7.3. Daily update frame

This frame is sent daily at 1 AM. It contains a little summary. This frame can be deactivated using the Plug & Sense! Smart Parking
USB Programmer or via radio, with the response given by the Remote Manager, hosted in the cloud.
Byte
0
Basic data
1
Frame counter
2
Sensor measurements MSB
3
Sensor measurements LSB
4
Sigfox transmissions MSB
5
Sigfox transmissions LSB
6
LoRaWAN transmissions MSB
7
LoRaWAN transmissions LSB
8
Resets
9
Config_id
10-11
Reserved
Figure : Daily update frame structure
This frame is sent daily at 1 AM. It contains a little summary. This frame can be deactivated using the Plug & Sense! Smart Parking
USB Programmer or via radio, with the Remote Manager, setting to 0 the enable/disable daily frame bit.
The daily update frame is very special because the node waits for a response after it is sent. This response is useful for reconfiguring
the node "over the air", without physical access. Also, a second use of this response frame is to synchronize the node's internal
clock, thanks to a timestamp. This response can be configurated using the remote PHP.
Name
Detailed description in section "Frame"
Detailed description in section "Frame"
Unsigned 16 bit counter. It stores the times that the sensor is used in
the last 24 hours.
Unsigned 16 bit counter. It stores the times that Sigfox radio is used in
the last 24 hours.
Unsigned 16 bit counter. It stores the times that LoRaWAN radio is
used in the last 24 hours.
Number of resets generated in the last 24 hours
Value of the configuration version loaded into the node
Reserved bytes. Do not consider.