enware ENMATIC 5000 SERIES Installation And Maintenance Instructions Manual

Wall sensor tap hands free

Advertisement

Quick Links

ENMATIC 5000 SERIES
WALL SENSOR TAP HANDS FREE
Installation and Maintenance Instructions
ENM5071-205
Wall Sensor Tap
Time Flow Stainless Steel Sensor Panel
Mains Powered with 205mm Spout
ENM5072-205
ENM5072-250
Wall Sensor Tap
Wave-On Wave-Off Stainless Steel Sensor Panel
Mains powered with 205mm or 250mm Spout
I00024_Oct 17
Call 1300 369 273
www.enware.com.au
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: +61 2 8556 4000 Fax: +61 2 8556 4055

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENMATIC 5000 SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for enware ENMATIC 5000 SERIES

  • Page 1 ENMATIC 5000 SERIES WALL SENSOR TAP HANDS FREE Installation and Maintenance Instructions ENM5071-205 Wall Sensor Tap Time Flow Stainless Steel Sensor Panel Mains Powered with 205mm Spout ENM5072-205 ENM5072-250 Wall Sensor Tap Wave-On Wave-Off Stainless Steel Sensor Panel Mains powered with 205mm or 250mm Spout...
  • Page 2: Product Description

    The wall sensor tap kit comes standard with a sensor panel with a fixed aerated spout, a 1/2” solenoid valve, a sensor panel bracket, and a 24 AC volt power pack. For ENM5072, choose either 205mm or 250mm spout. Call 1300 369 273 www.enware.com.au...
  • Page 3: Dimensions (Not To Scale)

    1/2" BSP Bracket EMS804 Solenoid 2 m LONG CABLE COVER PLATE OUTLINE 57.5 2 m LONG 3 PIN FEMALE SPACE FOR CABLE CONNECTOR CIRCUIT BOARD SPADE TO SENSOR (REQUIRES 30mm CONNECTORS DEPTH) TO SOLENOID EMS805 Transformer www.enware.com.au Call 1300 369 273...
  • Page 4: Technical Data

    6, 9, 12, 15 seconds Flow (Factory set at 6 sec) *Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
  • Page 5: Installation

    Any bright lighting reflecting off a highly reflective surface such as a stainless steel sink, or a high visibility reflective vest, may also interfere with correct sensor operation. www.enware.com.au Call 1300 369 273...
  • Page 6 • The solenoid valve and power point/ power lead extension from Enware, as this will pack is generally located either in the ceiling void warranty. space or in the wall but they must be easily accessible for servicing purposes.
  • Page 7 193mm wide x 115mm high rectangular hole in wall, at least 65mm deep to allow for installation COVER PLATE of bracket. WALL CUT OUT OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DEPTH) Installing the sensor bracket www.enware.com.au Call 1300 369 273...
  • Page 8: Wiring Method

    1.8 metre lead from the sensor to the solenoid. Additional lead lengths up to 6 metres can be accommodated with extension cables WARNING: (available separately from Enware). Do not cut the electrical cable of the sensor tap, or alter the product in any way to suit installation.
  • Page 9 Time-Flow: Simply place your hand in front of sensor, and activate the sensor. For more details on sensor functions, refer to “Sensor Program”. www.enware.com.au Call 1300 369 273...
  • Page 10: Troubleshooting

    Solenoid service kit (1/2” AC) ENMS229 Spout Aerator (8 Lpm, Standard M22 -1) SP301 Fixing screw for sensor plate (Security M4x25 CSK Screw) 672480 Spout base O-ring (BS 119) 672352 “-205” Spout Only SPC203 “-250” Spout Only SPC250 Call 1300 369 273 www.enware.com.au...
  • Page 11: Service And Maintenance

    The powerpack is a non serviceable component. If damaged, the powerpack must be replaced. CLEANING Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals.
  • Page 12 Take note of the order of parts assembled. SEE IMAGES 10, 11, 12 57.5 SPACE FOR 4. Check seat and diaphragm for debris or any damage. CIRCUIT BOARD (REQUIRES 30mm DEPTH) SEE IMAGE 12 IMAGE 12 Call 1300 369 273 www.enware.com.au...
  • Page 13 COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DIRECTION OF FLOW DEPTH) IMAGE 16 COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DIRECTION OF FLOW DEPTH) IMAGE 17 www.enware.com.au Call 1300 369 273...
  • Page 14 Reconnect sensor to power supply and install the sensor back onto wall. COVER PLATE OUTLINE 57.5 SPACE FOR CIRCUIT BOARD (REQUIRES 30mm DEPTH) IMAGE 18 Call 1300 369 273 www.enware.com.au...
  • Page 15: Sensor Range

    Put hand in front of sensor to turn on, the water flows for the set period of time, then turns off automatically. Water flows for the set period of time regardless of any further hand movement. Default time setting from factory is 6 seconds for Time Flow (EMW804, ENM5071). www.enware.com.au Call 1300 369 273...
  • Page 16 Except as provided or referred to in this document, we of the Enware Australia Pty Limited, 9 Endeavour Road, accept no other or further liability for any damages Caringbah NSW 2229. We can also be contacted by...

Table of Contents