Basic Parameters - Delta C2000 series User Manual

Classical field oriented control ac motor drive
Hide thumbs Also See for C2000 series:
Table of Contents

Advertisement

01 Basic Parameters

Pr.
01-00
Max. Operation Frequency
01-01
Output Frequency of Motor 1
01-02
Output Voltage of Motor 1
01-03
Mid-point Frequency 1 of Motor 1
01-04
Mid-point Voltage 1 of Motor 1
01-05
Mid-point Frequency 2 of Motor 1
01-06
Mid-point Voltage 2 of Motor 1
01-07
Min. Output Frequency of Motor 1
01-08
Min. Output Voltage of Motor 1
01-09
Start-Up Frequency
01-10
Output Frequency Upper Limit
01-11
Output Frequency Lower Limit
01-12
Accel. Time 1
01-13
Decel Time 1
01-14
Accel Time 2
01-15
Decel Time 2
01-16
Accel Time 3
01-17
Decel Time 3
01-18
Accel Time 4
01-19
Decel Time 4
01-20
JOG Acceleration Time
01-21
JOG Deceleration Time
Explanation
Chapter 11 Summary of Parameter SettingsC2000 Series
Settings
50.00~600.00Hz
0.00~600.00Hz
230V: 0.0V~255.0V
460V: 0.0V~510.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
0.00~600.00Hz
0.00~600.00Hz
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
11-7
Factory
Setting
60.00/
50.00
60.00/
50.00
200.0
400.0
3.00
11.0
22.0
0.50
2.0
4.0
0.00
0.0
0.0
0.50
600.00
0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C2000 series and is the answer not in the manual?

Questions and answers

Andrew Matthews
February 27, 2025

What does the STO fault code mean for a Delta C2000+?

User image 67c0809a8d55b
1 comments:
Mr. Anderson
February 27, 2025

The STO fault code on a Delta C2000+ indicates that the Safe Torque Off (STO) function has been activated. This is a safety feature that cuts power to the motor in case of an emergency stop. The fault occurs when the VFD detects that the STO input terminals (STO1 and STO2) are open circuit (not receiving voltage). Possible causes include wiring issues, such as loose connections or damaged wires, or an internal fault within the VFD.

This answer is automatically generated

charles seargeant
April 17, 2025

this unit was on the machine connected when i bought the machine . it has a problem and we know nothing about this unit. its making my machine quit running and all funtions go to zero. how can we disconnect it and run machine without it ? need help !

Table of Contents

Save PDF