Ack
Header
Command
ID
Data length
0xAA
0xFF
3
"Input Source": An input source code to be set on a product.
•
Nak
Header
Command
ID
Data length
0xAA
0xFF
3
"ERR" : A code showing what error has occurred.
Ack/Nak
r-CMD
Val1
Checksum
'A'
0x14
"Input
Source"
Ack/Nak
r-CMD
Val1
Checksum
'N'
0x14
"ERR"
Safety Lock
•
Function
PC can be used to turn the
Safety Lock On
This control is available regardless of whether or not the power is turned on.
•
Viewing the safety lock state (Get Safety Lock Status)
Header
Command
ID
0xAA
0x5D
•
Enabling or disabling safety lock (Set Safety Lock Enable / Disable)
Header
Command
ID
0xAA
0x5D
"Safety Lock": Safety lock code to be set on a product
1: ON
0: OFF
•
Ack
Header
Command
ID
Data
length
0xAA
0xFF
3
"Safety Lock": Safety lock code to be set on a product
•
Nak
Header
Command
ID
Data
length
0xAA
0xFF
3
"ERR": A code showing what error has occurred
function on or off on a product.
Data length
Checksum
0
Data length
Data
Checksum
1
"Safety Lock"
Ack/Nak
r-CMD
Val1
'A'
0x5D
"Safety Lock"
Ack/Nak
r-CMD
Val1
'N'
0x5D
"ERR"
Checksum
Checksum
22