not
Check the thermometer installation location and polarity
installed properly.
and install correctly.
Non-recommended
Make sure that the connected device is not faulty.
adapter is being used.
ON/OFF control is
Select PID control and execute either ST (self-tuning) or
enabled (default: ON/OFF
AT (auto-tuning).
control selected).
When using self-tuning, turn ON the power supply to the
Digital Controller and load (heater, etc.) at the same time,
or turn ON the load power supply first. Accurate
self-tuning and optimum control will not be possible if the
power supply to the load is turned ON after turning ON the
power supply to the Digital Controller.
Control period is longer
Shorten the control period. A shorter control period
compared with the speed
improves control performance, but a cycle of 20 ms
of rise and fall in
minimum is recommended in consideration of the service
temperature.
life of the relays.
Unsuitable PID constant
Set appropriate PID constants using either of the following
methods.
• Execute AT (autotuning).
• Set PID constants individually using manual settings.
HS alarm operation fault
Use breeder resistance if the problem is due to leakage
current. Also investigate the errors detected by the HS
alarm function.
Specified operation is
Select either forward or reverse operation depending on
unsuitable for required
the required control. Reverse operation is used for heating
control (default: Reverse
operations.
operation).
Heater is burnt out or
Check whether heater burnout or deterioration have
deteriorated.
occurred. Also investigate the errors detected by the
heater burnout alarm.
Insufficient heater
Check whether the heater's heating capacity is sufficient.
capacity
Cooling system in
Check whether a cooling system is operating.
operation.
Peripheral devices have
Set the heating prevention temperature setting to a value
heat prevention device
higher than the set temperature of the Digital Controller.
operating.
Countermeasures
E5@C Digital Temperature Controllers User's Manual (H174)
Page
4-26
4-12
2-8, 2-12
*
4-24
4-15
4-24
4-41
4-15
4-39
---
---
---

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E5CC and is the answer not in the manual?

Questions and answers

Preston
January 23, 2025

how can I calibrate the temperature of the e5cc controller. Temp is reading about 10F high

1 comments:
Mr. Anderson
February 10, 2025

To calibrate the temperature on the Omron E5CC controller if it is reading 10°F high, follow these steps:

1. Check if Calibration is Necessary: The controller is factory-calibrated and usually does not need further calibration. User calibration should be done only if necessary.

2. Access Calibration Parameters: Use the controller’s settings to access the calibration parameters for temperature input.

3. Select the Input Type: Ensure the correct input type is selected (e.g., thermocouple, infrared sensor, resistance thermometer, current input, or voltage input).

4. Adjust Calibration: Modify the calibration settings to offset the 10°F error. Be cautious, as the calibration data will be overwritten, and default settings cannot be restored.

5. Confirm and Save: After making adjustments, save the calibration settings and verify the readings.

Be careful when performing user calibration, as Omron does not ensure the results of user-performed calibration.

This answer is automatically generated

Kuldeep Saxena
March 26, 2025

My omron e5cc controller set value 105 and show the actual temp 136 but it not oven in side temp.

User image 67e3f426a3ca2
1 comments:
Mr. Anderson
March 26, 2025

The Omron E5CC controller may be displaying an actual temperature of 136 instead of the set 105 due to several possible reasons:

1. Incorrect Sensor Type Setting – If the input type is not correctly set for the connected temperature sensor, the displayed temperature may be inaccurate. Ensure the correct sensor type is selected in the Initial Setting Level.

2. Sensor Malfunction or Disconnection – If the thermocouple or resistance thermometer is not properly connected or has failed, the controller may display incorrect readings. Verify the sensor connection and functionality.

3. Ambient Temperature Influence – The controller may be detecting the surrounding environment's heat. If the oven is not inside, ensure the sensor is measuring the correct area and is not exposed to external heat sources.

4. Control Mode and Hysteresis Settings – If the control mode or hysteresis values are not set appropriately, the controller might not regulate temperature correctly. Adjust these settings as needed.

5. Power Supply Issues – If the controller is being powered incorrectly, such as through a USB-Serial Conversion Cable instead of the specified terminals, it may not function properly. Ensure proper power supply.

Check these factors to identify and resolve the issue.

This answer is automatically generated

This manual is also suitable for:

E5acE5ec

Table of Contents

Save PDF