Brilliantlight Activation; Brilliantlight Assembly Removal; Figure 010-6: Brilliantlight Circuit Board And Plug - Miele G 4205 Technical Information

G 5 series futura dishwashers
Hide thumbs Also See for G 4205:
Table of Contents

Advertisement

G 5xxx
closed and opened sufficiently such that the light is switched on and off.
4.5

BrilliantLight Activation

1. Half-open the dishwasher door and quickly partially close and open it
three times.
2. Check the function for correct operation and repeat the process, if
necessary.
4.6

BrilliantLight Assembly Removal

Note:
The BrilliantLight LEDs must always be replaced in pairs in order to ensure
even lighting.
Old parts must not be re-used. If, for example, the lens with seal is
replaced, the circuit board must also be replaced.
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. If removing the side lighting assemblies, remove both side panels (Section
010-4.1). If removing the top lighting assemblies, move the top insulating
mat out of the way. Continue as follows for all assemblies.
4. Disconnect the wiring harness, Figure 010-6, Item A.
5. Unclip the circuit board by pressing its retainers to the sides with a small
flathead screwdriver, Figure 010-6, Item B.
6. Remove the circuit board.

Figure 010-6: BrilliantLight Circuit Board and Plug

7. Press the lens retainers to the sides using a small flathead screwdriver,
Figure 010-7, Item A.
8. Remove the lens with seal.
37