TAU STERIL Tau Clave 3000 Instructions For Use Manual

TAU STERIL Tau Clave 3000 Instructions For Use Manual

Fractionated vacuum

Advertisement

TAU STERIL s.n.c
Data: 30.03.15
Instructions for Use
Pag. 1 di 14
Via Gorizia, 6/a
TAU CLAVE 3000 Fractionated Vacuum
Rev. 3
N° 1
Fino Mornasco ( CO )
Instructions for Use
Tau Clave 3000 Fractionated
Vacuum
0426
DIRECTIVE 93/42 EEC and S.M.I.
MEDICAL DEVICES
1
This document may not be reproduced in partial form without the authorization of TAU STERIL.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tau Clave 3000 and is the answer not in the manual?

Questions and answers

PIOTR BIELIŃSKI
March 13, 2025

A 23- clock battery. What type of battery? How to replace it?

1 comments:
PIOTR BIELIŃSKI
April 11, 2025

@PIOTR BIELIŃSKI

Summary of Contents for TAU STERIL Tau Clave 3000

  • Page 1 Rev. 3 N° 1 Fino Mornasco ( CO ) Instructions for Use Tau Clave 3000 Fractionated Vacuum 0426 DIRECTIVE 93/42 EEC and S.M.I. MEDICAL DEVICES This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 2: Table Of Contents

    Transport and storage conditions Maintenance and cleaning Wire diagram Control panel Safety rules and precautions Decommissioning and scrapping of the appliance 10.1 Legend of symbols 10.2 This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 3: Tau Clave 3000 Fractionated Vacuum Rev

    Normative References The autoclave Tau Clave 3000 Fractionated Vacuum is conforming to the essential requirements of the Directives of the Council: Medical devices 93/42/CEE and S.M.I., class II b it is conforming besides to the national norms that are translated in...
  • Page 4: Door Opening And Closure

    Via Gorizia, 6/a TAU CLAVE 3000 Fractionated Vacuum Rev. 3 N° 1 Fino Mornasco ( CO ) Door opening and closure OPENING MOVEMENT CLOSING MOVEMENT This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 5: Installation

    Caution: It is recommended before using the autoclave with load (first load water happened) of looping "Unwrapped" (empty chamber without load) in order to sterilize the chamber. This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 6: Characteristics

    0.20 / 2.25 Bar WARNINGS: During the sterilization process TAU STERIL always recommended to insert in the sterilization chamber of the autoclave (with the material to be sterilized) an indicator of detection of the sterilization process (in compliance with current regulations).
  • Page 7: General Information

    = drying FILL = filling (dose water) VACUUM = vacuum HEATING = heater STERILIZE = sterilization = drying = end of the cycle PRINT = print This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 8: Alarms Visualization Modes

    * = Repeat cycle, the material to be sterilized is not sterile. If the problem persists, contact manufacturer. N.B: A00, A01, A02 do not cause (in the presence of printer) no print activity. This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 9: Operating Instructions

    70 degrees C °. This allows to obtain materials perfectly dry. The machine can still be open at any time by opening the door (see movement opening - closing the door 2.1 p. 3). This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 10: Transport And Storage Conditions

    Check monthly (or even if you move the device) the electric power cable is intact and in good condition. In case of malfunction contact the manufacturer. For repairs, it is recommended to make the autoclave to the manufacturer, using the original packaging This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 11 IMPORTANT: when you place the tube with the new filter, make sure that it is well established, keeping a distance from the probe equal to 2.5 cm. This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 12: Wire Diagram

    6 = Selection Program 7 = START / STOP 8 = Led Alarms 9 = Fuses 10 = Switch General 11 = Led Operation 12 = Led Program This document may not be reproduced in partial form without the authorization of TAU STERIL.
  • Page 13: Safety Rules And Precautions

    10.1 Decommissioning and scrapping Device The autoclave Tau Clave 3000 Fractionated Vacuum is constructed of ferrous materials, electronic components and plastics. If the appliance is no longer repairable and running, separate the various components according to the material of which they consist, in order to simplify a possible re-use or disposal differentiated.
  • Page 14: Pag. 2 Di

    WARNING: DANGER BURNS CAUTION: RISK OF ELECTRIC SHOCK WARNING: USE GLOVES FOR HAND PROTECTION PRODUCT NOT COMPARABLE TO MUNICIPAL WASTE. FOLLOW THE RULES FOR MUNICIPAL DISPOSAL This document may not be reproduced in partial form without the authorization of TAU STERIL.