&RPPLVVLRQLQJ
6. Control the PO via menu item 9DULDEOH ! (QDEOH FRQWURO YDOXHV . "Enable PO"
mode remains active until switched off again via 9DULDEOH ! (QDEOH 32 .
"Enable PO" is also terminated when the connection to the PG goes down.
7. Return to step 4 if you want to specify new values.
1RWH
For example, a message pops up to indicate CPU mode transition from STOP
to RUN or START-UP.
A message also pops up indicating that the "Enable PO" function is selected
while the CPU is in RUN mode.

&RPPLVVLRQLQJ 352),%86 '3

&RPPLVVLRQLQJ 352),%86 '3
5HTXLUHPHQWV
Requirement for commissioning a PROFIBUS DP network is:
• A PROFIBUS DP network has been created.
• In 67(3 , you have configured the PROFIBUS DP network and you have
assigned all network nodes a PROFIBUS DP address and memory area (see
the Manual 6,0$7,& 67(3  9[ &RQILJXULQJ KDUGZDUH DQG FRQQHFWLRQV ZLWK
67(3  9[).
• Note that you must also set address switches in some of the DP slaves (see the
description of the relevant DP slave).
• Software requirements are shown in the table below, depending on the CPU:
Table 9-6
&38
313C-2DP
314C-2DP
315-2 DP
317-2 DP
9-22

Software requirements

2UGHU 1R
6ES/313-6CE00-0AB0
6ES7314-6CF00-0AB0
6ES7315-2AG10-0AB0
6ES7317-2EJ10-0AB0
S7-300 Automation System, Hardware and Installation: CPU 31xC and CPU 31x
6RIWZDUH UHTXLUHG
67(3  V 5.1 or later + SP 4
&20 352),%86 V 5.0 or later
67(3  V 5.1 or later + SP 4
67(3  V 5.2 + SP 1 or later
A5E00105492-03