The wall sensor tap kit comes standard with a sensor panel with a fixed aerated spout, a 1/2” solenoid valve, a sensor panel bracket, and a 24 AC volt power pack. For ENM5072, choose either 205mm or 250mm spout. Call 1300 369 273 www.enware.com.au...
6, 9, 12, 15 seconds Flow (Factory set at 6 sec) *Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
Any bright lighting reflecting off a highly reflective surface such as a stainless steel sink, or a high visibility reflective vest, may also interfere with correct sensor operation. www.enware.com.au Call 1300 369 273...
Page 6
• The solenoid valve and power point/ power lead extension from Enware, as this will pack is generally located either in the ceiling void warranty. space or in the wall but they must be easily accessible for servicing purposes.
Page 7
193mm wide x 115mm high rectangular hole in wall, at least 65mm deep to allow for installation COVER PLATE of bracket. WALL CUT OUT OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DEPTH) Installing the sensor bracket www.enware.com.au Call 1300 369 273...
1.8 metre lead from the sensor to the solenoid. Additional lead lengths up to 6 metres can be accommodated with extension cables WARNING: (available separately from Enware). Do not cut the electrical cable of the sensor tap, or alter the product in any way to suit installation.
Page 9
Time-Flow: Simply place your hand in front of sensor, and activate the sensor. For more details on sensor functions, refer to “Sensor Program”. www.enware.com.au Call 1300 369 273...
The powerpack is a non serviceable component. If damaged, the powerpack must be replaced. CLEANING Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals.
Page 12
Take note of the order of parts assembled. SEE IMAGES 10, 11, 12 57.5 SPACE FOR 4. Check seat and diaphragm for debris or any damage. CIRCUIT BOARD (REQUIRES 30mm DEPTH) SEE IMAGE 12 IMAGE 12 Call 1300 369 273 www.enware.com.au...
Page 13
COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DIRECTION OF FLOW DEPTH) IMAGE 16 COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DIRECTION OF FLOW DEPTH) IMAGE 17 www.enware.com.au Call 1300 369 273...
Page 14
Reconnect sensor to power supply and install the sensor back onto wall. COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DEPTH) IMAGE 18 Call 1300 369 273 www.enware.com.au...
Put hand in front of sensor to turn on, the water flows for the set period of time, then turns off automatically. Water flows for the set period of time regardless of any further hand movement. Default time setting from factory is 6 seconds for Time Flow (EMW804, ENM5071). www.enware.com.au Call 1300 369 273...