Owing to product upgrading or other reasons, information in this manual is subject to change. Hangzhou DPtech Technologies Co., Ltd. has the right to modify the content in this manual, as it is a user guides, Hangzhou DPtech Technologies Co., Ltd. made every effort in the preparation of this document to...
Wide Area Networks (WANs), Metropolitan Area Networks (MANs) as a convergence layer device. Product features The DPtech LSW6600 is available in five models, including: LSW6602-24GT4XGS ...
Page 6
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Item LSW6602-24GT4XGS LSW6602-48GT4XGS 4*10GBase-R Ethernet optical (RJ45) port(SFP+) 4*10GBase-R Ethernet 1*Ethernet management port optical port (SFP+) MGMT 1*Ethernet management port MGMT Rated voltage range: Input Rated voltage range: 100V~ voltage 100V~240V AC, 50/60Hz...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Item LSW6600-48XGS4QXP LSW6600-8GT24XGS Power supply maximum 375W 150W power Heat dissipation system Use 2 fan frame to dissipate Use 2 fan frame to heat dissipate heat Working environment 0℃~45℃ temperature Working altitude 10%~95% Front view 1.3.1...
Page 8
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-2 Front view of LSW6602-24GT4XGS (1) (2) (8) (9) (10) (13)(12) (11) Status Description (1)10/100/1000M Ethernet Steady on Means the GE0 electrical port is electrical interface connected. LED(0)( Green) Blink Means the GE0 electrical port is sending and receiving data.
Page 9
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Status Description Steady on Means the inserted module 2 is working normally. (12)Power LED(PWR Steady on Means the power supply 1 is working (Green) normally. Steady off Means the power supply 1 isn’t power-up or the power supply isn’t...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 1.3.2 LSW6602-48GT4XGS product appearance Front view (1) (2) (3) (4) (5) (6)(7) (13) (12) (11)(10) (1)10/100/1000M Ethernet electrical (2)10/100/1000M Ethernet electrical interface LED (0) interface (0) (3) Ethernet management port LED (4) Ethernet management port MGMT...
Page 11
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Status Description MGMT(Green) Blink Means the management port (MGMT) is sending and receiving data. Steady off Means the management port (MGMT) is disconnected. (6)System Steady on Means the system is working normally and LED(RUN)(Green) is in active status.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Rear view Figure 1-5 Rear view of LSW6602-48GT4XGS (1) AC power socket (2) AC power socket (3) Grounding terminal (4) SLOT(2 slots can be inserted) 1.3.3 LSW6600-8GT24XGS product appearance 1.3.3.1 Front view (1)(2)
Page 13
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-6 Front view of LSW6600-8GT24XGS (8) (9) (11)(10) Status Description (2) 10G Ethernet optical port Steady on Means the 10GE optical port 0 is LED(0) (Green) connected. Blink Means the 10GE optical port 0 is sending and receiving data.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 1.3.3.2 Rear view Figure 1-7 Rear view of LSW6600-8GT24XGS (1)AAC power socket (2) AC power socket (3) Grounding terminal 1.3.4 LSW6600-48XGS4QXP product appearance 1.3.4.1 Front view (6)(5) (1) 10G Ethernet optical port(0) (2) 40G Ethernet optical port (0)
Page 15
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-8 LSW6600-48XGS4QXP front view (6)(5) Status Description Steady Means the system is working normally and is in active status. Blink Means the system is working normally and is (1Hz) in backup status.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-11 Diagram for Ethernet cable Because of different usage, Ethernet cable can be classified as standard cable (straight cable) and cross cable: Standard cable: also is called straight cable. The sequences of the twisted pairs crimped in the RJ45 connectors at both ends are the same.
Page 20
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Properties Description Fiber Mode Output power RX Sensitivity Light saturation Interface standard +3.0 ≤-5.4(each lane) -8.0~+2.4 Central wavelength 850nm Central wavelength 50/125μm Mode 2000 4700 bandwidth(MHz*km) Max transmission 100M 150M distance Working mode 1000Mbps, full-duplex mode 1.4.3.2...
Page 21
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-12 LC connector appearance Figure 1-13 SC connector appearance When you optical fiber to connect network device, please make sure the optical fiber connector is correspond to optical fiber. Before connecting optical fiber, please make sure that the transceiver power of local device isn’t exceeding the upper limit of optical module.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 1-14 Diagram of optical module 1.4.4 Combo port A SFP port and a 10/100/1000Base-T auto-negotiation port form the Combo port. When two Combo ports form at the same the time, you only can use one.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Installation preparation To avoid possible bodily injury and equipment damage, read all safety recommendations carefully before installation, pay attention to the installation, operation and maintenance precautions. Note that the recommendations do not cover every possible hazardous condition.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 2.2.1 Temperature/humidity requirement The equipment room must maintain adequate temperature and humidity so that it can ensure the device working normally and extend service life. Long-lasting high humidity is prone to cause bad insulation and even electricity creepage.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Table 2-2 Dust limit in the equipment room Substance Unit Content Dust Particles/m³ ≤3× (No visible dust on the table top for three days) Note: Diameter of a dust particle ≥ 5 μ m...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 inductance coupling, electromagnetic wave radiation, and common impedance (including the grounding system) coupling. To resist the interference, make sure to: The alternating power supply system is TN system. Adopt single-phase three wire socket with protection ground wire to filter electricity power interference by the device filter circuit.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 You should bundle the cables if there are too many cables and according to different types to bundle the cables (such as power line, interface wire, ground wire) The cables should be labeled for your troubleshoot or dismount the device.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Device installation Installation procedure Figure 3-1 Device installation procedure Start Mount the switch on a Install switch to a 19-inch workbench rack Connect ground wire Connect power cable Connect the switch to a...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Before installation You have read Chapter 2 carefully. The requirements in Chapter 2 are satisfied Power off your device before installation. Installing the switch to a place You can adopt the following 2 methods to install the switch: ...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 3-2 Install the switch to a workbench 3.3.2 Install the switch to a cabinet 3.3.2.1 Mounting ears to your switch Figure 3-3 Mounting ears to your switch 3.3.2.2 Install the switch to a cabinet Figure 3-4 Install the switch to a cabinet (Omit cabinet)...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 3.3.2.3 Fixing a switch Figure 3-5 Fixing a switch Grounding the switch For the safety of operators and equipment (anti-thunder, tamper-proof), securely ground the swi Make sure the anti-interference between the switch chassis and the ground is less than 5 ohm.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Fasten the grounding screw, which is attached with the OT terminal of the grounding cable, into the grounding screw hole with a screwdriver. Connect the other end of the cable to the ground.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 The serial ports on PCs do not support hot swapping. In case the switch is powered on, when connecting a PC to the switch, first connect the DB-9 connector of the console cable to the PC and then the RJ-45 connector to the switch;...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 3.6.2 Connecting redundancy power cable Figure 3-8 Power socket (1) (2) (3) (1) Power positive (+) (2) Power NC (3) Power negative (-) The device provides a DC-12V power socket, each pin of it are shown in above figure.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Starting up the Switch and Upgrading Software Starting up the Switch at the Initial Boot 4.1.1 Setting up a Configuration Environment 4.1.1.1 Connecting the Switch to the Terminal PC Connect the RJ-45 connector of the console cable to the console port on the...
Page 38
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 4-2 Setting up a new connection On the connection description window, you enter a name and click <OK>. as shown in Figure 4-3 displays. Then select the serial port to be used from the <Connect Using>...
Page 39
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Click <OK>. The Port Settings tab, shown in Table 4-1, appears and you can set serial port parameters. Set the following parameters: Table 4-1 Attributes of configure serial port Properties Value Baud rate...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 4-6 Settings tab 4.1.2 Booting the Switch 4.1.2.1 Verifying installation before power-up Before powering up the switch, check that: Both the power cord and the grounding wire are correctly connected. ...
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 4.1.2.3 Verifying Installation before Power-up Please do the followings after the device is powered on: Verify whether the ventilation system works normally. Inspection method: when you start the device, you can heart the fan whirling sound, and you can feel air flow around air ventilation hole.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Robo Management on SPI channel 0 Robo device id is 0x0 boot extend... ********************************************************* ConBoot, extend Version 3.2.0 ********************************************************* …… extend main start at 0x879541b4 …… PCB Version :* CPLD init successfully! ST Serial flash at 0xbfc00000 size 4096KB!
Page 44
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Figure 4-7. Both of default username and password are “admin_default”, click <Login> button to enter the Web management interface. Figure 4-7 Web management interface We do not suggest you that use both of the http and https protocol to login on the same PC.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 Troubleshooting Power system failure Fault phenomenon The PWR LED on main control board front panel is OFF. Troubleshooting The PWR LED on main control board front panel is used for indicating power module operation status.
DPtech LSW6600 Ethernet Switch Installation Manual V1.3 5.2.1 No terminal display Fault phenomenon If terminal display is garbled after you power on the device. Troubleshooting Please check the following: (1) The power supply system is operating properly. (2) The console cable has been connected to the console port of the device.