Advertisement

ASTROAI USER MANUAL
TRUE RMS DIGITAL MULTIMETER
Thank you for purchasing the True RMS 6000 Count Digital Multimeter from AstroAI. The
AstroAI True RMS Digital Multimeter is designed to be safely and accurately used by
professionals in a commercial setting or weekend DYer's that need a little more utility from their
standard digital multimeter. This manual provides all safety information, operation instruction,
Specifications, and maintenance for the meter. The instrument performs AC/DC Voltage, AC/DC
Current, Resistance, Audible Continuity, Diode, hFE, Frequency, Capacitance, and
Temperature Testing. Thank you again for choosing AstroAI, if you have any questions or
concerns regarding your product, please contact us at support@astroai.com.
NOTE: Fully read and understand this manual before using this Digital Multimeter.
WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage to
the Meter or to the equipment being tested, adhere to the following rules:
● Before using the Meter, inspect the exterior casing. Do not use the Meter if it is damaged
or if all or part of the exterior casing is removed. Look for cracks or missing plastic. Pay
special attention to the insulation around the connectors.
● Inspect the test leads for damaged insulation or exposed metal. Check the test leads for
continuity.
● Do not apply more than the rated voltage, as marked on the Meter, between the
terminals or between any terminal and grounding.
● The manual rotary switch should be placed in the correct position before measurement
and should NOT be moved during measurement to prevent damage to the Meter.
● When the Meter is working at an effective voltage over 60V in DC or 30V rms in AC,
special care should be taken because there is a danger of electric shock.
● Use the proper terminals, function, and range for your measurements.
● Do not use or store the Meter in a high-temperature environment, do not expose to high
levels of humidity, or near strong magnetic fields. The performance of the Meter may
deteriorate after dampening.
● When using the test leads, keep your fingers behind the finger guards.
● Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, diodes or hFE.
● Replace the battery as soon as the battery indicator appears. With a low battery, the
Meter might produce false readings that can lead to electric shock and personal injury.
● Remove the connection between the testing leads and the circuit being tested, and turn
the Meter power off before opening the Meter case.
● When servicing the Meter, use only the same model number or identical electrical
specifications replacement parts.
● The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter
and any accident.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the True RMS 6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AstroAI True RMS 6000

  • Page 1 ASTROAI USER MANUAL TRUE RMS DIGITAL MULTIMETER Thank you for purchasing the True RMS 6000 Count Digital Multimeter from AstroAI. The AstroAI True RMS Digital Multimeter is designed to be safely and accurately used by professionals in a commercial setting or weekend DYer’s that need a little more utility from their standard digital multimeter.
  • Page 2 ● Clean using a soft cloth and mild detergent for the surface of the Meter. Do not use abrasive materials or solvents to prevent the surface of the Meter from corrosion and damage. ● Turn the Meter off when not in use and take out the battery when it is not going to be used for an extended period of time.
  • Page 3 Operating Environment 32°F~104°F (0°C~40°C); <80% RH Storage Temperature 14°F~122°F (-10°C~50°C); <85% RH Power 1 x 9V 6F22 Battery Included Dimensions 190x90x35mm Weight Approx 357g Temperature Test Transistor Test Diode Test Continuity Test External Current Test Capacitance Frequency Safety/Compliances EN 61010-1 CAT III 600V, CATII 1000V DC Voltage 600mV6 ±(0.8%+5), V/60V/600V ±(0.8%+3), 1000V ±(1%+5) AC Voltage...
  • Page 4 MULTIMETER DIAGRAM 1. Magnetic Hanger 2. LCD Screen 3. Function Buttons 4. Rotary Function Switch 5. 10A Terminal 6. μA/mA Terminal 7. COM Terminal 8. INPUT Terminal 9. Silicone Sleeve 10. Multi-Function Socket...
  • Page 5 LCD SCREEN DIAGRAM Duty Cycle Fahrenheit Temperature ℉ Celsius Temperature ℃ Transistor hFE Continuity Test Diode Test External Current Test (Clamp) AUTO Autorange Mode Automatic Power-Off Data Hold Maximum Reading Minimum Reading Negative Reading Low Battery, Replace Immediately Relative Mode GETTING TO KNOW YOUR DEVICE Select Button When using the rotary switch to select a multimeter function, use the Select Button to further...
  • Page 6 Max/Min Button When taking a measurement, press this button once to enter “Max Mode”. In this mode, the multimeter will capture the highest reading it records. Press this button again to enter “Min Mode” which will capture the lowest reading it records. Press and hold this button to exit the Max/Min Modes.
  • Page 7 DC Voltage (Auto ranging) Range Resolution Accuracy 600mV 0.1mV ±(0.8% of rdg + 5dgts) ±(0.8% of rdg + 3dgts) 10mV 600V 100mV 1000V ±(1.0% of rdg + 5dgts) Input Impedance: 10MΩ Overload Protection: 600V DC/AC RMS Max. Input voltage: 600V DC Measure DCV 1000V under CATII AC Voltage (Auto ranging) Range...
  • Page 8 Temperature Range Resolution Accuracy -40~1370°C 1°C -40°C~150°C:±(1% + 4) -40°F~302°F ±(5% + 4) 1°F 302°F~2000°F ±(2.5% + 3) Overload Protection: F0.4A/600V Fuse DC Current Range Resolution Accuracy 600µA 0.1µA 6000µA 1µA ±(0.8% of rdg + 5dgts) 60mA 10µA 600mA 100µA ±(1.5% of rdg + 3dgts) 10mA Overload Protection:...
  • Page 9 Transistor hFE Test (Connect Adapter ) Range Test Current Test Voltage PNP & NPN 0~1000 Ib≈2µA Vce≈1V AC Current Range Resolution Accuracy 600µA 0.1µA 6000µA 1µA ±(1.5% of rdg +8dgts) 60mA 10µA 600mA 100µA 100mA ±(2.0% of rdg +10dgts) Overload Protection: ●...
  • Page 10 Resistance (Auto Ranging) Range Resolution Accuracy 600Ω 0.1Ω 6KΩ 1Ω 60KΩ 10Ω ±(1.5% of rdg + 3dgts) 600KΩ 100Ω 6MΩ 1KΩ 60MΩ 10KΩ ±(1.5% of rdg + 5dgts) Open Circuit Voltage: about 0.25V Overload Protection: 250V DC/AC RMS 600A AC current through a clamp (DT3303 optional) 600A 1mV/10A ±(2.5%+10)
  • Page 11 Capacitance Range Resolution Accuracy 60nF 10pF 600nF 100pF ±(8% of rdg + 5dgts) 60uF 10nF 600uF 100nF 20uF 10uF Overload Protection: F0.4A/600V fuse Open circuit voltage: about 0.5V Frequency (Auto Ranging) Range Accuracy 0~60MHz ±(1.0% + 5) Overload Protection: 250V DC/AC RMS OPERATING INSTRUCTIONS Voltage Measurement 1.
  • Page 12 b. In manual range, when the multimeter shows “OL” or Over Range, you must select a higher range in order to get results. c. To avoid damage to the meter, do not measure voltage exceeding 600V DC or 600V AC CATIII.
  • Page 13 Diode Test 1. Connect the black test lead to the “COM” jack and the red test lead to the “INPUT ” jack. 2. Set the function switch to “ ” range. 3. Press the “Select” Button to select continuity measurement mode, and the symbol “ ”...
  • Page 14 b. Set the function switch to “ ” range. c. Connect the test leads to the capacitor to be measured. Be sure to be aware of the polarity of the connection. Note: a. When the capacitance under measure is more than 600uF, it needs at least 10 seconds to make readings stable.
  • Page 15 1 Year Warranty Limited Warranty From AstroAI Each AstroAI Digital Multimeter will be free from defects in material and workmanship. This warranty does not cover fuses, disposable batteries and damage from neglect, misuse, contamination, alteration, accident, or abnormal conditions of operation or handling, including overvoltage failures caused by use outside the Multimeter’s specified rating, or normal wear and...

This manual is also suitable for:

Wh5000a

Table of Contents

Save PDF