Safety Information; Operating Instructions - Kobalt KRC 60-06 User Manual

40 v lithium-ion charger
Table of Contents

Advertisement

SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS
instructions.
Be sure voltage selector is in correct voltage position before plugging in.

OPERATING INSTRUCTIONS

1. Charging procedure
Note: The battery is not shipped fully charged. It
ensure that maximum run time can be achieved.
This lithium-ion battery will not develop a memory
and may be charged at any time. A fully discharged
battery pack will require approximately 60 minutes
(2Ah) / 120 minutes (4Ah) to fully charge from a
discharged state.
Plug the charger into an AC power outlet.
Insert the battery into the charger.
This is a diagnostic charger. The charger LED lights
current battery status. They are as follows:
Charging
LED STATUS
Blinking Green
Solid Green
Solid Red
Blinking Red
False defect note:
When the battery is inserted into the charger and the status LED is blinking Red, remove the battery
from the charger for 1 minute, then reinsert. If the status LED is blinking Green, then the battery pack is
good. If the status LED is still blinking Red, remove the battery pack and unplug the charger. Wait 1
minute and plug the charger back in and reinsert the battery pack. If the status LED indicates blinking
Green, then the battery pack is good. If the status LED is still blinking Red, the battery pack is defective
and needs to be replaced.
WARNING
If the battery is inserted into the charger when warm or hot, the charging LED indicator light on the
charger may switch on and illuminate Red. If this occurs, allow the battery to cool outside of the charger
from approximately 30 minutes.
Fully
Over
Charged
Temperature
DESCRIPTION
Charging
Fully Charged
Over Temperature
Charging Fault
1
Charging
Fault
3
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KRC 60-06 and is the answer not in the manual?

Questions and answers

Table of Contents