6 Servicing procedures
6.2 Troubleshooting
6.2.1 Error codes
Errors and required responses
The following table lists the errors that you may be able to resolve yourself. If the combi steamer con‐
tinues to display the error after you have tried to resolve it, please contact customer service.
Always contact customer service for help if any error messages appear that are not listed here.
Error no.
E01.x
E02
E05
E10
E34.0
E58.0
E59.0
E81.0
E99
E99.9
User manual
Description of error
Low water
Temp. electrical area too high
no gas
Error from water filter
Boiler pump error
Error from cleaning-agent dispensing
pump
Error from rinse-aid dispensing pump
Cooking mode error
Communication lost
Initialization error
Required response
Switch on water supply / both water
supplies
Clean the fan grille located outside at
■
the bottom of the appliance
Clear air intake in base of appliance
■
Open the gas shut-off device and re‐
start the appliance
Replace the water treatment cartridge
Unplug the appliance for approx.
10 seconds then restart
Fill canister with the correct cleaning
■
agent and restart the appliance
Repeat as necessary until the tubes
■
are filled with cleaning agent
Fill canister with rinse aid and restart
■
the appliance
Repeat as necessary until the tubes
■
are filled with rinse aid
Download cooking profile again
Unplug the appliance for approx.
10 seconds then restart
Unplug the appliance for approx.
10 seconds then restart