When installing or servicing this stove, care should OMPETENT ERSONS CHEME be taken to avoid the possibility of personal injury. Parkray Ltd recommend that this stove is installed by a member of an accredited competent persons ODIFICATION scheme e.g. HETAS. No unauthorized modification of this appliance should be carried out.
Move furniture, ornaments etc away long periods without first adjusting the controls to Place a fireguard in front of stove a safe setting. Careful air supply control should be Check the chimney breast for signs of excessive exercised at all times.
Building Regulations Approved Document J or a installation. Parkray Ltd cannot be held twin-walled insulated stainless steel flue to BS EN responsible for any fault arising through incorrect 1856 can be used.
Parkray Ltd cannot be held responsible for any Within 2300mm of At least 600mm above any part fault arising through incorrect use or installation. an adjoining or of the adjacent building within...
Page 7
A combustible fire surround with a depth of up to 2. Remove the fuel retainer by lifting off of its 100mm requires a minimum clearance of 75mm supports and remove from firebox. from the side of the stove. For combustible fire surrounds with a depth in excess of 100mm this clearance must be increased to 200mm.
Page 8
4. Remove the bricks by sliding forward so they are clear of their supports and tilting the bottom edge into the fire box. 6. Remove the baffle by sliding it forward until it reaches its stop. Then lift and slide forward until clear of its supports and lower into the firebox.
Installing the Stove installation of the heating and hot water system. 1. Check positions of pipe connections. Parkray Ltd cannot accept responsibility for any 2. Make suitable access holes so you can access consequential loss, however caused, due to under...
If a common flow and return is used, these should If connecting to an existing masonry chimney it is also be taken from diagonally opposite sides of recommended that a flue forming pipe (short the boiler, and plugs inserted into the sockets not length of flue pipe) is used and the void between used.
Page 11
Four Tapping System Time Switch Room Thermostat High Limit Thermostat 90°C Circulating Pump Low Limit Thermostat (45°C) Drain Cock Two Tapping System Time Switch Room Thermostat High Limit Thermostat 90°C Circulating Pump Drain Cock Low Limit Thermostat (45°C) Injector Tee Wiring Diagram for general guidance only All electrical work must be carried out by a competent electrician in accordance with the rules in force and the...
OCOMOTIVE RATE etc, as these could be damaged and could Your Parkray Ltd Stove is fitted with a locomotive potentially create a fire hazard (For more type grate. So that de-ashing can be carried out information read the ‘Material Clearance’ section cleanly and easily, it is riddled from the outside of of these installation instructions).
Page 13
AFFLE PERATION IGHTING Your Parkray Ltd Stove if fitted with a sliding We recommend that you have two or three small baffle. The baffle needs to be slid into its open fires before you operate your stove to its position when lighting and re-fuelling your stove.
ECOMMENDED UELS or fly ash that could lead to blocked flueways and dangerous fume emission. Parkray Ltd recommends that approved smokeless fuels are burnt in this appliance. If the baffle is removed the chimney/flueway can be swept through the appliance.
Rope - Check the rope around the door. If rope is Trouble Shooting becoming detached, use Parkray Ltd rope glue to reattach it. If the rope is in a poor condition, a Check that – replacement rope kit may be ordered from the Parkray Ltd spares range.
Spares Information INGLE PARES SINGLE DOOR HCE09/008 DOOR HANDLE DOOR GLASS AVA08/029MB HCE09/102 ROPE SEALING KIT DOOR CATCH SCPCB900SDRSK ASSEMBLY TDI05/ARRT/011MB GLASS CLIP HHR08/046 GLASS GASKET HCE09/101 GLASS CLIP SCREW FSJM05008SS JINCHW09 Rev A 12/05/14...
Need help?
Do you have a question about the Inset Chevin 20B and is the answer not in the manual?
Questions and answers