Ikegami OCP-100 Operation Manual page 12

Operation
Table of Contents

Advertisement

1-4
1. NAME and FUNCTION
- SHUTTER switches
When the SHUTTER ON/OFF switch is pressed, the lamp lights and the preset shutter mode is set and the electronic
shutter starts working. When the switch is pressed again, the lamp goes off and the electronic shutter also stops operating.
While the electronic shutter is operating, the shutter speed will be displayed on the LED display. Select the shutter speed
using the UP/DOWN switches.
Pressing the VARIABLE SHUTTER switch sets the variable shutter mode. The VARIABLE indicator lights up and the
shutter speed is displayed on the LED display. The shutter speed can be selected using the UP/DOWN switches.
- GAIN switch
Select Master Gain using the UP/DOWN switch. One of the following values can be selected: -3, 0, +3, +6, +9, +12, +18,
+24, +20, +36, +42, or +48dB. The LED display indicates the current Gain setting value. Normally, set to "0".
Note:
The range of configurable gains varies, depending on the type of the connected camera.
10 FILTER switches
Use the switches to select a position of each fi lter. When the HEAD indicator is on, it indicates that the camera head is has
control, and control from the OCP is disabled. If the switch is pressed in this mode, the switch lamp starts fl ashing. Pressing
both fl ashing switches simultaneously shifts control from the camera head to the OCP. To shift control from the OCP to the
camera head, also press both switches simultaneously.
11 SCENE FILE switches
Sets and reads scene fi les 1 to 8. Files No. 1 to No. 4 and No. 5 to No. 8 can be switched by the toggle switch on the left of the
STORE switch.
Set
: Press the STORE switch, and then press the fi le number (1 to 8) to be set.
Read
: Press the fi le number to be read.
12 MODE switches/VR controls
- DTL/GAMMA controls
Used to control the DTL and GAMMA levels.
- VAR C. TEMP/COLOR SAT controls
Used to control the VAR. C. TEMP and COLOR SAT levels.
- KNEE POINT/SLOPE controls
Used to control the KNEE SLOPE and POINT manually.
- COLOR SAT switch
Used to turn ON/OFF the color saturation control.
- M. GAIN CONT switch
This is a switch for setting the Analog G GAIN control to master gain or to G gain. By setting the switch to "ON", the
master gain is selected, or by setting it to "OFF", the G gain is selected.
- AUTO KNEE switch
Used to set the AUTO KNEE mode.
OCP-100
DOWN
LED Display
100
Shutter Speed
1/100 sec 1/120 sec 1/250 sec 1/500 sec 1/1000 sec 1/2000 sec
SLOPE
POINT
OCP-100 1209 VOL1 (U) (E)
120
250
500
1000
UP
2000

Advertisement