AQUA IONIC
USER'S AND MAINTENANCE
MANUAL
Aqua Ionic
-
1 di 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUA IONIC and is the answer not in the manual?

Questions and answers

Summary of Contents for SIATA AQUA IONIC

  • Page 1 Distributed b Distributed by: S.I.A.T.A Asia Pacific Pte Ltd 37 Tannery Lane #06-08 Tannery House Singapore 347790 Tel: +65 6741 2994 • Fax: +65 6741 2995 www.siata.com.sg AQUA IONIC USER’S AND MAINTENANCE MANUAL Aqua Ionic 1 di 24...
  • Page 2 EN 60742 Directions concerning isolation and security trasformers. S.I.A.T.A. S.r.l. has a quality system in accordance with the requirements of ISO 9001/ UNI EN ISO 9001-ed.1994 (Certificate n° 95.022 SGS ICS) Managing Director LUIGI FERRALI TEN0044.doc Aqua Ionic 2 di 24...
  • Page 3: Table Of Contents

    6.7 – Installing the probe......................16 6.8 – Connections .......................... 17 6.8.1 – Connection of this version to 3 DIN sockets ..............18 7 – TROUBLESHOOTING ..................19 8 – SPARE PARTS ....................21 Aqua Ionic 3 di 24...
  • Page 4: General Characteristics

    Aqua Ionic, as well as all the other SIATA controllers, is compliant with the EEC Directives and is built in the SIATA factory in Montespertoli, Florence (Italy) working with the Quality System certified according to the following standard ISO 9001 / UNI EN ISO 9001.
  • Page 5 AUTO VOLUME It is on when the regeneration must start because of exhausted volume. MANUAL It is on when the regeneration must not start automatically. INT. ALARM It is on when regeneration is not successful. Aqua Ionic 5 di 24...
  • Page 6 Placed below the 6 keys, in the middle between Advance and Volume/Clock, it allows to start a test regeneration. When pressed during some programming HIDDEN KEY phases, it zeroes the digit blinking on the display. Aqua Ionic 6 di 24...
  • Page 7: Code Meaning

    Controller version, assigned by the Technical Office for customizations (05 = standard). Typology of the electric connections (02 = DIN sockets). Number of drivers (7 = 7 drivers). Family to which the controller belongs (AI = Aqua Ionic). Aqua Ionic 7 di 24...
  • Page 8: General Information

    The controller is supplied by a 230 / 12 Vac transformer. Upon request, other types of transformer are available (Es. 115 / 12 Vac – 60 Hz). The right hand side of the case is opened where the DIN sockets are placed (Fig. 9). Fig. 3 Fig. 4 Aqua Ionic 8 di 24...
  • Page 9: Maintenance

     an air humidification system (with water or proper silicone lubricant) is mounted on the air line, in order to prevent the driver internal seals from getting dry; SIATA always recommends to supply the drivers with water. In this case it is necessary to use an input filter to avoid impurities.
  • Page 10: Instructions For Use

    6 – INSTRUCTIONS FOR USE 6.1 – Powering on Aqua Ionic is not provided with power switches. Powering on is obtained by connecting the power transformer to the outlet. 6.2 – Working After powering on, the display placed on the front panel will display the conductivity value read by the probe.
  • Page 11: Auto Set Point

    (see previous point). 6.2.1 – Auto Set Point When Aqua Ionic is programmed in the Auto Set Point mode (this condition must be confirmed by the illumination of the corresponding LED on the panel), there is a comparison between the conductivity value and the programmed set point value (steps 1 and 2 in tab.
  • Page 12: Auto Volume

    6.2.3 – Auto Set Point + Auto Volume When Aqua Ionic is programmed in the Auto Set Point + Auto Volume mode (both LEDs on the panel are on), both checks indicated in par. 6.2.1 and 6.2.2 are carried out. The regeneration is activated by the check which as first satisfies the conditions required for the cycle to be started.
  • Page 13: Auto Volume + Manual

    6.2.6 – Auto Volume + Manual When Aqua Ionic is programmed in the Auto Volume + Manual mode (this condition must be confirmed by the illumination of both LEDs on the panel), the regeneration can be activated only using the Manual Regen key on the panel. When the volume exhausts, the Alarm output on the DIN 360°...
  • Page 14: Programming

    6.4 – Programming Aqua Ionic is programmed using the Program Mode key, and the values can be modified using the Advance key. Proceed as follows to perform programming: Programming table (Tab. 3)  Step Display Meaning 0 1 0 0 Set point value. The digits on the right-hand side blink.
  • Page 15: Starting Operations

    This is possible ONLY when the controller “senses” that the cam is correctly positioned at the stop. In order to perform a few tests before installation, it is necessary to connect Aqua Ionic to its case in order that the limit switch input be correctly closed.
  • Page 16: Installing The Probe

    6.7 – Installing the probe. The conductivity probe is the most important element of Aqua Ionic and its installation must be performed with the highest care. A screened cable is always the best choice to connect the controller to the probe. This choice is compulsory when the distance between the controller and the probe is over 2 meters and/or when the environment where the controller is being installed is subject to strong electromagnetic interferences.
  • Page 17: Connections

    6.8 – Connections Fig. 6 Fig. 6 shows the correct usage of the signals issued by Aqua Ionic in the Open Collector mode. The relay indicated in the figure must be connected between the terminal of the +12 Vdc and the terminal of the signal concerned (in the example it is the cycle-end impulse).
  • Page 18: Connection Of This Version To 3 Din Sockets

    Output of the Set Point signal in the Open Collector mode. DIN C, 3 – 4 Output of the Impulse During Regeneration signal in the Open Collector mode. DIN C, 5 – 4 Output of the Alarm signal in the Open Collector mode. Aqua Ionic 18 di 24...
  • Page 19: Troubleshooting

    Replacing the electronic board may be already a precious help to identify the real cause of the defect. If our suggestions are not sufficient to solve your problems, please contact the SIATA assistance service. DEFECT...
  • Page 20 Fig. 10 Seeger Fig. 10 clearly shows the micro switch, its block and command mechanical details, and the terminals for connection to the controller. Aqua Ionic 20 di 24...
  • Page 21: Spare Parts

    3. Second microswitch. Item 19 in both attachments shows the ring controlling a second microswitch during the cam rotation. Please contact the SIATA sales department for further information about the performances that can be obtained with such a modification.
  • Page 22 Micro-switch wire External cam kit 2221-2* Micro-switch blocking plate 88-A Microswitch 92-F Microswitch holder Aqua Ionic electronic board kit 892-K Cover blocking screw Timer case transparent cover Stop ring on power takeoff 84-AS Black cable lock 90-XP Turbine sensor cable, 50 cm length...
  • Page 23 Aqua Ionic 23 di 24...
  • Page 24 Distributed b Distributed by: S.I.A.T.A Asia Pacific Pte Ltd 37 Tannery Lane #06-08 Tannery House Singapore 347790 Tel: +65 6741 2994 • Fax: +65 6741 2995 www.siata.com.sg Aqua Ionic 24 di 24...