Page 2
WIRING WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property.
PUMP STRAINER BASKET This unit, sometimes referred to as the “Hair and Lint Pot”, is the unit in front of the volute. The lint pot must be installed using only teflon tape on the threads. Do not use liquid chemical thread sealant. The basket inside the chamber must be kept clean of leaves and debris at all times. View basket through the “See Through Lid”...
Page 4
WINTERIZING CARE OF ELECTRIC MOTOR PROTECT FROM HEAT If the air temperature drops below 35º F. the water in the pump can freeze and cause damage. Freeze damage is not warrantable. 1. Shade the motor from the sun. 2. Any enclosure must be well ventilated to prevent overheating. 3.
PUMP DISASSEMBLY CAUTION: Be sure not to scratch or mar the polished seal faces. Seal will leak if faces are damaged. All moving parts are located in rear sub-assembly of this pump. 5. Remove the diffuser. Tools required: 6. Hold the impeller securely in place and remove the impeller lock •...
Page 6
SMF PUMP REPLACEMENT PARTS FIGURE 3 Part No. Qty Description Part No. Qty Description 3310330 Motor, 48-FRAME SQ FLG 3/4HP 115/230V 60HZ 319-1420 Diffuser Plate 819-0035 715-1200 3/8” Quarter Slot Plug (Sd Wet End) Bolt .375-16 X .875 Long 672-1350 Neoprene Motor Support Strip 805-0014 O-Ring, -014...