TUNING
Enter the 6 digit code to proceed to settings.
SERVICE
Hydraulics
The following components can be adjusted:
C1-C4, C1/C2
Rotation
Outriggers/dozer blade
Track L
Track R
Tool
Boom pressure
Auto adjust
The selection "Reset system settings" resets all values to their basic setting.
Auto adjust
SERVICE
For auto adjustment, the machine should be standing on the outriggers and the tool should be disconnected.
Choose to calibrate "pressure and valves" or just "pressure". Valve calibration will improve the control of machine
movements. Pressure calibration will improve the accuracy of hydraulic pressure levels.
The machine will make small movements during valve calibration, which is normal.
"Pressure" will only calibrate pressure control function, without making any changes to customer specific tuning of
valves.
To start auto adjustment:
Start the motor.
Activate the machine.
Push right joystick forward, until calibration is completed.
Ramp up/down
Ramp adjusts the acceleration of the drive.
A high up-value means slow acceleration.
A low up-value means quick acceleration.
A high down-value means slow braking.
A low down-value means quick braking.
SETTINGS
Enter code
_ _ _ _ _ _
TUNING
1
3
Back
TUNING
HYDRAULICS
Hydraulics
Machine type
2
Languages
4
OK
Back
Auto adjust
Put outriggers down
Pressure and valves
and disconnect tool.
Activate and push right
joystick forward until
calibration is completed.
Pressure
Back
Joystick
Mating Bluetooth®
radio modules
Units
Terminal Diagnostics